Chapter 10 Replenishing Com ponents and Using Maintenance Menus 10-24 10-4-12 CTF Menu: Manual>CTF Allows you to check the pallet location in CTF and to manually move the pallets. Also allows you to perform initial se…

100%1 / 518
Chapter 10 Replenishing Components and Using Maintenance Menus
10-23
10-4-11 Feeder Info.
Menu: Manual>Maintenance>Feeder Info.
When manually operating a feeder on the feeder bank using Signal I/O or Actuator menu, use
this menu to specify which feeder to use. Since operation sequence of feeders may vary
depending on the feeder type, Feeder Info. setting is referred to by the system for identifying
the feeder in use and selecting appropriate operation sequence. At present, only PS-32A
requires this setting. Other feeders can operate properly without this setting. When operating
feeders in job run, the system identifies the feeders in use based on the feeder library, therefore
Feeder Setting menu need not be used.
Action:
Place the cursor in the line that corresponds to the feeder lane with a PS-32A installed.
Click the right mouse button to present the list of feeders. Select PS-32A. PS-32A is
entered to the Feeder field and 7 to the Feeder Code field.
Note: Do not change the feeder code “7” entered to the PS-32A line.
Chapter 10 Replenishing Components and Using Maintenance Menus
10-24
10-4-12 CTF
Menu: Manual>CTF
Allows you to check the pallet location in CTF and to manually move the pallets. Also allows
you to perform initial setting of CTF, especially in case of an error occurrence.
Note: To open this menu, the operator log-in level should be authorized to edit System Parameter.
Moving any Pallets or setting Transfer Speed can be also done in Pallet Library screen.
For details, see Chapter 5, Libraries > Pallet Library.
Chapter 10 Replenishing Components and Using Maintenance Menus
10-25
Move Pallet tab
Window:
Pallet:: Shows pallet on/off status of the stocker. Where the pallet is present,
the box next to each pallet number is checked.
Shuttle Pallet: When no pallet exists on the shuttle, “0” is shown. When a pallet
exists on the shuttle, its pallet number is shown.
Note: There are other functions in the [Move Pallet] tab, such as the ON/OFF operation for [Door
Lock].
Use these functions, for example, to operate the actuators for manually taking out the pallets in
cases where an error occurs in the CTF. They should not be used for normal operation.
z Adjusting CTF Initial Setting
Always be reminded to match the actual pallet setting with the display of [Pallet] and [Shuttle].
The system cannot keep track of the pallet location in the event of an error or other situation.
Under [Pallet], a checked box indicates the pallet presence at the corresponding location, an
unchecked box, pallet absence. Check or uncheck a box by clicking as necessary.
z Drawing Out a Pallet from the Stocker
Action:
Under [Pallet No.], select the pallet number with the scroll arrows.
Under [Mode], click <Out> button.
Click <Execute> button.
Execute? appears. Click <Yes> button to execute.
z Returning a Pallet to the Stocker
Action:
Under [Mode], click <In> button.
Click <Execute> button.
Execute? appears. Click <Yes> button to execute. The pallet will return to the stocker.
Note: Normally, all pallets are to be back in the stocker when a job is completed. Compare the display
in the window with the actual pallet setting to see if they match. If not, return all pallets into the
stocker.
Note: Pressing the SETUP
switch on the upper part of the CTF also returns the pallet on the elevator
to the stocker.