PSV7000_ Owners Manual_096-0460-001B - 第54页

Setup ■ Setting Up Input and Output Media 2—16 Data I/O • 096-0460-001B back Figure 2-11: Connection for the Data I/O Dual T ray F eeder: electrical, Ethernet, and air (left to right). 12. Re-attach the utilities cover .…

100%1 / 186
Setting Up Input and Output Media Setting Up an Automatic Tray Feeder
PSV7000 Owner’s Manual 2—15
back
Figure 2-9: The Data I/O Dual Tray Feeder mounting bars (arrows).
Views from the back of the machine. (Note that the shield has not been
rotated out of the way in this image.)
9. Screw in two screws (5 mm hex key) into each of the two mount-
ing bars to secure the feeder.
10. Remove the utilities connection cover; two screws (2.5 mm hex
key).
11. Plug in the three utilities: air, electrical, and ethernet.
The air connection is a One-Touch fitting.
Rotate the electrical connector until it slides into the socket, then
screw the ring up.
Figure 2-10: The Data I/O Dual Tray Feeder utilities connection cover
has two screws (circled). The Ethernet cable is not connected in this
view.
Utilities cover is removed
Utilities Cover
Refer to the following
two figures for Tray
Feeder connections.
Setup Setting Up Input and Output Media
2—16 Data I/O • 096-0460-001B
back
Figure 2-11: Connection for the Data I/O Dual Tray Feeder: electrical,
Ethernet, and air (left to right).
12. Re-attach the utilities cover.
Very basic operating instructions are covered in the PSV7000 Opera-
tors Manual. Complete instructions are covered in the Data I/O Dual
Tray Feeder Owners Manual.
Tray Arrangements
You can use a spare tray with an Automatic Tray Feeder (ATF). When
tray position two is designated as a spare static tray, the devices from
that spare tray are used to replace rejected devices. They are also
used during a tray change.
For possible configurations, see the chart on the following page.
A ‘spare tray’ is also
referred to as an ‘aux-
iliary static tray.’
Setting Up Input and Output Media Setting Up an Automatic Tray Feeder
PSV7000 Owner’s Manual 2—17
back
Figure 2-12: Possible Input/Output layouts with an Automatic Tray
Feeder. A reject bin could be used instead of a tray.
Remember that
•the Setup window > Options tab must be set to match the work-
space setup (covered in the Operators Manual).
The Package File must be taught the location of the Reject con-
tainer (covered in Chapter 3 of this manual).
(Optional) If the Sort-On-Error-Code is used, two Reject Bins are
required. Set up for Sort-On-Error-Code by installing a second
Reject Bin.
For more about
Sort-On-Error-Code, see
Monitoring Statistics on
page 3-12.