Administrative Functions ■ Administrator Functions 3—16 Data I/O • 096-0460-001B back 2. Locate the section for SPC Logging. It will look like this: [SPC Logging] LoggingEnabled=FALSE MaxFileSize=10485760 TempLogFile=C:\…

100%1 / 186
Administrator Functions Monitoring Statistics
PSV7000 Owner’s Manual 3—15
back
To reset Package statistics:
1. Select Package Statistics in the drop-down field in the upper left
corner.
2. Click Reset in the right-most column corresponding to the Flash-
CORE programmer on which the Socket Adapter was replaced.
If a Socket Adapter was replaced, reset all rows for that pro-
grammer.
If an individual socket was replaced*, reset only the row corre-
sponding to the replaced socket.
The R-date (reset date) is set to the current date and statistics are
all reset to zero.
Figure 3-8: Resetting Package statistics. Open the Statistics window
from either the Setup window or the Run window.
Statistical Process Control Software
The AH700 can be set to generate a semicolon-delimited file whose
fields are described on the next page. A (customer-supplied) Statis-
tical Control SW can be used to import and process data output by
the AH700. Or use Data I/O’s Enhanced Statistical Software that
comes with the A
H700; see page 3-34
.
CAUTION: File corruption hazard! Before making any changes to
your winAH400.ini file, save a backup copy.
To generate a semicolon-delimited output file:
1. On the Handler Computer, navigate to C:\AH700 and open
winAH400.ini (with Microsoft® Notepad or IDM Computer
Solutions’s UltraEdit®).
*Only HIC Socket
Adapters and HPS
Socket Adapters are
designed to accommo-
date replacement of
individual sockets on
the adapter board.
Administrative Functions Administrator Functions
3—16 Data I/O • 096-0460-001B
back
2. Locate the section for SPC Logging. It will look like this:
[SPC Logging]
LoggingEnabled=FALSE
MaxFileSize=10485760
TempLogFile=C:\spcout.txt
3. Set the second line (LoggingEnabled) to TRUE.
4. (Optional) Edit the location of the output file at the line
“TempLogFile=...” entering the drive and path desired.
5. Save and close winAH400.ini.
Note: In the above example the SPC logging file is saved to
C:\
directory. It can, however, be saved elsewhere on the Handler Com-
puter hard drive, or on a networked drive if network connected.
The SPCOut.txt file contains semicolon-delimited fields. A partial list
follows:
The SPCOut.txt Field Descriptions
01 DevicesInputsystem - number of devices picked from Input
media
02 DevicesInspected - number of devices inspected by Vision system
03 InspectionQuality* - as percentage, compared with reference
vision
04 InspectionYield
05 DevicesInsertedSocket - number of devices inserted into socket
06 SocketYield
07 ProgrammerYield
08 ProgSysYield - Yield of all programmers together
09 DevicesProcessedMarker
10 MarkingYield
11 SystemThroughputExcWait - starts with first device placed,
excludes wait times.
12 SystemTotalThroughputIncWait - starts when Run starts,
includes wait times
13 SystemYield
14 AreaID - Programmer #1 = “17”, Programmer #2 = “18”, …, Pro-
grammer #24 = “40”)
15 PosID - that is Socket #
16 TimeStamp - Date/Time of SPC log entry
17 OrderNumber - Job Name and or number
Administrator Functions Monitoring Statistics
PSV7000 Owner’s Manual 3—17
back
If the Automotive Performance Pak is installed, an extended SPC log
file (with APP enabled) would have the following delimited fields:
18 Package - A Package File used for the job
TimeStamp
JobName
JobDescription
Device
Package
VisionPRJ
RecordID
SystemStatus
SystemMSG
FromAreaID
FromPosID
DeviceStatus
WhichCup
SNused
ToAreaID
ToPosID
DevicesInspected
InspectionPassed
InspectionQuality
DevicesInserted-
Socket
SocketYield
ProgrammerYield
ProgSysYield
The SPCOut.txt Field Descriptions