3 Technical data and assemblie s User manual SIPLACE TX-Series 3.5 Placement head From software version 713.0 Edition 01/2020 124 3.5.2 Sensor for the component reject bin The sensor for the compo nent reje ct bin monito…

100%1 / 346
User manual SIPLACE TX-Series 3 Technical data and assemblies
From software version 713.0 Edition 01/2020 3.5 Placement head
123
3.5.1.3 Technical data for SIPLACE SpeedStar (C&P20 M2) on SIPLACE TX micron
3
SIPLACE SpeedStar (C&P20 M2)
With component camera type
48
(Standard)
With component
camera type 49
(Optional)
Component range
*a
*)a Please note that the placeable component range is also affected by the pad geometry, the customer-specific
standards, the component packaging tolerances and the component tolerances.
0.12 mm x 0.12 (0201 metric) to 2220, Melf, SOT, SOD, Bare-
Die, Flip-Chip
Component spec.
Max. height
Min. lead pitch
Min. lead width
Min. ball pitch
Min. ball diameter
Min. dimensions
Max. dimensions
Max. weight
4 mm
70 µm
30 µm
100 µm
50 µm
120 µm x 120 µm
6 mm x 6 mm
1 g
4 mm
*b
50 µm
25 µm
50 µm
25 µm
80 µm x 80 µm
6 mm x 6 mm
1 g
*)b Due to the small area of focus of ±0.3 mm, this camera is only recommended if this particular camera res-
olution is required for the components. The nozzle length needs to be adjusted in accordance with the area
of focus and component thickness. The maximum component size for use remains 6 mm x 6 mm.
Set-down force Touchless Placement, 0.5 N, 1 N to 4.5 N
Nozzle types 40xx 40xx
X/Y accuracy
*c
With "accuracy class"
*d
Without "accuracy class"
*)c The accuracy values fulfill the conditions in the ASM scope of supply and services.
*)d Setting in SIPLACE Pro Component Shape Editor.
± 15 µm/3σ
*e
± 20 µm/3σ
± 20 µm/3σ
*)e Only with SIPLACE TX2i micron 15µm accuracy class
± 15 µm / 3σ
e
± 20 µm/3σ
± 20 µm/3σ
Angular accuracy ± 0.3° / 3σ
*f
± 0.2° / 3σ
*g
*)f For SIPLACE TX micron with accuracy class 25 µm
*)g For SIPLACE TX micron with accuracy class 20 µm or SIPLACE TX2i micron 15µm
± 0.3° / 3σ f
± 0.2° / 3σ
g
Illumination level 5 5
3 Technical data and assemblies User manual SIPLACE TX-Series
3.5 Placement head From software version 713.0 Edition 01/2020
124
3.5.2 Sensor for the component reject bin
The sensor for the component reject bin monitors whether the reject bin is seated correctly in its
mount.
If the reject bin was not inserted correctly, the placement machine cannot be started.
If the reject bin jumps out of its mount during the placement process, the placement machine
will be stopped immediately to avoid a head crash.
3.5.3 Vacuum pump (optional)
The vacuum pump for the SIPLACE SpeedStar is fitted behind the cover at location 1, in the ma-
chine frame.There are two types available:
Vacuum pump VX4.25
Vacuum pump VX4.25/0-47 IE3
3.5.3.1 Overview - type VX4.25
Item no. 03128463-xx Vacuum pump VX4.25
3
Fig. 3.5 - 2 Overview - vacuum pump
(1) Installation location for vacuum pump
(2) Vacuum pump VX 4.25
(2)
(1)
User manual SIPLACE TX-Series 3 Technical data and assemblies
From software version 713.0 Edition 01/2020 3.5 Placement head
125
3.5.3.2 Overview - type VX4.25/0-47 IE3
Item no. 03224400-xx Vacuum pump VX4.25/0-47 IE3
3
Fig. 3.5 - 3 Overview - vacuum pump
(1) Installation location for vacuum pump
(2) Vacuum pump VX 4.25 IE3
3.5.3.3 Safety instructions for vacuum pumps
3
(2)
(1)
WARNING
Please observe the safety instructions in the vacuum pump instruction manual sup-
plied.