M20_Ope_E - 第344页

Chapter 10 Replenishing Com ponents and Using Maintenance Menus 10-40 10-8 Component Handling in Machine Shutdow n If the machine stops during running, be carefu l that the component m ay drop from the head. z If STOP sw…

100%1 / 518
Chapter 10 Replenishing Components and Using Maintenance Menus
10-39
z Start the production from the steps you selected.
Action:
Open the [Run]>[Run Detail] tab.
Check on the [Start from the selected row] check box.
Click <Start Step Edit> button.
Enter the step No. to start the production.
Click the <Apply> button.
Press the
START switch to restart the production.
Chapter 10 Replenishing Components and Using Maintenance Menus
10-40
10-8 Component Handling in Machine Shutdown
If the machine stops during running, be careful that the component may drop from the head.
z If STOP
switch is pressed to suspend the machine, the machine completes the component
placement, and then stops. Therefore there is no problem.
z If
EMERGENCY STOP switch is pressed to stop the machine in an emergency, the
component remains picked up. But when
RESET switch is pressed, vacuuming at the
head is turned off. So receive the component with your hand.
z If
READY switch is still lighting, bring the head to within the reach of your hand via
Manual>Axis, and then let the component be released via Manual>Actuator>On/Off and
receive the component with your hand.
z If the front or rear cover is opened and then
RESET switch is pressed, vacuuming at the
head is turned off, and the component drops from the head.
Chapter 10 Replenishing Components and Using Maintenance Menus
10-41
10-9 Replenishing Components
10-9-1 Shortage Alarm
During a job run, when the residual component count has reached the specified setting, the
system alerts the operator to component shortage with lighting the lamp of the alarm beacon.
To enable this feature, perform the following settings:
Set [Shortage Alarm] (Program>PickupData) to the component count to give an alarm.
Set [Set Count] and [Remain Count] (Run>Run>ComponentCount>ST-F/ST-R) to the
replenished component count correctly.
When the residual component count has reached [Shortage Alarm] setting, the lamp of the
alarm beacon lights up. After that, when the remaining components have been used up, an
alarm sound (intermittent high-pitched beep) goes off, the lamp starts to blink, and the job run
is paused. You can resume operation by replenishing components and then press
START
switch.
10-9-2 Replenishing Components
Follow the below steps when component lack occurs.
Operation
Mounter status
-
Component count reaches the shortage alarm count.
Yellow alarm beacon lights up. Out of Component
Yellow alarm beacon blinks. / Alarm sounds (intermittent
high-pitched beep). /
CLEAR switch lamp lights up. /
Mounter pauses.
Press the CLEAR switch.
Alarm sound stops. CLEAR switch lamp goes out.
Yellow alarm beacon goes out.
Press the CLEAR switch.
-
Replenish components.
-
Make an entry in [Set Count] and
[Remain Count] (Run > Run >
Component Count). *
* Make an entry in [Set Count] and click <Reset Line> button
to copy it into [Remain Count]. Click <Apply Count> button
to register the entries.
Press the START switch to resume
operation.