ThermoFlex-Manual - 第136页

W ARRANTY Ther mo Fisher Scientic warra nts for 24 months ( excluding MD 1/MD 2 Magn etic Driv e and P 1/P 2 Positi ve Displacement pumps which are w ar ranted f or 12 months ) from date of shipment the T her mo Scienti…

100%1 / 138
Laboratory Equipment Div.
25 Nimble Hill Road
Newington, NH 03801
D of C 094026.1 Form 094233
DWG # 094026 REV 17 Apr 07
DECLARATION OF CONFORMITY
Manufacturer: Thermo Fisher Scientific
Address: 25 Nimble Hill Road
Newington, NH 03801 USA
Products: Refrigerated chillers and heat exchangers. Year of inception 2008
We declare that the following products conform to the Directives and Standards listed below:
Unit has a 15 digit part number consisting of UU C VV PP c XXXXXXX defined as follows:
UU = Unit type can be:
10 = TF 900 11 = TF 1,400 12 = TF 2,500 13 = TF 3,500 14 = TF 5,000
15 = TF 7,500 16 = TF 10,000 17 = TF 15,000 18 = TF 20,000 19 = TF 24,000
C = Cooling type and Temperature Range and can be a 1-4 inclusive, where:
1 = Air Cooled Standard Temp ( 5-40°C ) 2 = Air Cooled Hi Temp ( 5-90°C )
3 = Water Cooled Standard Temp ( 5-40°C ) 4 = Water Cooled Hi Temp ( 5-90°C )
VV = Unit voltage rating:
UU = 10, 11, 12, 13 & 14 UU = 15, 16 & 17 UU = 18 & 19
10 = 115V, 60Hz 1Ph 17 = 200/208/230V, 60Hz 3Ph 17 = 208/230V, 60Hz 3Ph
100V, 50Hz 1Ph 200V, 50Hz 3Ph
11 = 100/115V, 60Hz 1Ph 18 = 400V, 50Hz 3Ph 18 = 400V, 50Hz 3Ph
100/115V, 50Hz 1Ph 20 = 200/208/230V, 60Hz 3Ph
12 = 208/230V, 60Hz 1Ph 200-230V, 50Hz 3Ph
200V, 50Hz 1Ph 21 = 460V, 60Hz 3Ph 21 = 460V, 60Hz 3Ph
16 = 230V, 50Hz 1Ph 400V, 50Hz 3Ph 400V, 50Hz 3Ph
20 = 200/208/230V, 60Hz 1Ph
200/230V, 50Hz 1Ph
PP = Pump type, can be 10 through 25 inclusive.
c = Unit controller type, can be any digit from 1-6, inclusive.
X = Any digit from 0-9, used as sequential numbering only.
Equipment Class: Measurement, control and laboratory
Directives and Standards:
2004/108/EC – Electromagnetic Compatibility ( EMC Directive ):
EN 61326-1: 2006 – Electrical equipment for measurement, control, and laboratory use – EMC requirements,
EMC Class A
2006/95/EC – Low Voltage Directive ( LVD ):
EN 61010-1: 2004 – Safety requirements for electrical equipment for measurement,
control, and laboratory use – general requirements.
EN 61010-2-010: 2003 Particular requirements for laboratory equipment for the heating of materials.
Additional EMC Evaluations with Certificates:
EN 61000-3-2: 2006 Harmonics
EN 61000-3-3: 2008 Flicker
Manufacturer’s Authorized Representative: Date:
__________________________ 15 September 2011
Robin Wiley Compliance Engineering
WARRANTY
Thermo Fisher Scientic warrants for 24 months (excluding MD 1/MD 2 Magnetic Drive and P 1/P 2
Positive Displacement pumps which are warranted for 12 months) from date of shipment the Thermo Scientic
ThermoFlex chiller according to the following terms.
Any part of the chiller manufactured or supplied by Thermo Fisher Scientic and found in the reasonable judgment
of Thermo Fisher to be defective in material or workmanship will be repaired at an authorized Thermo Fisher Repair
Depot without charge for parts or labor. The chiller, including any defective part must be returned to an authorized
Thermo Fisher Repair Depot within the warranty period. The expense of returning the chiller to the authorized
Thermo Fisher Repair Depot for warranty service will be paid for by the buyer. Our responsibility in respect to
warranty claims is limited to performing the required repairs or replacements, and no claim of breach of warranty
shall be cause for cancellation or recision of the contract of sales of any chiller. With respect to chillers that qualify
for eld service repairs, Thermo Fisher Scientic’s responsibility is limited to the component parts necessary for
the repair and the labor that is required on site to perform the repair. Any travel labor or mileage charges are the
nancial responsibility of the buyer.
The buyer shall be responsible for any evaluation or warranty service call (including labor charges) if no defects are
found with the Thermo Scientic product.
This warranty does not cover any chiller that has been subject to misuse, neglect, or accident. This warranty does
not apply to any damage to the chiller that is the result of improper installation or maintenance, or to any chiller
that has been operated or maintained in any way contrary to the operating or maintenance instructions specied in
this Instruction and Operation Manual. This warranty does not cover any chiller that has been altered or modied
so as to change its intended use.
In addition, this warranty does not extend to repairs made by the use of parts, accessories, or uids which are either
incompatible with the chiller or adversely affect its operation, performance, or durability.
Thermo Fisher Scientic reserves the right to change or improve the design of any chiller without assuming any
obligation to modify any chiller previously manufactured.
THE FOREGOING EXPRESS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTIES OR MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE.
OUR OBLIGATION UNDER THIS WARRANTY IS STRICTLY AND EXCLUSIVELY LIMITED TO THE
REPAIR OR REPLACEMENT OF DEFECTIVE COMPONENT PARTS AND Thermo Fisher Scientic DOES
NOT ASSUME OR AUTHORIZE ANYONE TO ASSUME FOR IT ANY OTHER OBLIGATION.
Thermo Fisher Scientic ASSUMES NO RESPONSIBILITY FOR INCIDENTAL, CONSEQUENTIAL, OR
OTHER DAMAGES INCLUDING, BUT NOT LIMITED TO LOSS OR DAMAGE TO PROPERTY, LOSS
OF PROFITS OR REVENUE, LOSS OF THE CHILLER, LOSS OF TIME, OR INCONVENIENCE.
This warranty applies to chillers sold in the United States. Any chillers sold elsewhere are warranted by the afliated
marketing company of Thermo Fisher Scientic. This warranty and all matters arising pursuant to it shall be governed
by the law of the State of New Hampshire, United States. All legal actions brought in relation hereto shall be led
in the appropriate state or federal courts in New Hampshire, unless waived by Thermo Fisher Scientic.