M20_Ope_E - 第449页
1338 %s CFB is not set. CFB's set sensor is not responding. Set CFB in position. 1293 MX-20 Elevator Slow-down Stop (Pallet-%d1) Check conditions of MX-20. 1294 Manual opening of ANC is detected. Unconformity in noz…

1291 MX-20 Cover Open (Pallet-%d1) 0
1292 MX-20 Pallet Interlock in Stocker (Pallet-%d1) Check conditions of MX-20.
1249 Clearing of message buffer.
Message buffer is cleared because message was
paused for prescribed time.
1250
1251
MX-20 Pallet Exists on Shuttle (Pallet-%d1)
MX-20 No Pallet on Shuttle (Pallet-%d1)
Check MX-20 setting.
Check MX-20 setting.
1252
MX-20 Pallet Exists on Shuttle whereas Pallet Not
Programmed (Pallet-%d1)
Check MX-20 setting.
1253
MX-20 No Pallet on Shuttle whereas Pallet
Check MX-20 setting.
Programmed (Pallet-%d1)
1254
1255
MX-20 Pallet Exists in Stocker (Pallet-%d1)
MX-20 No Pallet in Stocker (Pallet-%d1)
Check MX-20 setting.
Check MX-20 setting.
1256
MX-20 Pallet Exists in Stocker whereas Pallet Not
Programmed (Pallet-%d1)
Check MX-20 setting.
1257
MX-20 No Pallet in Stocker whereas Pallet
Check MX-20 setting.
1258
Programmed (Pallet-%d1)
MX-20 Pallet No. Failure in Stocker (Pallet-%d1) Check MX-20 setting.
1259
MX-20 Timeout in Locking Pallet Stopper in Stocker
(Pallet-%d1)
Check conditions of MX-20.
1260
MX-20 Timeout in Unlocking Pallet Stopper in
Check conditions of MX-20.
Stocker (Pallet-%d1)
1261 MX-20 Timeout in Relay Hook Up (Pallet-%d1) Check conditions of MX-20.
1262 MX-20 Timeout in Relay Hook Down (Pallet-%d1) Check conditions of MX-20.
1263 MX-20 Timeout in Shuttle Clamp (Pallet-%d1) Check conditions of MX-20.
1264 MX-20 Timeout in Shuttle Unclamp (Pallet-%d1) Check conditions of MX-20.
1265 MX-20 Timeout in Elevator Movement (Pallet-%d1) Check conditions of MX-20.
1266
1267
MX-20 Timeout in Shuttle Movement (Pallet-%d1)
MX-20 Timeout in Relay Hook Movement (Pallet-
Check conditions of MX-20.
Check conditions of MX-20.
1268
MX-20 Timeout for Elevator Returning to Origin
(Pallet-%d1)
Check conditions of MX-20.
1269
MX-20 Timeout for Shuttle Returning to Origin
(Pallet-%d1)
Check conditions of MX-20.
1270
MX-20 Timeout for Relay Hook Returning to Origin
Check conditions of MX-20.
(Pallet-%d1)
1271 MX-20 Stocker Interlock (Pallet-%d1) Check conditions of MX-20.
1272
1273
MX-20 Relay Hook Origin Sensor On (Pallet-%d1)
MX-20 Relay Hook Origin Sensor Off (Pallet-%d1)
Check conditions of MX-20.
Check conditions of MX-20.
1274
MX-20 Relay Hook Advance End Sensor On (Pallet-
%d1)
Check conditions of MX-20.
1275
MX-20 Relay Hook Advance End Sensor Off (Pallet-
Check conditions of MX-20.
%d1)
1276
1277
MX-20 Relay Hook Down Sensor On (Pallet-%d1)
MX-20 Relay Hook Down Sensor Off (Pallet-%d1)
Check conditions of MX-20.
Check conditions of MX-20.
1278
MX-20 Pallet Clamp Off Sensor on Shuttle On
(Pallet-%d1)
Check conditions of MX-20.
1279
MX-20 Pallet Clamp Off Sensor on Shuttle Off
(Pallet-%d1)
Check conditions of MX-20.
1280
MX-20 Pallet Stopper Off Sensor in Stocker On
(Pallet-%d1)
Check conditions of MX-20.
1281
MX-20 Pallet Stopper Off Sensor in Stocker Off
(Pallet-%d1)
Check conditions of MX-20.
1282
MX-20 Failed in Assigning Elevator Moving Position
(Pallet-%d1)
Check conditions of MX-20.
1283
MX-20 Failed in Assigning Relay Hook Moving
Position (Pallet-%d1)
Check conditions of MX-20.
1284
MX-20 Failed in Assigning Shuttle Moving Position
(Pallet-%d1)
Check conditions of MX-20.
1285
MX-20 Shuttle/Conveyor-width Position Error
(Pallet-%d1)
Check conditions of MX-20.
