Chapter 14 Intelligent Feeder 14-14 14-2-7 Deleting a Component Barcode This section explains how to delete a co mponent barcode that has been registered. Action: ① Scan the "Show / Hide" barcode to display the…

Chapter 14 Intelligent Feeder
14-13
14-2-5 Re-registering to the Database
This section explains how to register the link information between component barcodes and
feeder barcodes (ID) to the server’s database. The differences from “Registering to the
Database” are that this re-registration function allows you to set any remaining component
count and to register the information to a feeder that has already been linked to a component
barcode.
Example: This function can be used in the middle of production when components in use have
been assigned to another feeder or when you want to set a remaining component count with
the consumed count deducted.
Action:
① Scan the "Show / Hide" barcode to display the ID registration window (InputBar).
② From the InputBar’s taskbar, select Mode > Remove, and then click <OK> to start
registration remove mode.
③ Scan the feeder’s barcode.
④ Scan the new component’s barcode.
⑤ Change the current remaining count displayed in the ID registration window.
⑥ Scan the "Reregister Database" barcode.
⑦ “OK” will be displayed if re-registration is completed successfully. If re-registration has
failed, read the displayed message, make necessary corrections, and then scan the
"Reregister Database" barcode again.
⑧ Scan the "Show / Hide" barcode to close the ID registration window (InputBar).
Note: Re-registration of database is only possible while production is not run.
Note: You can skip step ② when <Disable Remove Mode> button is checked in
InputBar>Option>Setup Window.
14-2-6 Canceling Database Registration
This section explains how to cancel the link information between component codes and feeder
barcodes (ID).
Action:
① Scan the "Show / Hide" barcode to display the ID registration window (InputBar).
② From the InputBar’s taskbar, select Mode > Remove to start registration remove mode.
③ Scan the feeder’s barcode.
④ Scan the "Cancel Database" barcode.
⑤ “OK” will be displayed if registration is cancelled successfully. If cancellation has failed,
read the displayed message, make necessary corrections, and then scan the "Cancel
Database" barcode again.
⑥ Scan the "Show / Hide" barcode to close the ID registration window (InputBar).
Note: You can skip step ② when <Disable Remove Mode> button is checked in
InputBar>Option>Setup Window.

Chapter 14 Intelligent Feeder
14-14
14-2-7 Deleting a Component Barcode
This section explains how to delete a component barcode that has been registered.
Action:
① Scan the "Show / Hide" barcode to display the ID registration window (InputBar).
② Scan the component’s barcode.
③ Scan the "Delete Comp. Barcode" barcode.
④ A message “Execute the Delete Command?” will appear, so click <Yes>.
⑤ “OK” will be displayed if the barcode has been deleted successfully. If deletion has failed,
read the displayed message, make necessary corrections, and then scan the "Delete Comp.
Barcode" barcode again.
⑥ Scan the "Show / Hide" barcode to close the ID registration window (InputBar).
Note: Deletion of component barcode is only possible while production is not run.
The feeder linked with the component barcode to be deleted will be deregistered. The
deregistered feeder needs to be re-registered to the database.
14-2-8 Inquire Database
This section explains how to check the component barcodes that have been linked with feeder
barcodes (ID).
Action:
① Scan the "Show / Hide" barcode to display the ID registration window (InputBar).
② Scan the feeder’s barcode.
③ Scan the "Inquire Database" barcode.
④ If the database is referred to successfully, the results will be displayed, so check them.
→If the scanned feeder barcode (ID) is not linked with a component barcode, a message
“This Feeder barcode is not registered in ID Database” will appear.
⑤ Scan the "Show / Hide" barcode to close the ID registration window (InputBar).
14-2-9 Compare Database
This section explains how to check whether the combination of a component code and a feeder
barcode (ID) is correct.
Action:
① Scan the "Show / Hide" barcode to display the ID registration window (InputBar).
② Scan the feeder’s barcode.
③ Scan the component’s barcode.
④ Scan the "Compare Database" barcode.
⑤ The verification result will be displayed, so check it.
“OK” will be displayed if the combination is correct.
→If the combination is not correct, a message “Relation between Feeder and Comp. is
improper.” will appear and the correct component barcode will be displayed.
⑥ Scan the "Show / Hide" barcode to close the ID registration window (InputBar).

Chapter 14 Intelligent Feeder
14-15
14-2-10 Checking the Station
This section explains how to find the lane (feeder) in which a component is to be set.
Action:
① Scan the "Show / Hide" barcode to display the ID registration window (InputBar).
② Scan the component’s barcode.
③ Scan the "Check Station" barcode.
④ The result will be displayed in a message window, so check it.
→If a feeder has already been set in the target lane, the LED will indicate the confirmation
status (light blue/flash) temporarily.
→For instance, a component (1005C), that is to be set in lane 34 on the front feeder bank, is
set in lane 30, a message window will appear showing: ① the lane No. in which the
component has been set by mistake, ② the correct lane No., and ③ the component name.
[Feeder position error. ST-F-30 -> ST-F-34"1005C" ID:62-20]
① ② ③
Note: The station check command can be accepted only while production is halted.
The station check function can be executed, for instance, just after <Run> button in the
production window is clicked to start production, and after production is halted to exchange
components. (In either case, production will remain halted until the [Start] button on the
mounter is pressed.)