Chapter 10 Replenishing Com ponents and Using Maintenance Menus 10-28 10-5-1 Servo Off Menu: Manual>Maintenance>ServoOff This menu allows you to turn on/off powe r supply to each part of the machine. Window: Permit…

Chapter 10 Replenishing Components and Using Maintenance Menus
10-27
10-5 Using Maintenance Menus
The maintenance menus (Manual>Maintenance) are utilized for pre-operation arrangements
and troubleshooting. The below table summarizes the use of each maintenance menu. For
detailed information , see the following part.
However, they are mainly for Service engineer, and hardly used for standard operation.
Maintenance Menu Purpose Related Error
Servo Off Shuts off power to the servomotors. —
ANC Test Checks the ANC operation. ANC error
Illumi. Test Checks the camera lighting. Illumination error
Feeder Bank Check Checks feeder operation on the feeder
bank.
Feeder bank error
Nozzle Scan Test Checks nozzle scan function Nozzle error
Check Feeder Refer to SET MASTER in the Parts
Feeders Instruction Manual.
Pickup error
Conveyor Test Checks conveyor repeatability. Board set error
SW Check Mode Checks switch operating. Once
performed, machine system needs to
be rebooted.
—
Intelligent Feeder Checks Intelligent Feeder LED status
etc.
—
Intelligent Feeder Checks Intelligent Feeder LED status
etc.
—
Maintenance Notice Reminds you to do necessary
maintenances periodically.
—
Note: Selecting Manual>Maintenance>Servo Off makes the Power Control dialog box to appear.
Turn on/off the relevant power before starting maintenance operation. See Servo Off in the
following section.

Chapter 10 Replenishing Components and Using Maintenance Menus
10-28
10-5-1 Servo Off
Menu: Manual>Maintenance>ServoOff
This menu allows you to turn on/off power supply to each part of the machine.
Window:
Permit Turning-on...: Enables (ON) or disables (OFF) the
READY switch on the front
panel.
Servomotor: Turns on/off power to the servomotors.
Front Feeder Bank: Turns on/off power to the front feeder bank.
Rear Feeder Bank: Turns on/off power to the rear feeder bank.
Conveyor, Air cylinder...: Turns on/off power to the conveyor dc motors and the
pneumatically driven actuators. These do not include the actuators
of the heads (for pickup operation).
Action:
① Click <On> or <Off> button for each power supply.
② Click <Execute> button.
③ Click <Close> button to close the window.

Chapter 10 Replenishing Components and Using Maintenance Menus
10-29
10-5-2 ANC Test
Menu: Manual>Maintenance>ANC Test
This menu allows for testing open/close operation of ANC. It also allows for open/close
operation manually.
Testing Open/Close Operation
Action:
① Click <Execute> button. ANC starts open/close operation. The sensor response time is
measured and displayed.
② Click <Stop> button to end the check.
Note: ANC repeats open/close operation unless <Stop> button is clicked.
Window:
Open-sensor On [ms]: Operation time from when the open command is issued to when the
open sensor is turned on
Close-sensor On [ms]: Operation time from when the close command is issued to when the
close sensor is turned on
Note: The execution cycle can be specified (Min. 100ms).
Manual Open/Close Operation
Action:
① To open the slide channel, under [Slide Channel], click <Open> button.
② To close, click <Close> button.