00194932-20 User Manual CAN Test Box-Error Frame Diagnostic unit_en - 第13页

1 - 13 Edition 10/2 018 SIPLACE CAN Bus 13 2.2 CAN Bus Signal Assignment Fig. 2.2 - 1 Signal assignment at the different conn ectors – CAN_INT – not in use (+5V) – Power Fail – triggers recording of operatin g data at th…

100%1 / 174
1 - 12
SIPLACE CAN Bus Edition 10/2018
12
Ordernumber Siplace CAN Bus Analysis tool: 03105007-01
Content:
The following cables will be delivered with the ordernumber of the Siplace CAN Bus analysis tool.
(1) 03050022-xx Cable 1 Power supply 5 V,
(2) 03050023-xx Cable 2 CAN Bus Test cable 1,5m,
(3) 03050024-xx Cable 3 CAN Bus Test cable 0,75m,
(4) 03050025-xx Cable 4 CAN Bus Test Cable with 10 pins e.g. Tyco-connector 0,5m.
(5) 03105577-xx USB Powersupply cable for the CAN Test Box
(6) 03043645-xx SIPLACE CAN Bus Test Box
Fig. 2.1 - 2 SIPLACE CAN Bus Analysetool 03105007-xx
Note:
The 5V power supply cable for the CAN Test Box is equipped with a 37 pin Sub-D connector. This
connector can connect on the axis board A362/A363 only. For the axis board A364 an adapter
card is necessary.
03051220-02 Adapter card for A364 or
03058164-01Universal adapter A364/A363/A362-V24
In general, the 5V power supply for the CAN Test Box, which are only necessary for the display of
the Error Frame Counter and his electronic, can realize via a standard power supply. (e.g. 5V po-
wer supply with USB hub 2.0 in our machine - 03053145-xx)
Additionally you can order the following CAN Test cable.
03159250-01 Test cable CAN Bus (Flat cable with Sub-D connector /socket and multi-pin connec-
tor)
1 - 13
Edition 10/2018 SIPLACE CAN Bus
13
2.2 CAN Bus Signal Assignment
Fig. 2.2 - 1 Signal assignment at the different connectors
CAN_INT – not in use (+5V)
Power Fail – triggers recording of operating data at the placement head (+5V)
CAN RESET – not in use (+5V) (HS50/60 use the signal for the Tape cutter and component
table)
CAN HIGH - 2,5 +/– 0,3 V recessive level (machine in idle mode)
CAN LOW - 2,5 +/– 0,3 V recessive level (machine in idle mode)
CAN GND - Can bus ground
Vcc 24V - for nozzle changers - no longer available after the above mentioned conversions
One wire - only applies to HF series, in the machine CAN bus cable
Note:
Since the X-Series S and following (SX and TX), only the communication of the CAN bus takes
place via the CAN bus cable. That CAN_H and CAN_ L signal with CAN_GND, pin assignment
see picture above.
1 - 14
SIPLACE CAN Bus Edition 10/2018
14
2.3 CAN Test Box Connections
Fig. 2.3 - 1 CAN Test Box connections
(1) Switch for setting the baud rate to 1 MBit or 500 kBit
(2) Switch for enabling an additional 120 Ohm resistance.
(3) Power LED to show the power supply state (green = power on)
5V voltage supply from the axis card or external power pack
CAN BUS PC connection PC (Sub D female connector). Only the CAN High, CAN Low and
GND signals are run to the PC (Kvaser card), preventing PC-card corruption.
CAN BUS_MA connection to the machine, COM assembly (Sub D female connector)
CAN BUS_MA connection to the machine, COM assembly (Sub D male connector)
Banana jack for CAN High measurement of recessive CAN bus level against CAN GND
Banana jack for CAN Low measurement of recessive CAN bus level against CAN GND
Banana jack for CAN GND ground CAN bus
BNC socket for CAN High
BNC socket for CAN Low
BNC socket RxD shows the combination of CAN High and CAN Low signals to a TTL level, as
read by the CAN telegram processor.
BNC socket for Error Counter from display
Error Frame Counter
Display
1
3
2