1049 MIN,%d6, EDGE_NUM: %d1/%d8 %m T axes didn't travel to the position for nozzle Motor/ANC error. Check the error phenomenon and 1015 exchange. Head%s %d2:%d3(%d6>%d4) ANC(%d5) contact us. Check the motor error…

1014 Image data results of Debris check could not be Check the destination to save image data is proper.
960
961
%s Elevator height error for tray transfer.
%s Elevator position sensor does not respond.
Tray may have not reached transfer height properly.
Check Elevator height detect sensor and Elevator
962 %s No trays on Tray feed table
motion.
Tray may not have come out from Feed tray rack
properly.
963 %s No trays on Tray dump table. Tray may not have transferred properly.
964 %s Tray is on Shuttle unit. Tray may not have transferred properly.
965 %s Feed tray transfer error Check Feed tray at the transfer point.
966 %s Full trays in Dump tray rack. Take out empty trays from Dump tray rack. (Max.30)
967 %s Full trays in Feed tray rack. Take out trays from Feed tray rack. (Max.30)
968 %s Tray is on Tray feed table. Feed tray may not have transferred completely.
969 %s Tray is on Tray dump table. Dump tray may not have transferred properly.
970
971
%s Position error
%s Hook position error for Elevator drive
System parameter may be incorrect.
Check Hook origin detect sensor or Hook transfer
972 %s Elevator height error for Shuttle transfer.
motion.
Check Elevator height detect-sensor or Elevator
drive motion.
973
974
%s Tray is on Shuttle unit.
%s Shuttle unit is not ready at Pickup point.
Tray may not have transferred properly.
While preparation of tray feeding, error may have
occurred.
975 %s Time out for Tray feed table Up Check Tray feed table.
976 %s Time out for Tray feed table Down Check Tray feed table.
977 %s Time out for Tray dump table Up Check Tray dump table.
978 %s Time out for Tray dump table Down Check Tray dump table.
979 %s Time out for Tray stopper of Feed rack Unlock. Check Tray stopper.
980 %s Time out for Tray stopper of Feed rack Lock. Check Tray stopper.
981 %s Time out for Rack cover Lock. Check Rack cover lock.
982 %s Time out for Rack cover Unlock. Check Rack cover lock.
983 %s Time out for Feed tray push-lever On Check Feed tray push lever.
984 %s Time out for Feed tray push-lever Off. Check Feed tray push lever.
985 %s Time out for Dump tray push-lever On. Check Dump tray push lever.
986 %s Time out for Dump tray push-lever Off. Check Dump tray push lever.
987 %s Shuttle tray unlock Time out Check Shuttle tray lock.
988 %s Shuttle tray lock Time out Check Shuttle tray lock.
989 %s Hook origin Time out Check Hook.
990 %s Elevator origin Time out Check Elevator.
991 %s Hook transfer Time out Check Hook.
992 %s Elevator drive Time out Check Elevator.
993 %s Feed tray unload error Error happened while tray transfers to Tray feed
994 %s Dump tray stack error Error happened while tray transfers to Tray dump
995 %s Tray exchange interlock error. Interlock error is detected during tray exchange.
996 Undefined Vis-error Code
997 Control Message Code Error %d8
998 MT-LOG component name %m
999 Internal Error 999 Contact us.
1000 Emergency stop. %s Remove the cause of the error.
1001 Instantaneous power failure is detected. Check capacity of power source.
1002 Power failure
1003 Safety area sensor responded. Remove the obstruct in the sensing area.
Check the cover lock mechanism and the open cover
1004 Open %s was detected in the AUTO mode.
sensors.
1005 Air pressure is low.
%s Abnormal temperature of regenerative resistor is
Check the air connector on the machine rear side.
Check the temperature of the regenerative resistor
1006
detected. and cables for breaks.
Check the AUTO/MANUAL switch or others to
1007 Servo OFF signal was detected.
CFB or CTF is not connected in %s. Connect CTF or
eliminate the cause for Servo OFF.
1008
CFB by DOCKING SWITCH.
Elevator axis belt of the FTF exceeds the belt slack
Connect CTF or CFB by DOCKING SWITCH.
1009
tolerance.
Contact us.
Motor/mechanical error. Check the axis coordinates
1010 Detected the %c6%s axis end limit (+).
and contact us.
Motor/mechanical error. Check the axis coordinates
1011 Detected the %c6%s axis end limit (-).
and contact us.
1012 Request MMI Condition Check!!
An error is detected by IO operation. Check the error
1013 IO error is detected. %e
phenomenon and contact us.

