M2series_ServiceManual_e.pdf - 第41页

3 Mechanical Section 3-9 Nozzle When obstacles such as solder paste are stuffed up in the nozzle, the suction b ecomes weak. And existence of an obstacle at the nozzle tip prevents the vision processing from recognizing …

100%1 / 92
3 Mechanical Section
3-8
Checking the nozzle for clogging
With nozzles placed in the head, turn ON the suction to check the air pressure. “Nozzle clog criteria” has
been set for each nozzle. The air pressure must be below the criteria. If it is not, the nozzle will be
considered to be clogged and an error will occur. (The “standard open value” given in the table below is
obtained from measurement of the open value of each nozzle (brand new nozzle) and must be used as a
reference.)
Standard open value (reference) Nozzle clog criteria
Nozzle type
(mmHg) (MPa) (mmHg) (MPa)
N001
N031
590630 0.0770.084
640 0.085
N002
N032
430520 0.0630.068
540 0.069
N003
285335 0.0430.048
420 0.056
N004
7090 0.0090.012
350 0.047
N005 40 or less 0.0053 or less 300 0.040
N006 40 or less 0.0053 or less 300 0.040
N012
240265 0.0320.035
270 0.036
N013
6585 0.0090.011
270 0.036
N017
380410 0.0510.055
470 0.063
N018
7090 0.0090.012
300 0.040
N019
7090 0.0090.012
300 0.040
N020 40 or less 0.0053 or less 300 0.040
N021
430520 0.0630.068
540 0.069
N022
430520 0.0630.068
540 0.069
NOTE: 1mmHg=133.322Pa=0.00013332MPa
3 Mechanical Section
3-9
Nozzle
When obstacles such as solder paste are stuffed up in the nozzle, the suction becomes weak. And existence
of an obstacle at the nozzle tip prevents the vision processing from recognizing smaller components. Clean
nozzles to avoid these troubles.
Nozzle Cleaning with Air Blow
Clean the nozzle tips with alcohol and then blow away dust with a blower (more than once a week). When
choking error occurs, also do the cleaning of the nozzle.
Be careful not to apply alcohol to identification marks. Quickly wipe off if
applied.
Nozzle Cleaning using Wire (1)
Normally, cleaning with the air blow may be enough. But when the dirt is firmly fixed, clean the nozzle
using a wire.
NOTE: To clean the nozzle using a wire, the O-ring and the nozzle filter inside the nozzle must be removed first.
Cleaning the nozzle with a wire without removing them may result in the damage or loss of them. After the
nozzle is cleaned, make sure to re-install them using a special tool.
NOTE: For a description of how to remove/install the O-ring and nozzle filter, refer to “Removing O-ring and
Nozzle filter” and “Attaching O-ring and Nozzle filter” given later in this manual.
Take care not to get injured with the fine wire when cleaning the nozzle.
ACTION:
Have a wire ready.
(300mm length, 0.1mm diam. Part No. KV8-M8887-00X)
Remove the O-ring and nozzle filter from the nozzle.
Pass the wire through the nozzle hole.
Wire
Nozzle
3 Mechanical Section
3-10
Wind to fasten the wire between both sides of the nozzle cleaner assy.
(Part No. KV8-M8881-A0X)
Nozzle Cleaner
Assy.
Move the nozzle back and forth to clean the nozzle hole.
Remove the wire and blow some air into the nozzle hole.
Nozzle Cleaning using Wire (2)
You can use the wire by fastening the wire ends with adhesive tape. In this case, adhesive may remain on
the wire. So be sure to clean the wire end before pulling out the wire from the nozzle.
Adhesive Tape