00193411-02 - 第186页
7 Station extensions User Manual SIPLACE HS-60 7.11 Vacuum pum p Software version SR.503.xx 07/2003 US Edition 186

User Manual SIPLACE HS-60 7 Station extensions
Software version SR.503.xx 07/2003 US Edition 7.11 Vacuum pump
185
7.11 Vacuum pump
Every Collect&Place head has a separate vacuum generator that supplies the holding and place-
ment circuit with the vacuum that it needs. The vacuum generator works on the Venturi principle.
The machine's compressed air consumption is approximately 950 Nl/min, which means that the
compressed air supply must be dimensioned accordingly. If the owner does not have sufficient ca-
pacity locally, the associated investment costs would be high, so we supply a vacuum pump that
will provide the necessary vacuum.
Other advantages of using the vacuum pump are:
– It roughly halves the machine's compressed air consumption.
– It reduces the input pressure.
– The placement machine can be easily integrated into existing lines.
– The ongoing operating costs reduce according to the energy costs.
The vacuum pump is maintenance-free and 100% oil-free. They have sufficient capacity to supply
the holding circuits of the Collect&Place heads.
Compressed air consumption
of the placement machine
Supply pressure of the
placement machine
Without vacuum pump 950 Nl/min.
0.65 MPa - 1.0 MPa
(6.5 bar - 10 bar)
With vacuum pump 400 Nl/min.
0.6 MPa - 1.0 MPa
(6.0 bar - 10 bar)
7 Station extensions User Manual SIPLACE HS-60
7.11 Vacuum pump Software version SR.503.xx 07/2003 US Edition
186

User Manual SIPLACE HS-60 Index
07/2003 US Edition
187
Index
12 mm S feeder for capacitors based on powdered
metal
model C/D
133
model E
134
12/16 mm S feeder
132
12-segment Collect& Place head with DCA camera
angular accuracy
176
component specification
176
DCA camera
175
description
176
max. placement rate
176
nozzle types
176
placement accuracy
176
programable set-down force
176
range of components
176
technical data
176
travel of the Z axis
176
12-segment Collect&Place head
73, 75
angular accuracy
75
DCA camera
175
placement accuracy
75
12-segment Collect&Place head with standard com-
ponent camera
angular accuracy
91
component specifications
91
component vision module
90
description
91
max. placement rate
91
motor for "Reject" valve adjustment drive
90
nozzle types
91
overview of the modules
90
placement accuracy
91
programable set-down force
91
range of components
91
star motor
90
star with 12 sleeves
90
structure
90
technical data
91
turning station
90
Z axis drive
90
24/32 mm S feeder
135
2nd nozzle changer, location
150
3 x 8 mm S feeder
130
3x8mm S feeder for 0201/0402 CO
131
8 mm S II feeder
129
A
adapter plate
88
affected employees
69
ambient factors, permitted
79
atmospheric humidity
79
authorized accessories
24
authorized employees.
69
avoiding track errors
117
B
bulk case feeder
136
C
camera amplifier
94
capacitors based on metal-powder
41
carrying out a set-up check
110
center of gravity coordinates
81
CERAM components
173
ceramic substrate centering
167
centering slide
168
compressed air connection
168, 169
fiducial criteria
169
fiducial recommendation
169
fiducial shape
169
fiducial structure
170
general
167
maintenance
168
optical centering
169
proximity switch connecting cable
168
substrate format
169
substrate model
169
substrate thickness
169
technical data
169
changing shift
110
changing the set-up
116
changing the feeders
116
printing out the conversion instructions before
changing the set-up
116
channel for used tape disposal
146