1286
MX-20 Front Shuttle Position Sensor Not Respond
after Shuttle Movement (Pallet-%d1)
Check conditions of MX-20.
1287
MX-20 Rear Shuttle Position Sensor Not Respond
after Shuttle Movement (Pallet-%d1)
Check conditions of MX-20.
1288
MX-20 Shuttle Origin Sensor Not Respond after
Shuttle Movement (Pallet-%d1)
Check conditions of MX-20.
1289
MX-20 Relay Hook Origin Sensor Not Responds after
Relay Hook Movement (Pallet-%d1)
Check conditions of MX-20.
1290
MX-20 Relay Hook Advance End Sensor Not Respond
Check conditions of MX-20.
after Relay Hook Movement (Pallet-%d1)

1338 %s CFB is not set.
CFB's set sensor is not responding. Set CFB in
position.
1293 MX-20 Elevator Slow-down Stop (Pallet-%d1) Check conditions of MX-20.
1294
Manual opening of ANC is detected. Unconformity in
nozzle info. may occur. Job run cannot be continued.
Perform nozzle scanning.
1295
Cannot continue operation. Machine origin
unidentified.
Select <Edit&Teach> button, and perform Origin
Initialize again.
%s Returning to Origin. Origin Sensor Z-phase
1296
1297
Distance Error(Z:%d1 - O:%d2 = %d3 > %d4)
%s operation error (Pallet-%d2)
Check the origin sensor and Z-phase input.
Check pallet information or MXR.
Paper shortage of DotStation or DotStation position Refill paper of DotStation. Or check pickup station
1298
error occurred. No. of DotStation.
1299 Dot station motor alarm. Check for cleaning paper jam or motor problem.
1300 Standard device %c4%c1%s initialization error (%e) Error at control board/driver. Contact us.
1301
1302
Program error. Failed to initialize the task.
Program error
System error. Contact us.
System error. Contact us.
1303
Drive signal is not turned On. (The cover may not be
closed properly.)
System error. Contact us.
Motor alarm at the initialization of %c4%c2%s. (alarm Turn off servomotors via Maintenance>ServoOff. Ten
1304
1305
code %d1)
Option device %c4%c1%s is not initialized properly. (%e)
minutes later, turn them on.
Error at control board/driver. Contact us.
Check the setting of IC card and communication
1306 Vision system initialization error
cable. Restart the system.
1307 Air pressure at initialization is abnormal. Check the air piping and restart the system.
1308 Command sequence error Contact us.
1309 Paused for postponed retry steps. Press <Recovery> switch and then <Start> switch.
1310 Improper component feeding %s #%d1 Head%c2 Stop operation and check feeding conditions.
1311 No available feeder %s #%d1 Head%c2 Stop operation and check for presence of feeder.
1312
1313
Feeder error Head%c1
Improper component feeding %s #%d1
Out of component or no component at pickup point.
Stop running and check the feeding conditions.
1314 Job run is paused.
Set up the mounter and resume job run by pressing
<Recovery> and <Start>.
1315
Component is detected on the nozzle in comp.
Remain Check.
Check the pickup/placement and take proper
measures in the Edit & Teach mode.
%m PCB code mismatch was detected. Auto program
1316
1317
change was performed.
%m PCB code mismatch was detected.
Auto program change was performed.
PCB code mismatch was detected.
Nozzles on heads and Nozzle Information do not If the machine does not recognize nozzle IDs properly,
1318
1319
match.
No program step to execute.
contact us.
Check the program setting (skip assignment, etc.).
1320
Reached the limit of vision-process retry count (%m
%s-%d3 Head%c1 Nozzle No.%d2 Step:%d5
Check the image library data and illumination setting.
1321
Reached the limit of pickup retry count (%m %s-%d3
Head%c1 Nozzle No.%d2 Step:%d5 Offset:%d6)
Check the pickup coordinates and nozzle choice.
1322
Reached the limit of feeder retry count (%m %s-%d3
Head%c1 Nozzle No.%d2 Step:%d5 Offset:%d6)
Check the component feeding conditions.
1323
Out of component (%m %s-%d3 Head%c1 Nozzle
No.%d2 Step:%d5 Offset:%d6)
After replenishing components, update the component
count setting.
1324
Reached the limit of choke-pressure retry count
(Head%c1 Nozzle No.%d2 Step:%d5 Offset:%d6)
Check the air pressure, air filter, and nozzle data.
Check that the component feeder is mounted. Check
1325
Usable feeder is not mounted. Head%c1, Nozzle
No.%d2, Step:%d5, Offset:%d6
that the feeder is mounted on the head reachable
station.
Reached the limit of coplanarity retry count (%m %s- Check the component's image code and coplanarity
1326
1327
%d3 Head%c1 Nozzle No.%d2 Step:%d5 Offset:%d6)
Timeout in coplanarity check
data.