1049
MIN,%d6, EDGE_NUM: %d1/%d8 %m
T axes didn't travel to the position for nozzle Motor/ANC error. Check the error phenomenon and
1015
exchange. Head%s %d2:%d3(%d6>%d4) ANC(%d5) contact us.
Check the motor error, nozzle status, or component
1016 Interlock worked while S axis was moving.
Z axis didn't reach the lowest position for nozzle
height.
Motor/ANC error. Check the error phenomenon and
1017
1018
exchange. Head%s %d2:%d3(%d6>%d4) ANC(%d5)
Nozzle was detected on the head by suction pressure
contact us.
Manual Nozzle set on head caused mismatch status
with Nozzle info. Or problem of suction pressure
inspection when nozzle was mounted to the head.
XY axes didn't travel to the position for nozzle
measuring circuit.
Motor/ANC error. Check the error phenomenon and
1019
exchange. Head%s%c1 %d2:%d3(%d6>%d4) ANC(%d5)
T axes didn't travel to the position for nozzle
contact us.
Motor/ANC error. Check the error phenomenon and
1020
exchange. Head%s %d2:%d3(%d6>%d4) ANC(%d5)
Head1 interlock worked while XY axes are moving
contact us.
Error at the head actuators/motors. Check the head
1021
(head height: %d1 < %d2).
Head2 interlock worked while XY axes are moving
height and contact us.
Error at the head actuators/motors. Check the head
1022
(head height: %d1 < %d2).
Head3 interlock worked while XY axes are moving
height and contact us.
Error at the head actuators/motors. Check the head
1023
(head height: %d1 < %d2).
Head4 interlock worked while XY axes are moving
height and contact us.
Error at the head actuators/motors. Check the head
1024
(head height: %d1 < %d2).
Head5 interlock worked while XY axes are moving
height and contact us.
Error at the head actuators/motors. Check the head
1025
(head height: %d1 < %d2).
Head6 interlock worked while XY axes are moving
height and contact us.
Error at the head actuators/motors. Check the head
1026
(head height: %d1 < %d2).
Head%c6 interlock worked while XY axes are moving
height and contact us.
Error at the head actuators/motors. Check the head
1027
(%c4 %c5: %d1 > %d2).
Head%c6 interlock worked while XY axes are moving
height and contact us.
Error at the head actuators/motors. Check the head
1028
(head height: %d1 < %d2). height and contact us.
Remove the cause of the sensor interruption and
1029 CX axis cannot operate because %s is ON.
restart.
This error is caused by effect of other errors. Check
1030 Timeout in completing immediate stop
the other error messages near around.
This error is caused by effect of other errors. Check
1031 Motion-complete stop sequence error
the other error messages near around.
This error is caused by effect of other errors. Check
1032 Timeout in completing Cancel process
The placement correction value has exceeded the
the other error messages near around.
Computing error for correction. Save Log file and
1033
limit. (X: %d1->%d2 Y: %d3->%d4) contact us.
%s motion of the Docking Station did not finish. (%c1-
1034
%c2-%c3 : %c4)
%c1 switch cannot be activated. Because CFB or CTF
1035
1036
is not connected in %s.
The component picked up by Head%s exceeds the
Pickup tolerance.(Tolerance:%d1 Offset X:%d2 Y:%d3
Connect CTF or CFB by DOCKING SWITCH.
Check the pickup coordinates.
1037
T:%d4 %c5-%d6 Step:%d7 Offset:%d8 %m )
The components picked up by Head%s and Head %c1
possibly hit each other while correcting their pickup Check the components.
angles.( %d2 < %d3 Step:%d4 Offset:%d5 %m )
%s The production cannot start because the Feed Remove the bottom tray from the Feed Rack and
1038
Tray Push Lever is in an abnormal position. resume the production.
1039 Measure nozzle height offset error Please check nozzle condition.
1040 Error occurred while the conveyor actuator worked.
Error occurred while the Automatic-conveyor-width-
Check the actuator.
1041
adjustment actuator worked.
Check the conveyor.
1042 %s is %c1. ( ID: %d2 )
Conveyor interlock error is detected while XY axes
1043
are traveling.(%s:%c3)%c4
Check the conveyor status and the related sensors.
Check the control unit and press the READY switch
1044 Control unit %s error.(%i1:%c2)
again.
1045 Discharge height error Check the board.
1046 Dispense error recheck ( %s Step:%d1 Offset:%d2 )
Interlock error is detected during %o1
1047
works.(%c2:Y:%d4 != %d5)
Measure result: %s, AVE,%d4, DEV,%d7, MAX,%d5,
1048
MIN,%d6, CENTER %c2,%d3, EDGE_NUM: %d1/%d8 %m
Measure result: %s%c2, AVE,%d4, DEV,%d7, MAX,%d5,

1083 Servo OFF signal was detected.
eliminate the cause for Servo OFF.
Error at servomotors or power source. Check the
1050 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1051 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1052 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1053 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1054 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1055 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1056 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1057 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1058 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1059 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1060 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1061 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1062 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1063 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1064 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1065 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1066 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1067 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1068 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1069 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1070 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1071 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1072 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1073 Servomotors alarm at Head%c6 %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1074 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1075 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1076 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1077 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1078 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1079 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1080 Servomotors alarm at %s (alarm code:%d1)
alarm code and contact us.
Error at servomotors or power source. Check the
1081 Servomotors alarm at %s (alarm code:%d1)
Changed to safety stop" state because %s was
alarm code and contact us.
To resume production run, close the cover and press
1082
opened." the Servo switch.
Check the AUTO/MANUAL switch or others to