00197975-06_UM_TX-Serie_EN - 第312页
6 Station extensions User manual SIPLACE TX-Series 6.8 IPC-Hermes-9852 From software version 713.0 Edition 01/2020 312 6.7.2.2 T echnical dat a 6 6.8 IPC-Hermes-9852 IPC-HERMES-9852 is a communicati on protocol for SMT l…

User manual SIPLACE TX-Series 6 Station extensions
From software version 713.0 Edition 01/2020 6.7 Stationary cameras
311
6.7.2 Component camera, stationary P&P, type 33, 55 x 45, digital
Item no. 00588100-xx Stationary camera for the CPP head, type 33
6
Fig. 6.7 - 2 Structure for the stationary P&P component camera, type 33, 55 x 45, digital
(1) Camera housing with integral camera and camera amplifier
(2) Glass plate - illumination and lens levels below
6.7.2.1 Safety instructions
6
(1)
(2)
WARNING
Risk of collisions!
When changing the placement head from a TwinStar/VHF to a SpeedStar, the SpeedStar
collides with the camera housing.
Dismantle the stationary component camera for the TwinStar.
When changing the placement head from a TwinStar to a MultiStar, the stationary
component camera is fitted in the bottom position.

6 Station extensions User manual SIPLACE TX-Series
6.8 IPC-Hermes-9852 From software version 713.0 Edition 01/2020
312
6.7.2.2 Technical data
6
6.8 IPC-Hermes-9852
IPC-HERMES-9852 is a communication protocol for SMT lines and can replace the IPC SMEMA
interface. This protocol allows you to transfer more information than previously via the IPC
SMEMA interface.
This could be, for example:
– Unique board IDs
– Barcodes
– Conveyor speed,
– Board length and width
– Board thickness
– Transport clearance height
All this information can be transmitted along the whole line without interruption.
For a detailed description, see the Administrator Manual IPC-HERMES-9852, item no.
[00198615-xx].
6
Component dimensions 0.5 mm x 0.5 mm to 55 mm x 45 mm
Component range 0402, MELF, SO, PLCC, QFP, electrolytic capacitors, BGA
Min. lead pitch 0.3 mm
Min. lead width 0.15 mm
Min. ball pitch 0.35 mm
Min. ball diameter 0.2 mm
Field of vision 65 mm x 50 mm
Illumination type Front-illumination (6 levels, programmable as required)

User manual SIPLACE TX-Series 6 Station extensions
From software version 713.0 Edition 01/2020 6.9 Support pin
313
6.9 Support pin
Item no. 00119680-01 Support pin
Wide boards tend to deflect during placement such that, under certain circumstances, the compo-
nents can no longer be placed with the desired accuracy. Highly curved PCBs also affect the
placement accuracy. This problem can be easily rectified by fitting support pins on the lifting table.
6
Fig. 6.9 - 1 Support pin
(1) Magnetic base
6
PLEASE NOTE
Make sure that the magnetic base of the Support Pin is not placed under the side wall of
the conveyor. This could lead to the side wall profile being damaged.
(1)