M20_Ope_E - 第458页

1887 Y of reject location exceeds moveable range. Y of reject location must not exceed moveable range. 1888 Z of reject location exceeds moveable range. Z of reject location must not exceed moveable range. 1889 Theta of …

100%1 / 518
1838 X of ST(R) exceeds moveable range.
data.
1839 Y of ST(R) exceeds moveable range.
Check Y offset in pickup data and Y offset in Feeder
data.
1712 Model data is displayed. Acquired model image is displayed.
1713 Resolution is measured.
1714 Camera brightness is measured.
1715 Camera tilt is measured.
1716 T-axis center is measured.
1717 Focus is taken.
1718 VCS is requested.
1719 Version No. is acquired.
1720 Packet loop back is requested.
1721 Communication speed changes.
1722 All device & model data are deleted.
1723 Specified device data is deleted.
1724 Specified model data is deleted.
1725 Specified resolution data is deleted.
1726 All device data is sent.
1727 Device data is sent.
1728 Model data is sent.
1729 Gain/offset of camera is sent.
1730 Model data is received.
1731
1732
Detailed result of Image processing is sent.
Resolution data is backed up.
1733 Resolution data is restored.
System automatically resets vision system to cancel
1734 Reset is required.
error.
1735 Cancel is required.
1736 Head offset (S axis) is sent.
1737 Image test is completed.
1738 ADA is completed.
1800 No header file is found. Save data in Data Edit window.
1801 No board data is found. Save data in Data Edit window.
1802 No placement data is found. Save data in Data Edit window.
1803 No pickup data is found. Save data in Data Edit window.
1804 Header file is abnormal. Save data in Data Edit window.
1805 Board data file is abnormal. Save data in Data Edit window.
1806 Placement data file is abnormal. Save data in Data Edit window.
1807 Pickup data file is abnormal. Save data in Data Edit window.
1808 No component file is found. Save data in Component Library window.
1809 No feeder library is found. Save data in Feeder Library window.
1810 No packaging library is found. Save data in Packaging Library window.
1811 No nozzle ID is found. Perform automatic nozzle ID recognition.
1812 No pallet library is found. Save data in Pallet Library window.
1813 No tray library is found. Save data in Tray Library window.
1814 Component library is abnormal. Save data in Component Library window.
1815 Feeder library file is abnormal. Save data in Feeder Library window.
1816 Packaging library is abnormal. Save data in Packaging Library window.
1817 Nozzle library file is abnormal. Save data in Nozzle Library window.
1818
1819
Pallet library file is abnormal.
Tray library file is abnormal.
Save data in Pallet Library window.
Save data in Tray Library window.
1820 Image library file is abnormal. Save data in Image Library window.
Check task setting of Start block placement and End
1829 Task setting for repeat program is wrong.
block placement.
Check task setting og Multiple pickup and End
1830 Multiple pickup assignment is wrong.
multiple pickup.
The same head cannot be specified in a multiple
1831 Head specification is wrong in multiple pickup.
pickup block.
1832
Multiple pickup steps in a cycle exceeds the number
of heads.
Check the number of steps in the multiple pickup
cycle.
1833 Theta of ST(F) exceeds +/-180.00 deg. Theta must be within +/-180.00 deg.
Check X offset in pickup data and X offset in Tape
1834 X of ST(F) exceeds moveable range.
feeder data.
Check Y offset in pickup data and Y offset in Tape
1835 Y of ST(F) exceeds moveable range.
feeder data.
1836 Z of ST(F) exceeds moveable range.
Check Z offset in pickup data and Thickness in
Component data.
1837 Theta of ST(R) exceeds +/-180.00 deg. Theta must be within +/-180.00 deg.
Check X offset in pickup data and X offset in Feeder
1887 Y of reject location exceeds moveable range. Y of reject location must not exceed moveable range.
1888 Z of reject location exceeds moveable range. Z of reject location must not exceed moveable range.
1889 Theta of reject location exceeds +/-180.00 deg. Theta must be within +/-180.00 deg.
Check Z offset in pickup data and Thickness in
1840 Z of ST(R) exceeds moveable range.
Component data.
