M20_Ope_E - 第384页
Chapter 12 Management Data 12-8 ● Accumulating performance records by arbitrary setting Action: ① Select Management > Performance Record. ② Select “Arbitrary”. ③ Select “mm ” or “mil” for the unit. (Same as “Per Job”.…

Chapter 12 Management Data
12-7
■Arbitrary
Unlike “Per Job”, “Arbitrary” accumulates performance records at arbitrary timings.
(The same items as “Per Job” are accumulated.)
Use of this function enables easy accumulation of performance records for unit period or for
one week etc.
The following two methods of accumulating performance records at the arbitrary timings are
available.
●Resetting performance record
Management > Reset Performance Record
Performance records will be accumulated, starting from when “Reset Performance Record” is
executed until it is executed again.
●Resetting PCB count
System > User Parameter > Others
Performance records will be accumulated, starting from when the PCB count is reset until it is
reset again. To use this function, “Reset performance record simultaneously with the resetting
of PCB count” (User Parameter > Others) must be enabled.
For details, refer to “Chapter 11, Parameter Setting>Performance Record”.

Chapter 12 Management Data
12-8
●Accumulating performance records by arbitrary setting
Action:
① Select Management > Performance Record.
② Select “Arbitrary”.
③ Select “mm” or “mil” for the unit. (Same as “Per Job”.)
④ Click <OK> button. (Same as “Per Job”.)
⑤ By referring to “Program Name”, “Start Date” and “End Date”, select the desired file.
(Two or more files can be selected.) (Same as “Per Job”.)
⑥ Click <OK> button to display performance records. (If two or more files have been
selected, the sum of the performance records of those files will be displayed.) (Same as
“Per Job”.)
⑦ If you want to output the records in text format, connect an USB memory to the USB port
of the machine and select File > Text Convert.
⑧ Select Removable Disk (G:) and click <OK> button.
⑨ A message “Convert to text data?” appears, so click <Yes>. The records will be output in
text format to the USB memory.
・・・
Operation
start
CANCEL
Operation
start
・・・
Performance record is accumulated per job.
Performance record is accumulated at
arbitrary timings.
Performance record is accumulated
in real-time
p
er PCB.
PCB 1 PCB 2 PCB n PCB n+1

Chapter 12 Management Data
12-9
■Total
Used to display the total of accumulated performance records. The following two kinds of total
performance records are available: Total and User.
“Total Record” displays the total records accumulated from mounter shipment up to now.
(Cannot be reset)
“User Record” displays the total records accumulated from a reset made by the user up to now.
(Can be reset any time)
Action:
① Select Management > Performance Record.
② Select “Total”.
③ Select “mm” or “mil” for the unit.
④ Click <OK> button to display performance records.
⑤ Select Edit > Load, then select from “Total Record” or “User Record”.
⑥ If you want to output the records in text format, connect an USB memory to the USB port
of the machine and select File > Text Convert.
⑦ Select Removable Disk (G:) and click <OK> button.
⑧ A message “Convert to text data?” appears, so click <Yes>. The records will be output in
text format to the USB memory.