00193411-02 - 第101页

User Manual SIPLAC E HS-60 4 Setting up the placement system Software version SR.503.xx 07/2003 US Edition 4.1 Transport dimensions 101 4 Setting up the placement system 4.1 T ransport dime nsions The pla cement s ystem …

100%1 / 198
3 Technical data User Manual SIPLACE HS-60
3.10 Overview of the modules - PCB conveyor Software version SR.503.xx 07/2003 US Edition
100
User Manual SIPLACE HS-60 4 Setting up the placement system
Software version SR.503.xx 07/2003 US Edition 4.1 Transport dimensions
101
4 Setting up the placement system
4.1 Transport dimensions
The placement system mounting kit (A) on the input side can be dismantled for transportation pur-
poses. This will reduce the width of the machine from 2380 mm to 1960 mm.
4
Fig. 4.1 - 1 Dimensions of the placement system during transportation and setting up
in millimeters
4
A Mounting kit, which can be dismantled for transportation purposes
B Points for attaching the fork-lift truck (fork length: 2500 mm)
The PCB conveyor height is 830 mm ± 15 mm or 95
0mm ± 15 mm in accordance with the SMEMA
standard. The height specification for the machine will change accordingly.
4 Setting up the placement system User Manual SIPLACE HS-60
4.1 Transport dimensions Software version SR.503.xx 07/2003 US Edition
102
4.1.1 Transport configuration and transportation
The following components are not installed when the placement system is delivered from the fac-
tory:
keyboards
–monitors
fault indicator lamp and
component trolley
Æ Install the dismantled components for commissioning.
Æ Use a fork-lift truck to transport the placement system:
minimum fork length 2000 mm if the mounting kit is dismantled.
minimum fork length 2500 mm if the mounting kit is dismantled.
Æ Attach the fork-lift truck only at the indicated points.
4.1.2 Quality of the foundation
Æ Ensure that
you set up the placement system on a firm and non-vibrating foundation.
the load bearing capacity per unit area of the foundation is greater than 1000 kg/m².
4.1.3 Compressed air supply
The pressure of the compressed air supply must be between 0.65 MPa and 1.0 MPa (6.5 bar
and 10 bar).
The compressed air must conform to the specification (see Section 3.4
from page 79).
This can be achieved with
oil-free compressors, e.g. Atlas, Copco type ZR4
compressed air washer/driers
micro-filters, series X, e.g. from Zander
4.1.4 Main power supply
The power socket must be fused. The fuse ratings are:
3x32A for 3x204VAC 4
3x32A for 3x230VAC 4