■ Administrator Functions ◘ Monitoring Statistics PSV7000 Owner’s Manual 3—17 back If the Automotiv e P erformance P a k is installed, an extended SPC log file (with APP enabled) would have the following delimited fields…

100%1 / 186
Administrative Functions Administrator Functions
3—16 Data I/O • 096-0460-001B
back
2. Locate the section for SPC Logging. It will look like this:
[SPC Logging]
LoggingEnabled=FALSE
MaxFileSize=10485760
TempLogFile=C:\spcout.txt
3. Set the second line (LoggingEnabled) to TRUE.
4. (Optional) Edit the location of the output file at the line
“TempLogFile=...” entering the drive and path desired.
5. Save and close winAH400.ini.
Note: In the above example the SPC logging file is saved to
C:\
directory. It can, however, be saved elsewhere on the Handler Com-
puter hard drive, or on a networked drive if network connected.
The SPCOut.txt file contains semicolon-delimited fields. A partial list
follows:
The SPCOut.txt Field Descriptions
01 DevicesInputsystem - number of devices picked from Input
media
02 DevicesInspected - number of devices inspected by Vision system
03 InspectionQuality* - as percentage, compared with reference
vision
04 InspectionYield
05 DevicesInsertedSocket - number of devices inserted into socket
06 SocketYield
07 ProgrammerYield
08 ProgSysYield - Yield of all programmers together
09 DevicesProcessedMarker
10 MarkingYield
11 SystemThroughputExcWait - starts with first device placed,
excludes wait times.
12 SystemTotalThroughputIncWait - starts when Run starts,
includes wait times
13 SystemYield
14 AreaID - Programmer #1 = “17”, Programmer #2 = “18”, …, Pro-
grammer #24 = “40”)
15 PosID - that is Socket #
16 TimeStamp - Date/Time of SPC log entry
17 OrderNumber - Job Name and or number
Administrator Functions Monitoring Statistics
PSV7000 Owner’s Manual 3—17
back
If the Automotive Performance Pak is installed, an extended SPC log
file (with APP enabled) would have the following delimited fields:
18 Package - A Package File used for the job
TimeStamp
JobName
JobDescription
Device
Package
VisionPRJ
RecordID
SystemStatus
SystemMSG
FromAreaID
FromPosID
DeviceStatus
WhichCup
SNused
ToAreaID
ToPosID
DevicesInspected
InspectionPassed
InspectionQuality
DevicesInserted-
Socket
SocketYield
ProgrammerYield
ProgSysYield
The SPCOut.txt Field Descriptions
Administrative Functions Administrator Functions
3—18 Data I/O • 096-0460-001B
back
*Inspection quality contains a 4 number record divided by the pipe
[|], such as 1|2|3|4.
1: 100.0-> vision pass or XXX.X->vision error code
2: dX
3: dY
4: dZ
Example:
100.0|85.0|-152.4|-1022.4
dX,dY are recorded in µm, dR is in µdegree
DevicesProcessed-
Marker
DevicesMarked
DevicesInputSys-
tem
SystemYield
SystemThrough-
putExcWait
SystemTo-
talThrough-
putIncWait
DevicesOutputSys-
tem
MachineID