PSV7000_ Owners Manual_096-0460-001B - 第87页
■ Administrator Functions ◘ Monitoring Statistics PSV7000 Owner’s Manual 3—17 back If the Automotiv e P erformance P a k is installed, an extended SPC log file (with APP enabled) would have the following delimited fields…

Administrative Functions ■ Administrator Functions
3—16 Data I/O • 096-0460-001B
back
2. Locate the section for SPC Logging. It will look like this:
[SPC Logging]
LoggingEnabled=FALSE
MaxFileSize=10485760
TempLogFile=C:\spcout.txt
3. Set the second line (LoggingEnabled) to TRUE.
4. (Optional) Edit the location of the output file at the line
“TempLogFile=...” entering the drive and path desired.
5. Save and close winAH400.ini.
Note: In the above example the SPC logging file is saved to
C:\
directory. It can, however, be saved elsewhere on the Handler Com-
puter hard drive, or on a networked drive if network connected.
The SPCOut.txt file contains semicolon-delimited fields. A partial list
follows:
The SPCOut.txt Field Descriptions
01 DevicesInputsystem - number of devices picked from Input
media
02 DevicesInspected - number of devices inspected by Vision system
03 InspectionQuality* - as percentage, compared with reference
vision
04 InspectionYield
05 DevicesInsertedSocket - number of devices inserted into socket
06 SocketYield
07 ProgrammerYield
08 ProgSysYield - Yield of all programmers together
09 DevicesProcessedMarker
10 MarkingYield
11 SystemThroughputExcWait - starts with first device placed,
excludes wait times.
12 SystemTotalThroughputIncWait - starts when Run starts,
includes wait times
13 SystemYield
14 AreaID - Programmer #1 = “17”, Programmer #2 = “18”, …, Pro-
grammer #24 = “40”)
15 PosID - that is Socket #
16 TimeStamp - Date/Time of SPC log entry
17 OrderNumber - Job Name and or number

■ Administrator Functions ◘ Monitoring Statistics
PSV7000 Owner’s Manual 3—17
back
If the Automotive Performance Pak is installed, an extended SPC log
file (with APP enabled) would have the following delimited fields:
18 Package - A Package File used for the job
TimeStamp
JobName
JobDescription
Device
Package
VisionPRJ
RecordID
SystemStatus
SystemMSG
FromAreaID
FromPosID
DeviceStatus
WhichCup
SNused
ToAreaID
ToPosID
DevicesInspected
InspectionPassed
InspectionQuality
DevicesInserted-
Socket
SocketYield
ProgrammerYield
ProgSysYield
The SPCOut.txt Field Descriptions

Administrative Functions ■ Administrator Functions
3—18 Data I/O • 096-0460-001B
back
*Inspection quality contains a 4 number record divided by the pipe
[|], such as 1|2|3|4.
1: 100.0-> vision pass or XXX.X->vision error code
2: dX
3: dY
4: dZ
Example:
100.0|85.0|-152.4|-1022.4
dX,dY are recorded in µm, dR is in µdegree
DevicesProcessed-
Marker
DevicesMarked
DevicesInputSys-
tem
SystemYield
SystemThrough-
putExcWait
SystemTo-
talThrough-
putIncWait
DevicesOutputSys-
tem
MachineID
ProgTime