2 Overview 2.5 Serial number of module 14 Service Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 2.5 Serial number of module The serial number of the LDU-X can be found on the typeplate (1) .

2 Overview
2.4 Requirements and restrictions
Service Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 13
2.4 Requirements and restrictions
●
The LDU‑X can be used on SIPLACE X, SX and DX series machines.
●
The LDU‑X can only be set up on X tables. You can not configure the LDU-X on S tables.
●
The LDU-X can handle components up to a maximum size of 42x42 mm.
– X4i: If a WPC is used the maximum component size is 32x32 mm.
– SX1 and SX2: If the outer table position is used - depending on the head configuration -
there may be restrictions regarding the size of the components handled.
●
The LDU‑X requires station software version 604 or higher to operate on SIPLACE placement
machines.
●
The following restrictions are valid for the placement heads:
– SW 604 and 605: only C&P6, C&P12 and TwinHead
– from SW 703: no restrictions
●
The LDU‑X requires line computer software SIPLACE Pro version 5.0.1.35 and higher to op-
erate on SIPLACE placement machines.
●
The LDU‑X must be manually configured in the setup.
●
The LDU-X must not allocate the outer 6 tracks in each case (right and left).
●
You can only configure one LDU-X per table.
●
Do not set up any linear feeder modules directly next to the LDU-X.
●
Feeders with small components should not be set up directly next to the LDU-X.
●
The manual tray can not be set up on the same table as an LDU-X.
●
MTC and LDU-X units can only be set up opposite one another in single gantry machines.
●
The placement performance of the machine is limited by the dip process.
●
When dipping components, no placement data will be generated for operator information (OIS
or Ma-DaMaS).
●
A gantry can only operate with one LDU‑X (even if pickup can be performed from two place-
ment locations).
●
Only one LDU-X can be used for machines with one gantry in the placement area.
●
The LDU‑X can be operated outside the machine with the help of an SSE (Single Slot EDIF).
●
In case of SW 703 with SX there may be restrictions regarding the component size.
Hardware function status of LDU-X [03063461-xx]
Function
status
Explanation
FS1 The level sensor and refill unit can not be accommodated in this version.
FS2 In this version, the basic module is fitted 1.5 mm lower, to prevent the risk of
collisions between the level sensor and the placement head.
Software version 2.00 or higher is required to operate the level sensor.
FS3 The FS3 version has two additional sensors for detecting the dip plate and the
dip tray. This version is mandatory for the operation of the refill unit.
Software version 2.00 or higher is required for evaluation of the plate and tray
sensors, the level sensor and operation of the refill unit.

2 Overview
2.5 Serial number of module
14 Service Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
2.5 Serial number of module
The serial number of the LDU-X can be found
on the typeplate (1).

3 Installation
3.1 Station Computer
Service Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 15
3 Installation
Condition and restrictions
The LDU‑X can be used on the following machine types.
●
SIPLACE X-Series
●
SIPLACE SX-Series
●
SIPLACE CA-Series
The LDU‑X can only be set up on X tables. You can not configure the LDU-X on S tables.
To operate on SIPLACE placement machines, the LDU‑X requires:
●
Station software 604.01 with service pack 01 or higher
●
Until August 2008: SIPLACE Pro 5.0 Hotfix 01 (SIPLACE PRO Build V 5.0.1.33) and higher
●
From August 2008: SIPLACE Pro 5.2
The following placement heads can be used together with the LDU-X:
●
C&P6
●
C&P12
●
CPP
●
TwinHead
●
C&P20
The LDU‑X can be operated outside the machine with the help of an SSE (Single Slot EDIF) or a
pre-setup location.
The placement performance of the machine is limited by the DIP module.
3.1 Station Computer
The LDU-X is only supported from station software 604.01.
The user interface and the functionality of the station software for the LDU-X are largely the same
as those for the old DIP module with rotary plate.