Maintenance Troubleshooting
4—50 Data I/O • 096-0640-001B
back
Air Pressure Problems
Lamp
Color
Air Pressure Trouble Possible Resolutions
Red
There is no main air
pressure.
Make sure that the main air switch on the
Power Panel is in the ON position.
Check that the air regulator on the Power
Panel displays within the acceptable range:
PSV7000 Specifications on page 1-9.
If not:
• Check your shop air pressure.
• Shut down and replace the filter. See Replac-
ing the Input Air Filter on page 4-18.
The digital display on the regulator will be
green when air pressure is within the correct
range and red when it is out of range. The reg-
ulator has been set at the factory and is not
adjustable.
Red
There is no (or low)
vacuum on the PNP probes.
Check that the probes are not loose and that
the o-rings are not destroyed or leaking.
See Pick and Place Probes on page 4-14.
Determine if the PNP head probes are clogged.
Clean if necessary. Refer to Removing and
Installing a Probe in the PSV7000 Operators
Manual.
Check the probe vacuum and Blow-off sole-
noids; Adjusting the Vacuum Generator Sensors
on page 4-17.
Clean the vacuum generator filters and silenc-
ers; Vacuum Generator Filters and Silencers on
page 4-19
Troubleshooting Tube Input and Output Problems
PSV7000 Owner’s Manual 4—51
back
Tube Input and Output Problems
This information is subject to change.
Lamp
Color
Vibrator Tube Trouble Possible Resolutions
Neither of the tube
platforms vibrates.
Make sure that tube input or tube output has
been selected on the Setup window.
Check that the power switch at each Tube
Module is ON.
Make sure the vibration and frequency con-
trols are set properly.
Only one tube plat-
form vibrates.
Check that the power switch at each Tube
Module is ON.
Check the power cable source connection.
Check the fuse on the input module.
PSV7000 is putting the
wrong number of devices
into the output tubes.
Reset devices per tube in the Gantry window
as follows:
1. At the Setup window, Options tab, ensure that
Input and/or Output options are set to tubes.
2. Click System > Gantry (you may be prompted
to enter your password). Click the yellow Vib1
label to move the PNP head to the first posi-
tion of the input vibrator.
Figure 4-27: The Vib1 label has been clicked.
3. Click the Tubes tab, then enter the correct
number of devices per tube in the Chips/Tube
field.
4. Click Save to store the new settings to the
Package File.
Maintenance Troubleshooting
4—52 Data I/O • 096-0640-001B
back
Tray Feeder Problems
Handler Computer Failure
A Handler computer drive fails. A message or behavior indicates that
a computer has crashed.
Your PSV7000 System is equipped with a mirror-backup system
called RAID that creates a real-time ghost image. You will see an error
message display very quickly at system start-up.
Figure 4-28: This message, DEGRADED, will display for about seven
seconds at startup if a Handler drive has failed.
Your PSV7000 System will continue to operate as normal on the
backup drive. However, the failed drive must be replaced for con-
tinued safety. After the failed drive is identified and replaced, the
message on-screen will read REBUILDING. After it has rebuilt, the
next time you start up it will read NORMAL.
Contact Data I/O Support or your nearest Data I/O representative.
Lamp
Color
Tray Feeder Trouble Possible Resolutions
Yellow
The Run window indi-
cates a tray is present on the
Data I/O Dual Tray Feeder
when there is no tray there,
or vice versa.
Navigate to the System > MISC I/O window
and verify that the Tray Present Sensor = ON.
Probes miss-pick or
misplace devices at the trays.
Probes hit devices in a
tray hard at one end and not
the other.
Check that the tray feeder is level. Adjust the
outside mounting bar if necessary.