M20_Ope_E - 第130页

Chapter 2 Creating and Editing a Program 2-86 z Finding and Arranging Image Codes Menu: Find>Find Find>Next Find>Previous Find>Sort Finding an image code containing specified text: Click Find>Find to open …

100%1 / 518
Chapter 2 Creating and Editing a Program
2-85
2-8-4-1 Customizing Tact Simulation
To obtain even accurate results or suit your specific programming, you can customize tact
simulation with various options. In the Tact Simulation dialog box, select Option>Set to open the
Set dialog box.
Nozzle tab
Tact simulation collects nozzle information from the program, allocating nozzles to the ANC and
heads so the number of nozzles are minimized. This may, however, result in increased nozzle
changes. If necessary, add some nozzles in the following steps.
When you want to customize nozzle allocation, check [Keep this setting.] check box, and perform
as follows:
Action:
Click a cell in the Nozzle column to enter nozzle name.
Right-click the mouse and select [Nozzle Select] from the popup menu. The list of nozzles
appears.
Double-click a desired nozzle name from the list.
The selected nozzle name is entered into the cell.
To delete a nozzle name, right-click the mouse with the nozzle name selected and select [Delete]
from the popup menu.
Note: Nozzle setup will change the tact time. However, changes made here won’t be applied to the
parameter setting of the system.
Feeder Type tab
Feeder types information is collected from the feeder library. You can edit [Feeder Type] and [Feed
Time] as follows:
Click the record to edit.
Right-click the mouse and select “Edit” from the provided list.
The editor window will appear. Edit [Feeder Type] using the provided combo box, [Feed
Time] by typing.
For information on the feeder drive method, see the Parts Feeders Instruction Manual. For standard
value for the record, click [Initialize] in the list. For standard value for all the records, click
[Initialize All] in the list.
Actuator tab
In the Actuator tab, settings stated below can be changed: [PCB Clamp Time], [PCB Transfer Time],
and [ANC Slide Time].
Note: For the Actuator tab settings, you can use measurements obtained via Manual>Actuator>Timing.
Simulation Cycle tab
Choose [Completion of PCB Clamp to Completion of Placement] or [Including PCB Clamp Time
and PCB Transfer Time] button. The feeder standard feed time here is applied to [Initialization] of
[Feeder Type].
Image Process Time tab
Codes in this tab are related to the image library. This tab provides the following functions:
z Image process time for each code can be changed. (unit: ms)
z New codes can be added. Right-click the mouse and select [New] from the popup menu. The
New Image Code dialog box appears. Type in a code to the entry field. Or click <Image
Library> button to select a code from the image library. After entering a code, click <OK>
button. The dialog box is closed, and the code will be added.
z Codes can be deleted. Right-click the mouse with a code selected. Select [Delete] from the
popup menu. [Data will be deleted. OK?] appears. Click <OK> button.
Chapter 2 Creating and Editing a Program
2-86
z Finding and Arranging Image Codes
Menu: Find>Find
Find>Next
Find>Previous
Find>Sort
Finding an image code containing specified text:
Click Find>Find to open the Find dialog box. Under [Character String], enter the text you want to
find. To search downward from the current (active) cell, click <Next> button. To search upward,
click <Previous> button.
Clicking Find>Next/Previous allows for finding the next or previous searched item.
Arranging the registered image codes:
Click Find>Sort to open the Sort dialog box. Click <Descend> or <Ascend> and then click <OK>
button. Clicking <Ascend> button arranges image codes in ascending order.
Example: 1, 2, 3... a, b, c...
Clicking <Descend> button arranges reversely.
Note: Changes in codes here won’t be applied to Component Library of the system.
Chapter 3 Optimization
3-1
Chapter 3
Optimization