M20_Ope_E - 第373页

Chapter 11 Parameter Setting 11-27 ■ Enable ID Registration If this checkbox is checked, the barcode input soft ware (InputBar) will be started autom atically when the MMI is started. → Even if the barcode input software…

100%1 / 518
Chapter 11 Parameter Setting
11-26
11-3 Intelligent Feeder (optional)
Menu: System>UserParameter>IntelligentFeeder
To enable the Intelligent Feeder, check [Enable the Intelligent Feeder Function] box and other
features in this window.
Procedures:
To enable the Intelligent Feeder, check [Enable the Intelligent Feeder Function” box and
save the User Parameter. And the Client communication software will starts up.
Æ To disable the Intelligent Feeder function, uncheck the box.
(All the feeder LED indicators will be invalid.)
Make sure the features of the Intelligent Feeder in this window.
Intelligent Function (Select one of three features.)
Not Use: Disables the Intelligent feeder function. However, the LEDs on the
intelligent feeders (out of component / component shortage / feeder error)
will remain enabled.)
Setup Verifier: Enables the feeder set mistake prevention function.
Relocatable: Enables the relocatable function (optional).
Dispense with reregistration when removed
Re-registration to the database is not necessary even if a feeder is removed from the feeder bank.
If this checkbox is not checked, registration to the database needs to be performed again if a
feeder is removed from the feeder bank.
Start production despite mislocation
If the feeder set mistake prevention function is enabled, production can still be started even if a
feeder is mis-located (feeder LED is lit in pink or flashing).
Allow to use intelligent feeder and also others
Check this checkbox when using PS and F1 feeders (non-intelligent type) with the intelligent
feeder.
Distinguish Component exhaustion and Pickup error
If this checkbox is checked, the feeder status and LED display will also be distinguished between
“out of component” and “pickup NG”.
At this moment, this checkbox must not be checked.
Chapter 11 Parameter Setting
11-27
Enable ID Registration
If this checkbox is checked, the barcode input software (InputBar) will be started automatically
when the MMI is started.
Even if the barcode input software is not started automatically, it can still be started manually
by right-clicking the client software icon on the taskbar and clicking [Execute InputBar].
Enable Server
If this checkbox is checked, the server software will be started on the mounter when the MMI is
started.
To run the server on another PC on the network, this checkbox must be unchecked.
Feeder OFF recognition time
Set the time to be expired before judgment that the feeder has been removed is made.
(Default: 2,000ms)
Server connection time
Set the time to be expired before judgment that a communication error with the server has
occurred is made. (Default: 5,000ms)
Simple check LED ON time
Set the time during which the feeder LED is to be lit when a simplified check is performed.
(Default: 2,000ms)
(Currently, the time set here is used as the time during which the feeder LED is to be lit when
the station is checked.)
If any settings are changed, click <Save>
button to save the changes.
Chapter 11 Parameter Setting
11-28
11-4 System Prameter
To enable the changes you made to the system parameters, turn off the system
once and then restart the system.
11-4-1 Machine Origin (ST)
Menu: System>SystemParameter>Parameter>MachineOrigin(ST)
Allows you to adjust coordinates of each feeder station (ST-F/R).
To perform teach entry, click in the line of the desired station and click <Teach> button to access
the Teach dialog box. When the teach entry has been done, return to the Machine Origin (ST)
dialog box and click <Save> button.
11-4-2 Head/ANC Setup
Menu: System>SystemParameter>Parameter>Head/ANC Setup
* The number of heads varies with the machine.
Head tab
To assign particular head not to be used, uncheck the head. Then click <Save> button.
ANC tab
To assign particular nozzle station not to be used, enter “0” to [Nozzle] field of the
corresponding nozzle station number (ANC No.) Then click <Save> button.