CAUTION
CAUTION
Decommissioning/
Disposal
Decommissioning prepares equipment for safe and secure transportation.
Laboratory Grade Ethylene glycol (EG) is poisonous and
ammable. Before disposing refer to the manufacturer’s most
current MSDS for handling precautions.
Decommissioning must be performed only by qualied dealer using
certied equipment. All prevailing regulations must be followed.
Consider decommissioning the chiller when:
It fails to maintain desired specications
It no longer meets safety standards
It is beyond repair for its age and worth
Refrigerant and compressor oil must be recovered from equipment before
disposal.
Note Keep in mind any impact your application may have had on the
chiller.
Direct questions about chiller decommissioning or disposal to our Sales,
Service and Customer Support.
Handling and disposal should be done in accordance with the
manufacturers specication and/or the MSDS for the material used.
WARNING
Shipment
Storage
Follow the manufacturer's MSDS instructions if decontamination is
required.
Transporting and/or storing the chiller in near or below freezing
temperatures requires draining, see Draining in this Section.
Store the chiller in the temperature range of -25°C to 60°C (with
packaging), and <80% relative humidity.
If the chiller is stored for more than 90 days it must be ushed with
clean uid before operating.
CAUTION
CAUTION
CAUTION
Section 8
8-12 ThermoFlex
Thermo Scientific
ThermoFlex A-1
Thermo Scientific
Appendix A Country Specific
230 VAC, 50 Hz, 1Ø Requirements
Refer to the nameplate label located on the rear of the chiller for specic
electrical requirements.
1. Chillers shipped to the following locations require a 16 Amp service:
Afghanistan, Albania, Algeria, Andorra, Angola, Argentina, Armenia,
Austria, Azerbaijan, Belarus, Belgium, Benin, Bolivia, Bosnia and
Herzegovina, Brazil, Bulgaria, Burkina Faso, Burundi, Cambodia,
Cameroon, Cape Verde, Central African Republic, Chad, Chile, Comoros,
Congo, Croatia, Czech Republic, Denmark, Djibouti, DR Congo,
Ecuador, Egypt, Eritrea, Estonia, Ethiopia, Finland, France, French
Guiana, Gabon, Georgia, Germany, Greece, Guinea, Hungary, Iceland,
Indonesia, Iran, Iraq, Israel, Italy, Ivory Coast, Jordan, Kazakhstan,
Kyrgyzstan, Latvia, Lebanon, Liberia, Libya, Liechtenstein, Lithuania,
Luxembourg, Madagascar, Mali, Mauritania, Moldova, Monaco,
Mongolia, Morocco, Mozambique, Namibia, Nepal, Netherlands, Niger,
North Korea, Norway, Paraguay, Peru, Poland, Portugal, Romania,
Russia, Rwanda, Saint Vincent and the Grenadines, San Marino, Sao
Tome and Principe, Saudi Arabia, Senegal, Serbia, Slovakia, Slovenia,
Somalia, South Africa, South Korea, Spain, Sweden, Switzerland, Syria,
Tajikistan, Thailand, Togo, Tunisia, Turkey, Turkmenistan, Ukraine,
Uruguay, Uzbekistan, Vanuatu, Vatican City, Vietnam.
2. Chillers shipped to the following locations require a 15 Amp service:
Australia, China, Fiji Islands, Nauru, New Zealand, Papua New Guinea,
Solomon Island, Tonga, Tuvalu.
3. Chillers shipped to the following locations require a 13 Amp service:
Abu Dhabi, Bahrain, Bangladesh, Botswana, Brunei, Cyprus, Dominica,
Gambia, Ghana, Gibraltar, Grenada, Hong Kong, India, Ireland, Kenya,
Kiribati, Kuwait, Lesotho, Malawi, Malaysia, Maldives, Malta, Mauritius,
Myanmar, Nigeria, Oman, Pakistan, Qatar, Saint Lucia, Seychelles, Sierra
Leone, Singapore, Sri Lanka, Sudan, Swaziland, Tanzania, Uganda,
United Arab Emirates, United Kingdom Yemen, Zambia, Zimbabwe.