M20_Ope_E - 第355页
Chapter 11 Parameter Setting 11-9 11-1-8 Functions Menu: System>UserParameter>Functions(1)(2)(3) Select Enable/Disable for each functi on. Use the default setting normally. Window: Production 1. Image Capture durin…

Chapter 11 Parameter Setting
11-8
11-1-7 Parameters
Menu: System>UserParameter>Parameters
Set the miscellaneous parameters. Use the default setting normally.
Window:
1. Pass Score for Vision Process Result (XY) [mm]
2. Pass Score for Vision Process Result (T) [1/1000 deg.]
3. Clearance for Automatic Conveyor width Setting [mm]
Set the play between the conveyor rails and the PCB. This setting is automatically applied
to the automatic conveyor width setting. Normally, use the default setting.
4. ZT-axis Speed after Activating <Cancel> switch [0.1%]
5. Preliminary Head Speed [0.1%, 0: Disabled]
6. Pickup Area Travel Height [mm]
7. Automatic Pickup-point correction Interval [Number of Times]
This setting is used when [APC] setting in Pickup Data is enabled.
8. Automatic Pickup-point Correction Tolerance [mm]
This setting is used when [APC] setting in Pickup Data is enabled.
9. Z-axis Speed in Return of Component [0.1%]
10. Count for Component Exhaustion (-1=Component Exhaustion at 0)
11. Pickup Tolerance [mm]
12. Feeder Support Function (Regular correction interval) [sec]
13. Feeder Support Function (Correction first time rate) [%]
14. Force-Controlled Placement Travel [mm]
15. Force-Controlled Pickup Travel [mm]

Chapter 11 Parameter Setting
11-9
11-1-8 Functions
Menu: System>UserParameter>Functions(1)(2)(3)
Select Enable/Disable for each function. Use the default setting normally.
Window:
Production
1. Image Capture during Return of Scan Camera
2. Pre-rotation
3. Return of Nozzle to ANC
4. Comp. Remain Check by Vision Process
5. Comp. Remain Check by Vacuum Pressure
6. Unclamp PCB while waiting for next process
7. Comp. Exhaustion Automatic Release
8. Definition of Nozzle Lib Negative Press Judgment
9. Scan Camera escape by comp. size check
10. Dividing Multiple pickup cycle by component size
11. Production with the limit of PCB Count
12. Manual Fiducial Auto Open
13. The First Feed After Starting Production
14. When a PCB is already on the conveyor at production

Chapter 11 Parameter Setting
11-10
15. When Z-axis does not reach Target height
16. Tray Return Timing
17. Window Auto Open for Manual Pickup Point Correction
18. Feeder Support Function
PCB Arrival Wait
19. Preliminary Pickup during PCB Arrival Wait
20. Preliminary Feeder Operation
21. Preliminary Travel to Mark during PCB Arrival Wait
Mark Process
22. Preliminary Fiducial Process (Usually select [Enable].)
23. Preliminary Bad Mark Process (Usually select [Enable].)
Optimization Postpone
24. Simple Pickup Optimization within 1-cycle (Usually check Enable.)
25. Simple Placement Optimization within 1-cycle (Usually check Enable.)
26. Automatic Nozzle Arrangement
27. Postpone Retry Step (Tray Component Only)
28. Postpone Component Exhaustion Process
29. Response when Component Exhaustion
MMI Functions
30. MMI Display Type
31. Input a Decimal point
32. Component Count Management
33. Program Restriction for editing during production
34. Common Plan
35. Remains error screen when Warnings before Run
36. Reverses Motion of Axes and Display of Rear Op.