PSV7000_ Owners Manual_096-0460-001B - 第112页
Maintenance ■ Maintenance Schedule 4—6 Data I/O • 096-0640-001B back Note: Specific items ar e noted at each individual procedure. Generally R equired Items • Lens cleaning paper (Data I/O PN 570041) • W ater dampened cl…

■ Maintenance Schedule ◘ Materials Required
PSV7000 Owner’s Manual 4—5
back
Materials Required
To perform preventive maintenance procedures on the
PSV7000 System, in general you need the following materials.
Every quar-
ter
Safety doors Clean with damp cloth. —
Items to check Every Six Months
6-mos. PNP head Check; tighten if necessary. page
4-22
Every
6-mos. or as
needed
depending
on use
Laser Marking Sys-
tem*
Tiger Fume Extractor
Clean the nozzle and extraction tube.
Replace the Pre-Filter. . . . . . . . . .
Replace the Tiger main filter twice yearly, or whenever
the Tiger System alarm sounds and blinks the red lamp.
page
4-36
page
4-36
page
4-36
Every
6-mos.
Handler Computer Clean the Handler Computer air filter. page
4-41
Every
6-mos.
Laser Computer* Clean the Laser Computer air filter. page
4-39
Every
6-mos.
3D Inspection Com-
puter*
Clean the 3D Coplanarity Inspection Computer air fil-
ter.
page
4-43
Items to check Once a Year
Every year
Gantry
guide rails
(every 2 million
devices or one year,
whichever comes
first)
Clean and lubricate annually, or sooner if the gantry
becomes noisy.
page
4-22
Every year FlashCORE program-
mers
Run conformance verification test using Data I/O’s
DAB, part number 910-2200-003 or higher. Or have a
Data I/O Service Technician perform the test. Custom-
ers with an APS contract have some costs of the test
covered in the agreement.
page
4-28
Every year Vacuum Generator
silencers PNP head
Check vacuum generator silencers; replace as neces-
sary.
page
4-21
Every year
or as
needed
Gantry Belt Check Gantry belt tension.
Required: PSV7000 SELF-SERVICE SPARES KIT
page
4-23
Date
completed
/ initials
Component
Action
(see precautions also, on page listed)
Page
* denotes optional equipment

Maintenance ■ Maintenance Schedule
4—6 Data I/O • 096-0640-001B
back
Note: Specific items are noted at each individual procedure.
Generally Required Items
• Lens cleaning paper (Data I/O PN 570041)
• Water dampened cloth for cleaning
• Isopropyl alcohol
• Antistatic cleaner
• Dry, compressed air
• Safety goggles
• Disposable protective gloves
• Particle (dust) mask
•SAE and metric hex socket wrenches and hex keys (Allen
Wrenches). Data I/O hex key set PNs: Metric 565-0006-001, and
Standard 565-0007-001
• Screw driver sets, flat and Phillips
• Metric open end wrenches for the probe tips
• Shop vacuum cleaner
• Self-Serve Spares Kit (page 4-7)
Turning Off the System
When the PSV7000 System will not be used for several days, or before
performing a service procedure, turn OFF the system.
See Shutting Down the PSV7000 System on page 2-7.

■ Self-Service Spares Kit ◘ Turning Off the System
PSV7000 Owner’s Manual 4—7
back
Self-Service Spares Kit
The Self-Service Spares Kit, Data I/O part number 952-0508-001 or
higher, can be purchased at any time.
Some items the kit contains:
910-2200-00d or higher:
Diagnostics Adapter Board (DAB)
for programmer calibration
(Sales PN: FC-DIAGNOSTICS
BOARD)
565-0222-001 or higher:
Gantry Belt tension tool
750-2474-001 or higher:
an entire probe assembly
480-0070-001 or higher:
16-port VLAN Ethernet hub
750-2464-001 or higher:
programmer power supply
2940220001 or higher:
Pneumatic Silencer