Appendix A Country Specific
230 VAC, 50 Hz, 1Ø Requirements
Refer to the nameplate label located on the rear of the chiller for specic
electrical requirements.
1. Chillers shipped to the following locations require a 16 Amp service:
Afghanistan, Albania, Algeria, Andorra, Angola, Argentina, Armenia,
Austria, Azerbaijan, Belarus, Belgium, Benin, Bolivia, Bosnia and
Herzegovina, Brazil, Bulgaria, Burkina Faso, Burundi, Cambodia,
Cameroon, Cape Verde, Central African Republic, Chad, Chile, Comoros,
Congo, Croatia, Czech Republic, Denmark, Djibouti, DR Congo,
Ecuador, Egypt, Eritrea, Estonia, Ethiopia, Finland, France, French
Guiana, Gabon, Georgia, Germany, Greece, Guinea, Hungary, Iceland,
Indonesia, Iran, Iraq, Israel, Italy, Ivory Coast, Jordan, Kazakhstan,
Kyrgyzstan, Latvia, Lebanon, Liberia, Libya, Liechtenstein, Lithuania,
Luxembourg, Madagascar, Mali, Mauritania, Moldova, Monaco,
Mongolia, Morocco, Mozambique, Namibia, Nepal, Netherlands, Niger,
North Korea, Norway, Paraguay, Peru, Poland, Portugal, Romania,
Russia, Rwanda, Saint Vincent and the Grenadines, San Marino, Sao
Tome and Principe, Saudi Arabia, Senegal, Serbia, Slovakia, Slovenia,
Somalia, South Africa, South Korea, Spain, Sweden, Switzerland, Syria,
Tajikistan, Thailand, Togo, Tunisia, Turkey, Turkmenistan, Ukraine,
Uruguay, Uzbekistan, Vanuatu, Vatican City, Vietnam.
2. Chillers shipped to the following locations require a 15 Amp service:
Australia, China, Fiji Islands, Nauru, New Zealand, Papua New Guinea,
Solomon Island, Tonga, Tuvalu.
3. Chillers shipped to the following locations require a 13 Amp service:
Abu Dhabi, Bahrain, Bangladesh, Botswana, Brunei, Cyprus, Dominica,
Gambia, Ghana, Gibraltar, Grenada, Hong Kong, India, Ireland, Kenya,
Kiribati, Kuwait, Lesotho, Malawi, Malaysia, Maldives, Malta, Mauritius,
Myanmar, Nigeria, Oman, Pakistan, Qatar, Saint Lucia, Seychelles, Sierra
Leone, Singapore, Sri Lanka, Sudan, Swaziland, Tanzania, Uganda,
United Arab Emirates, United Kingdom Yemen, Zambia, Zimbabwe.
ThermoFlex B-1
Thermo Scientific
Appendix B Voltage Configuration Instructions
ThermoFlex 900 and 1400 chillers equipped with the 115V 60Hz, 100v 50/60Hz Variable Voltage option and
ThermoFlex 900 to 5000 chillers equipped with 200-230V 50/60Hz Global Voltage option have a voltage
conguration panel located on the rear of the chiller behind an access panel, see Figure B-1.
• Use a 1/4” socket to remove the four screws securing the access panel to the chiller.
• The conguration panel has two 3-position toggle switches, one for voltage and one for frequency. All chillers
are shipped with the toggle switch in the center SHIP position. Place each switch to the settings that match
the voltage/frequency supplied to the chiller.
Note For ThermoFlex900-2500 global voltage chillers, the compressor and fan will not operate when the
switch is in the SHIP position.
• Reinstall the access panel.
Access Panel for
900 - 2500 chillers.
Access Panel for
3500 - 5000
chillers.
Variable Voltage chillers
Global Voltage chillers
Figure B-1 Variable/Global Voltage Chillers