M20_Ope_E - 第379页

Chapter 12 Management Data 12-3 ■ Whole (Per Job) * Items in this window vary according to machine models and types. Run Time: Job End Time – Job Start Time (Tot al time in run mode) Job Start Time Job End Time Actual Ru…

100%1 / 518
Chapter 12 Management Data
12-2
12-1 Performance Record
This section explains how to display and output performance records.
Menu: Management > Performance Record
Per Job
Accumulating performance records per job
Action:
Select Management > Performance Record.
Select “Per Job”.
Select “mm” or “mil” for the unit.
Click <OK> button.
By referring to Program Name, Start Date and End Date, select the desired file.
Two or more files can be selected by clicking them while holding down the [Ctrl] key.
In addition, by clicking one file and then another while holding down the [Shift] key, all
the files between and including those two files can be selected collectively.
Note: To select two or more files, they must belong to the same production program. (It is not
possible to select files belonging to different production programs.)
Click <OK> button to display performance records. (If two or more files have been
selected, the sum of the performance records of those files will be displayed.)
If you want to output the records in text format, connect an USB memory to the USB port
of the machine and select File > Text Convert.
Select Removable Disk (G:) and click <OK> button.
A message “Convert to text data?” appears, so click <Yes>. The records will be output in
text format to the USB memory.
Chapter 12 Management Data
12-3
Whole (Per Job)
* Items in this window vary according to machine models and types.
Run Time: Job End Time – Job Start Time (Total time in run mode)
Job Start Time
Job End Time
Actual Run Time: Rum time – Total Stop Time
Total Stop Time: Error Stop Time – Pause in Component Lack Time +
Pause Time + PCB Transfer Wait (for PCB arrival)
Error Stop Count
Pause in Component
Lack Count
Pause Count
Chapter 12 Management Data
12-4
Total Time (Per Job)
Actual Run Time: Run Time – Total Stop Time
Pause Time: Pause time pressed by the CYCLE STOP switch
(cycle stop)
Fiducial Process Time: XY travel to mark Recognition completion
Bad Mark Process Time: XY travel to mark Recognition completion
MX Feeder Pallet Exchange Time: Operating time of shuttle, elevator etc.
MX Feeder Tray Replenish Time: Travel to pickup-point completion Tray feed
completion (head wait time)
PCB Transfer Wait (for Pre-process): Pre-process ready ON Entrance sensor ON
PCB Transfer Wait (for PCB arrival): Travel to head wait-point completion PCB clamp
completion
PCB Transfer Wait (for Post-process): Production of one PCB completion (arrival at exit
buffer) unloading start
PCB Transfer Wait (for PCB exit): PCB unclamp Loading completed
Retry Time: Reject start Re-pickup Vision recognition OK
Pause in Component Lack (Feeder): Pause time due to component exhaustion
(remain count = 0)
Pause in Retry Count Limit (Feeder): Pause time due to retry over due to
pickup/vision-process error
Pause in Component Lack (Tray): Pause time due to component exhaustion
(remain count = 0)
Pause in Retry Count Limit (Tray): Pause time due to retry over due to
pickup/vision-process error
ANC Exchange Time: XY travel to ANC Removal completion (Z up)
Feeder Replenish Time: Travel to pickup point completion Feeder feeding
completion (head wait time)
Error Stop Time: Pause time due to errors (excluding emergency stop)
QR Code Recognition Time: PCB QR code recognition time (option)
Switching Program Time: Production-program auto-switching time with QR
code, etc. (option)
Mark Post Process Time: Recognition time for XY mark compensation.
Nozzle Scan Time: Nozzle ID recognition time
Nozzle Arrangement Time: Nozzle arrangement time for nozzle optimization