M20_Ope_E - 第126页

Chapter 2 Creating and Editing a Program 2-82 ④ Click the <Yes> button and exit the [Pro grammed Component & Nozzles] window. The entered number in the [Feeder Count] are reflected in the [Pickup Data]. z Incre…

100%1 / 518
Chapter 2 Creating and Editing a Program
2-81
Feeder Count
The number of feeders used for each component is displayed in the [Feeder Count] column of the
[Component] tab window.
To change the number of used feeders, enter the number in this cell.
The numbers entered in the [Feeder Count] cells are reflected in the [Pickup Data] automatically
when you exit this window.
Action:
Select one of [Component Code] steps which you want to change the number of feeders.
Enter the desired number of feeders in the [Feeder Count] cell.
(In the [Feeder Count] cell, you can enter up to as many as the number of used components
entered in the [Count /(per) Program] unless 0 or minus number.)
Click the exit button
. The following confirmation message appears.
The confirmation message appears when you exit this window.
Ex. Change the [Feeder
Count] from 1 to 2.
Chapter 2 Creating and Editing a Program
2-82
Click the <Yes> button and exit the [Programmed Component & Nozzles] window. The
entered number in the [Feeder Count] are reflected in the [Pickup Data].
z Increasing Feeder Count
The same number of increased feeders will be added as component data steps in the [Pickup Data]
window. They will be added at the end of the lines.
The added component data have the same station Nos. with the original one.
z Decreasing Feeder Count
The same number of decreased feeders will be deleted in the pickup data from the top.
Note: By executing optimization, optimum feeder station Nos. are assigned and pickup data lines are
sorted.
Sort Function
You can sort each item in the [Component] tab window by double-clicking a column title.
When you double-click a column for the first time, the column is sorted in ascending order.
Double-clicking the second time sorts the column in descending order.
One pickup data is added.
To sort the column, double click the title cell.
+: Ascending order, -: Descending order
Chapter 2 Creating and Editing a Program
2-83
Switching Simple/Detail View
You can switch window views by clicking the View (Simple/Detail)
button in the
[Programmed Components & Nozzles] window. Always the simple view appears the first.
z Simple view
z Detail view
In the detail view, the following four more columns appear.
z Delay Vaccum OK
z Coplanarity
z Vision Process Result
View (Simple/Detail)