M20_Ope_E - 第379页
Chapter 12 Management Data 12-3 ■ Whole (Per Job) * Items in this window vary according to machine models and types. Run Time: Job End Time – Job Start Time (Tot al time in run mode) Job Start Time Job End Time Actual Ru…

Chapter 12 Management Data
12-2
12-1 Performance Record
This section explains how to display and output performance records.
Menu: Management > Performance Record
■Per Job
●Accumulating performance records per job
Action:
① Select Management > Performance Record.
② Select “Per Job”.
③ Select “mm” or “mil” for the unit.
④ Click <OK> button.
⑤ By referring to “Program Name”, “Start Date” and “End Date”, select the desired file.
Two or more files can be selected by clicking them while holding down the [Ctrl] key.
In addition, by clicking one file and then another while holding down the [Shift] key, all
the files between and including those two files can be selected collectively.
Note: To select two or more files, they must belong to the same production program. (It is not
possible to select files belonging to different production programs.)
⑥ Click <OK> button to display performance records. (If two or more files have been
selected, the sum of the performance records of those files will be displayed.)
⑦ If you want to output the records in text format, connect an USB memory to the USB port
of the machine and select File > Text Convert.
⑧ Select Removable Disk (G:) and click <OK> button.
⑨ A message “Convert to text data?” appears, so click <Yes>. The records will be output in
text format to the USB memory.

Chapter 12 Management Data
12-3
■Whole (Per Job)
* Items in this window vary according to machine models and types.
Run Time: Job End Time – Job Start Time (Total time in run mode)
Job Start Time
Job End Time
Actual Run Time: Rum time – Total Stop Time
Total Stop Time: Error Stop Time – Pause in Component Lack Time +
Pause Time + PCB Transfer Wait (for PCB arrival)
Error Stop Count
Pause in Component
Lack Count
Pause Count

Chapter 12 Management Data
12-4
■Total Time (Per Job)
Actual Run Time: Run Time – Total Stop Time
Pause Time: Pause time pressed by the CYCLE STOP switch
(cycle stop)
Fiducial Process Time: XY travel to mark ~ Recognition completion
Bad Mark Process Time: XY travel to mark ~ Recognition completion
MX Feeder Pallet Exchange Time: Operating time of shuttle, elevator etc.
MX Feeder Tray Replenish Time: Travel to pickup-point completion ~ Tray feed
completion (head wait time)
PCB Transfer Wait (for Pre-process): Pre-process ready ON ~ Entrance sensor ON
PCB Transfer Wait (for PCB arrival): Travel to head wait-point completion ~ PCB clamp
completion
PCB Transfer Wait (for Post-process): Production of one PCB completion (arrival at exit
buffer) ~ unloading start
PCB Transfer Wait (for PCB exit): PCB unclamp ~ Loading completed
Retry Time: Reject start ~ Re-pickup ~ Vision recognition OK
Pause in Component Lack (Feeder): Pause time due to component exhaustion
(remain count = 0)
Pause in Retry Count Limit (Feeder): Pause time due to retry over due to
pickup/vision-process error
Pause in Component Lack (Tray): Pause time due to component exhaustion
(remain count = 0)
Pause in Retry Count Limit (Tray): Pause time due to retry over due to
pickup/vision-process error
ANC Exchange Time: XY travel to ANC ~ Removal completion (Z up)
Feeder Replenish Time: Travel to pickup point completion ~ Feeder feeding
completion (head wait time)
Error Stop Time: Pause time due to errors (excluding emergency stop)
QR Code Recognition Time: PCB QR code recognition time (option)
Switching Program Time: Production-program auto-switching time with QR
code, etc. (option)
Mark Post Process Time: Recognition time for XY mark compensation.
Nozzle Scan Time: Nozzle ID recognition time
Nozzle Arrangement Time: Nozzle arrangement time for nozzle optimization