Chapter 11 Parameter Setting 11-15 11-1-11 Travel Height Menu: System>UserParameter>Travel Height You can shift the pickup area travel heig ht upward by entering offset value. 11-1-12 Others Menu: System > User …

100%1 / 518
Chapter 11 Parameter Setting
11-14
Click the <Go> button. The following window appears.
Select the ANC No. in the Move the head to specified nozzle station box.
Click the <Execute> button.
Execute ? ANC:# message appears. Click the <OK> button to move the Teach Camera
above the specified ANC station.
Click the <Image Test> button.
When Image Test Result is NG, check to see whether there is any dirt on the mirror and nozzle
ID mark sticker, or the condition of the illumination.
Fixed Nozzle Info.
When a nozzle is fixed on a head, this nozzle is called Fixed nozzle and it can be set here.
Fixed nozzle can not be changed in ANC.
Action:
Place the fixed nozzle on a specified head.
Enter the Nozzle ID in the cell for the head.
* The number of heads differs depending on the mounter model.
Chapter 11 Parameter Setting
11-15
11-1-11 Travel Height
Menu: System>UserParameter>Travel Height
You can shift the pickup area travel height upward by entering offset value.
11-1-12 Others
Menu: System > User Parameter > Others
11-1-12-1 Performance Record
Chapter 11 Parameter Setting
11-16
Reset performance record simultaneously with the resetting of PCB count.
(Real-time data accumulation at arbitrary timing)
If this checkbox is checked, data accumulation is performed, starting from when the PCB
COUNTS counter is reset until it is reset the next time. The accumulated data will be output to
a file per accumulation block.
Note: The PCB COUNTS counter can be reset only in the following cases.
While production is not performed or the mounter is stopped by CYCLE STOP
When the PCB remaining count is 5 or larger
The counter will never be reset in any other cases.
Even if the production program is switched from one to another between PCB COUNTS
counter resets, the statistic data (per station) will contain the results of both the programs, since
it is accumulated as the same performance record.
Reset performance record when different program is executed
months before to delete Performance Record (0=Disable)
Performance record earlier than the set months will be deleted.
Output folder for real-time accumulation file (csv format) per PCB (for network only)
If this checkbox is checked, the performance record is updated at the production end of each
PCB, enabling real-time checking of the accumulated data. The designation (on the network) to
which the data is to be output must be specified. The data is output to the specified PC in CSV
format, so it can be opened using Microsoft Excel etc.
Output folder for Performance Record (Arbitrary) accumulation file (for network only)
If this checkbox is checked, the performance record (R********.Dat), that is created when Reset
Performance Record (Main Menu > Management) is selected, will be converted to a CSV file
(R********.CSV) and output to the specified folder on the PC on the network.
Operation
start
CANCEL
Operation
start
Performance record is accumulated per job.
Performance record is accumulated at
arbitrary timings.
Performance record is accumulated
in real-time
p
er PCB.
PCB 1 PCB 2 PCB n PCB n+1