00194550-0202_AI_Reject bin sensor_DE EN - 第20页

2 Assembly instructions: Reject bin sensor for the SIPLACE HF-series Reject bin sensor 08/2006 Edition 20 2.7 Assembly at locations with two reject bins 2 2 2 Sensors with cable

100%1 / 30
Reject bin sensor 2 Assembly instructions: Reject bin sensor for the SIPLACE HF-series
08/2006 Edition
19
2.5 General notes
2
2
2
Do NOT use magnetizable screws when fitting the sensors! 2
Only use the enclosed plastic screws (item no.: 03005925-01) for fixing the reed sensors. 2
2.6 Preparatory work
: Dock the component trolley from its location out of the machine.
: Switch the placement machine off at the main power switch.
: Move the gantry towards the PCB conveyor and remove the waste tape chute to gain easy ac-
cess to the working surface.
: If any nozzle changers are fitted, remove them at the relevant locations.
2 Assembly instructions: Reject bin sensor for the SIPLACE HF-series Reject bin sensor
08/2006 Edition
20
2.7 Assembly at locations with two reject bins
2
2
2
Sensors with cable
Reject bin sensor 2 Assembly instructions: Reject bin sensor for the SIPLACE HF-series
08/2006 Edition
21
2.8 Assembly at locations with one reject bin
2
: Fit the second sensor in the park position. Fit the scanning plate using the enclosed hexagon
socket head screws (needed to activate the sensor).
2
Sensor for scanning
the reject bin
Scanning
plate
Sensor in the