Check the wiring of the LIM unit.
Check the power to the LIM unit. Check the wiring of
1328 Power to the LIM unit is off.
the LIM unit.
1329 LIM unit is in the local mode. Switch the LIM unit's mode to the host mode.
1330
1331
Out of component. %s #%d1
Out of component. %s #%d1 (P%d2#-%d3 pallet)
Replenish components.
Replenish components.
1332 Components are running out. %s #%d1 rest %d2 pcs.
Components are used down to
Program>PickupData>ShortageAlarm setting.
Components are running out. %s #%d1 (P%d2#-%d3 Components are used down to
1333
pallet) rest %d4 pcs. Program>PickupData>ShortageAlarm setting.
1334 Failed to lock CFB %s. Check CFB lock mechanism.
1335 Failed to unlock CFB %s. Check CFB lock mechanism.
1336
1337
Setup ready error
Setup complete error
Check CFB lock mechanism.
Check CFB lock mechanism.

1384 ANC operation error
Check ANC shutter and missetting of nozzle. Contact
us for ANC scanning error.
1339 Communication error in image process
1340
1341
Component lack. Setup is possible %s #%d1
Pickup points of component lack are displayed.
Replenish components.
Vision process sequence error. Execute system
1342
recovery.
Check Vision processing unit or Cables for error.
1343 Failed to clamp MX-ST2. Failed to clamp MX-ST2.
1344 Failed to unclamp MX-ST2. Failed to unclamp MX-ST2.
1345 %s pallet setting error (Pallet-%d2) Check pallet information or MXR.
1346
1347
%s origin acquisition error (Pallet-%d2)
Cannot supply components from %s.
Check conditions of MXR.
Check the feeder.
The feeder is specified as unavailable feeder. %s Clear the Feeder Skip state for concerned pickup
1348
1349
#%d1
AMF measurement ends.
point(s).
1350 Setup error
This error is caused by effect of other errors. Check
the other error messages near around.
1351
Retry step postpone table is full. Execute normal
retry process.
Retry step postpone table is full. Execute normal
retry process.
MAP measurement ends. Press Start SW to convey
1352 MAP measurement ends.
out the board.
1353
1354
Axis movements are unstable.
Axis movements are unstable.
There are no usable pickup points because the
Contact us.
Contact us.
1355 machine is in the changeover state. (%m %s-%d3
Head%c1 Nozzle No.%d2 Step:%d5 Offset:%d6)
End the changeover state.
1356 Reject conveyor on %s %d1 is almost out of space.
There are no usable pickup points because Feeder
Components on Reject conveyor are almost full.
(Warning!)
1357 Skip is/are specified. (%m %s-%d3 Head%c1 Nozzle
Clear the Feeder Skip state for concerned pickup
1358
No.%d2 Step:%d5 Offset:%d6)
Controller error
point(s).
System is not operating properly. Contact us.
Check the code entry equipment for settings and
1359 PCB code entry error connections. To continue the job run, check the PCB
code and select the program.
1360 %s Motor alarm
Execute Maintenance>ServoOff. Ten minutes later,
turn on <Servo> switch.
Coordinates exceeded the setting of
1361 %s position exceeded the limit. SystemParameter>WorkRange or
SystemParameter>Axis>TravelDist.
1362 %s detected EL(+). Overrun. Take origin again.
1363 %s detected EL(-). Overrun. Take origin again.
1364 Origin of %s is not taken. Check Origin menu.
1365
1366
%s error
Error occurs at %s.
Remove error.
Remove error.
1367 %m PCB code is not defined in the Plan.
Define the PCB code in the Plan and select the
program.
Fiducial correction was not performed. Change the
1368 Fiducial error (4point)
mark location.
1369
1370
Timeout in %s operation.
ANC slide channel operates improperly.
Check cylinders, motors, and sensors.
Check cylinders and sensors.
This nozzle station is not for removing nozzles from
1371 The nozzle cannot be removed from the head.
heads.
1372 Error occurs in image processing. Check image process system and communication
1373 Device cannot be initialized. Contact us.
1374
1375
Error in opening PS-BC shutter. %s (%d1)
Error in closing PS-BC shutter. %s (%d1)
Check the shutter mechanism of the bulk feeder.
Check the shutter mechanism of the bulk feeder.
1376 Main clamp is abnormal.
Check support pin for crash. Check adjust plate for
foreign matters.
Check PCB stopper for normal operation st Manual
1377 PCB stopper is abnormal.
menu.
1378 Rear clamp is abnormal. Check rear clamp for normal operation.
1379
1380
Side clamp is abnormal.
ANC shutter is abnormal.
Check side clamp.
Check ANC shutter.
Computing error for correction. Save Log file and
1381 Fiducial error (calculation)
contact us.
1382
1383
Conveyor error
Disconnect the cable and air tube for the CFB.
Check conveyor transfer belts and motors.