00193411-02 - 第55页

User Manual SIPLAC E HS-60 2 Operational safety Software version SR.503.xx 07/2003 US Edition 2. 5 Safety equipment 55 2 Fig. 2.5 - 7 Safety circuits 2 Compressed air min. 0.65 MPa (6.5 bar)? No 2 Start button pressed 2 …

100%1 / 198
2 Operational safety User Manual SIPLACE HS-60
2.5 Safety equipment Software version SR.503.xx 07/2003 US Edition
54
2.5.4.2 Structure of the signalling circuit
The six signaling contacts for the covers are connected in parallel and form the "cover signal" cir-
cuit. If one or more covers are opened, the contacts close, and the 24 V signal reaches the CAN
bus and signals that one of the covers is open.
The two signaling contacts for the EMERGENCY STOP buttons are connected in parallel and form
the "emergency stop push-button signal circuit". When an EMERGENCY-STOP button is pressed,
a 24 V signal is sent to the CAN bus and signals that one of the EMERGENCY-STOP buttons has
been pressed.
The four signalling contacts for the push-button flaps are connected in parallel. They form the
"Flap signal" circuit. If one or more flaps is raised, a 24 V signal is applied to the CAN bus and
signals that one of the cover flaps is not closed.
The four signalling contacts for the CO trolleys are connected in series and form the "Component
table" signal loop. If a CO trolley is missing, a 0 V signal is sent to the CAN bus. If all trolleys are
connected, the signal is approximately 16 V.
2.5.4.3 Description of the functions of the safety circuit
The following conditions must be fulfilled before the placement system can be started or operated:
all four component trolleys must be docked in and connected.
all covers - four over the gantries, one over the PCB input belt and one over the output belt -
must be closed.
both EMERGENCY-STOP buttons must be released.
all four flaps over the push-buttons for raising and lowering the CO trolley must be closed.
the minimum operating pressure must have been reached.
the software Enable signal must have been given, thus activating the safety circuit.
The power supply must be sending 24 V to the start buttons and the protective contactor com-
bination.
If one of the start buttons is now pressed, the protective contactor combination PCC will switch
and activate the following components:
200 V link voltage for the servo amplifiers for the gantry axes
100 V link voltage for the star axes
Operating voltage for the lifting table motors
the servo unit will receive a "Servo Enable" signal for the servo amplifier.
34 V operating voltage is switched to the CO trolleys
24 V operating voltage is switched to the used tape cutters.
The machine is then ready for use.
User Manual SIPLACE HS-60 2 Operational safety
Software version SR.503.xx 07/2003 US Edition 2.5 Safety equipment
55
2
Fig. 2.5 - 7 Safety circuits
2
Compressed air
min. 0.65 MPa (6.5 bar)?
No
2
Start button pressed
2
EMERGENCY STOP
button pressed?
2
Protective cover open ?
2
Key switch
closed (position I)?
No
2
Component table
safety circuit interrupted?
Yes
No
No
Yes
Yes
No
2
Active
PCC*) Yes
Voltage
Y axis 200 V
X axis 200 V
Star axis 100 V
DP axis 30 V
Z axis 30 V
Active
PCB conveyor Yes
Lifting table Yes
PCB clamping Yes
Width adjustment Yes
Laser light barrier Yes
Used tape cutter Yes
Yes
2
Active
PCC*) No
Voltage
Y axis 0 V
X axis 0 V
Star axis 10 V
DP axis 30 V
Z axis 30 V
Active
PCB conveyor Yes
Lifting table No
PCB clamping No
Width adjustment Yes
Laser light barrier No
Used tape cutter No
2
Active
PCC*) No
Voltage
Y axis 0 V
X axis 0 V
Star axis 10 V
DP axis 30 V
Z axis 30 V
Active
PCB conveyor No
Lifting table No
PCB clamping No
Width adjustment No
Laser light barrier No
Used tape cutter No
2
*) PCC protective contactor combination
Yes
2 Operational safety User Manual SIPLACE HS-60
2.5 Safety equipment Software version SR.503.xx 07/2003 US Edition
56
2.5.5 Guard on the component table locations
DANGER 2
All locations must be equipped with feeders in order to guarantee operational reliability. If there
are not enough feeders available, a guard ("dummy feeder") must be fitted in place of the feeder.
2
Fig. 2.5 - 8 Guard on the CO trolley
2
(1) Guard for 1 location part no. 00116961-01
(2) Guard for 6 to 10 locations part no. 00116962-01
(3) Guard for 11 to 20 locations part no. 00116963-01