M20_Ope_E - 第214页
Chapter 5 Libraries 5-64 * Provisional positioning windows refere nced from Component center So far, the provisional positioning windows we re always referenced from the nozzle center. Thus, sometimes that caused recogni…

Chapter 5 Libraries
5-63
* Resizing the provisional positioning windows
By modifying the second digit of [Prov. Position], you can resize the provisional positioning
windows.
[When "Prov. Position" =10~19]
[When "Prov. Position" =20~29]
[When "Prov. Position" =30~39]
[When "Prov. Position" =40~49]
[When "Prov. Position" =0~9]

Chapter 5 Libraries
5-64
* Provisional positioning windows referenced from Component center
So far, the provisional positioning windows were always referenced from the nozzle center.
Thus, sometimes that caused recognition errors because the windows were put far from the
component for the pickup offset from the component center.
Now, by inputting “1” in the digit of hundreds, the provisional positioning windows are put
referenced from the component center, not the nozzle center, no matter of the pickup offset.
Action: [Prov.Position] = 1**
Example: When [Prov.Position] is “100”, the Provisional positioning windows are put as below:

Chapter 5 Libraries
5-65
* Prov. Position values quick reference
Note: The “Prov.Position=40~49” is not below, but see the “Prov.Position=30~39” as reference.
The former shows almost half size of window than the latter.
0 10 20 30 40
1 11 21 31 41
2 12 22 32 42
3 13 23 33 43
4 14 24 34 44
5 15 25 35 45
6 16 26 36 46
7 17 27 37 47
8 18 28 38 48
9 19 29 39 49