00193411-02 - 第126页
5 Operator, Line engineer, Service engineer User M anual SIPLACE HS -60 5.10 Operating status indicator lamp Sof tware version SR.503.xx07/ 2003 US Edition 126 unchanged flashes ( 7,7) u nchanged No further track ava ila…

User Manual SIPLACE HS-60 5 Operator, Line engineer, Service engineer
Software version SR.503.xx 07/2003 US Edition 5.10 Operating status indicator lamp
125
– Left white fault indicator lamp L3 flashes
One or more tracks are empty on the left-hand side of the placement system. The placement
system continues to place any remaining components.
– Right white fault indicator lamp (L1) on continuously - green operating status lamp (L2) off
An error has occurred on the right-hand side of the placement system -> the placement system
has stopped.
– Left white fault indicator lamp (L1) on continuously - green operating status lamp (L2) off
An error has occurred on the left-hand side of the placement system -> the placement system
has stopped.
– Both white fault indicator lamps (L1 and L3) on continuously - green operating status lamp off
An error has occurred that affects the entire placement system -> the placement system has
stopped.
5.10.3 Programmed operating status displays
The following table shows the programmed operating status displays in the standard configuration
(version as supplied) and lists their meaning on the individual lamps of the main fault indicator.
The entries in the table next to "flashes" refer to the frequency with which the relevant lamp flashes
for a given event. The entry (1, 5), for example, can be explained as follows:
– The first number in the brackets indicates the time, expressed in 100 msec intervals, for which
the fault indicator lamp is switched on, i.e. 1 x 100 msec in the above example.
– The second number in the brackets indicates the time, expressed in 100 msec intervals, for
which the fault indicator lamp is switched off, i.e. 5 x 100 msec in the above example.
5
L1 (white)
(right lamp)
L2 (green) L3 (white)
(left lamp)
Meaning
Status display
flashes (1,10) flashes (7,7) flashes (1,10) Reference run
unchanged flashes (1,5) unchanged Waiting until axes in position
unchanged flashes (7,7) unchanged Waiting for setup data
unchanged flashes (7,7) unchanged Waiting for cluster data
unchanged flashes (7,7) unchanged Load table program
unchanged flashes (7,7) unchanged Position detection
unchanged flashes (1,10) unchanged Bad fiducial detection
unchanged flashes (7,7) unchanged Nozzle configuration test
unchanged flashes (7,7) unchanged Feeder position detection
unchanged flashes (7,7) unchanged One track is empty

5 Operator, Line engineer, Service engineer User Manual SIPLACE HS-60
5.10 Operating status indicator lamp Software version SR.503.xx07/2003 US Edition
126
unchanged flashes (7,7) unchanged No further track available
unchanged flashes (7,7) unchanged Go to refill position
unchanged flashes (7,7) unchanged Transport being initialized
unchanged flashes (7,7) unchanged Place PCB in input conveyor
flashes (1,10) flashes (7,7) unchanged Remove PCB from output conveyor
unchanged flashes (7,7) flashes (1,10) Remove PCB from output conveyor 2
flashes (1,10) flashes (7,7) flashes (1,10) Width adjustment
unchanged flashes (1,10) unchanged Transport PCB
flashes (1,10) flashes (7,7) flashes (1,10) Both output conveyors are cleared
on flashes (1,10) on Transport error
on off on Go to service position
on Placement
flashes (1,20) Waiting for processing data
Error display
on off unchanged Machine error, right
on off unchanged Track empty, right
on off unchanged Nozzle configuration, right
on off unchanged Transport error, right
on off on Fiducial error, left and right
on off on Fiducial error, left and right
unchanged off on Track empty, left
unchanged off on Nozzle configuration, left
unchanged off on Transport error, left
unchanged off on Machine error, left
Pick-up error display
unchanged unchanged flashes (1,20) First track empty, left
unchanged unchanged flashes (5,20) Further tracks empty, left
unchanged unchanged flashes (5,5) Penultimate track in use
unchanged unchanged flashes (1,2) Last track in use, right
flashes (1,20) unchanged unchanged First track empty, right
flashes (5,20) unchanged unchanged Further tracks empty, right
flashes (5,5) unchanged unchanged Penultimate track in use, right
flashes (1,2) unchanged unchanged Last track in use, right
L1 (white)
(right lamp)
L2 (green) L3 (white)
(left lamp)
Meaning

User Manual SIPLACE HS-60 6 Component handling
Software version SR.503.xx 07/2003 US Edition 6.1 Overview
127
6 Component handling
6.1 Overview
6.1.1 Feeders
The following feeders are currently available for supplying various component types to the place-
ment system:
Tape feeders 6
– 8 mm SII feeder
– 3 x 8 mm S feeder, 3 x 8 mm S feeder for 0201/0402 components
– 12 mm S feeder for capacitors based on powdered metal, model C/D
– 12 mm S feeder for capacitors based on powdered metal, model E
– 12/16, 24/32 mm S feeders
Other feeders 6
– Bulk case feeder
– Surftape feeders for 8 mm, 12 mm, and 16 mm
These feeders can be used to process the latest package forms of all components, such as bulk
cases, stick magazines, and taped components.
The most important feature of the modular component feeding system is its great flexibility. For
example, the feeding intervals can be set on the feeder. The tape feeders can handle both paper
and blister tapes. In this way, just a small selection of feeders is sufficient for inserting a wide
range of component types.
The position detection (vision) system on the feeders enables the precise component pick-up
position to be determined. The position is determined automatically whenever the feeder or com-
ponent trolley is changed.
Feeders can thus be changed quickly and easily, even by inexperienced personnel.
PLEASE NOTE 6
Detailed information on the feeders is contained in the component feeder operating instructions.6