Use code of placement data in component code
1841 Component is not specified in Pickup Data.
pickup data.
1842 Component is not specified in Component data. Use component code of pickup data in Component
1843 Component name is abnormal. Code contains characters not to be used.
1844 Head number is abnormal. Enter correct head No.
1845 Fiducial group No. is wrong. Available group Nos. of fiducial are 0-249.
1846 Task setting is abnormal. Select correct item for Task in Placement data.
1847 Type setting is abnormal. Select correct item for Type in Placement data.
1848 X exceeds placement range of board. X of placement data must not exceed placeable area.
1849 Y exceeds placement range of board. Y of placement data must not exceed placeable area.
1850 Z exceeds placement range of board. Z of placement data must not exceed placeable area.
1851 X exceeds moveable range. X of placement data must not exceed moveable area.
1852 Y exceeds moveable range. Y of placement data must not exceed moveable area.
1853
1854
Z exceeds moveable range.
X exceeds board size.
Z of placement data must not exceed moveable area.
X of placement data must not exceed X of board data.
1855 Y exceeds board size. Y of placement data must not exceed X of board data.
X of head parking of board data must not exceed
1856 X of head parking exceeds moveable range
moveable range.
Y of head parking of board data must not exceed
1857 Y of head parking exceeds moveable range.
moveable range.
Z of head of parking of board data must not exceed
1858 Z of head parking exceeds moveable range.
moveable range.
1859
1860
Theta of head parking exceeds +/-180.00 deg.
Board length exceeds specified range.
Theta must be within +/-180.00 deg.
X of board data must not exceed moveable range.
1861 Board width exceeds specified range. Y of board data must not exceed moveable range.
Check X/Y/Z offset in pickup data and X/Y offset in
1862 Pickup position exceeds range.
Feeder data.
1863
1864
Feed style of pickup data is wrong.
No component code is found in Pickup Data.
Enter correct feed style for pickup data.
Enter correct component code for pickup data.
1865 ST No. exceeds range. Enter correct ST No. for pickup data.
Enter code of Feeder/Pallet data into Feeder/Pallet
1866 No feeder/pallet name is found in Pickup Data.
of pickup data.
1867
1868
No packaging/tray name is found in Pickup Data.
Pickup skip is wrong in Pickup Data.
Enter code of Packaging/Tray data into
Packaging/Tray of pickup data.
Enter correct data into Skip of Pickup data.
1869
Max. pre-processed component height exceeds range
Max. preprocessed component height must be within
0mm (0mil) to the Max. Component Height" in system
in Board Data.
parameter."
Max.component height must be within 0mm (0mil) to
1870 Max.component height exceeds range in Board Data.
the Max. Component Height" in system parameter."
Enter code of Feeder/Pallet data into Feeder/Pallet
1871
1872
No data is found in Feeder and Pallet Data.
No data is found in Packaging and Tray Data.
of pickup data.
Enter code of Packaging/Tray data into
Packaging/Tray of pickup data.
1873
The component height exceeds the Max. Component
Thickness" in Component Data ranges from 0.01mm
(0.04mil) to the "Max. Component Height" in system
Height.
parameter."
1874 Five or more continuous F mark lines are specified.
Five or more continuous F mark lines must not be
specified.
1875 No image data of F mark is found. Enter code of fiducial data into code of placement
1876 Fiducial group No. is specified prior to F. mark rows.
To use the same fiducial group, create fiducial rows
prior to placement rows.
1877 No model data for fiducial mark is found.
PackagingData>Angle must be either 0, 90, 180, or -
Acquire the model image.
PackagingData>Angle must be either 0, 90, 180, or -
1878
90 degrees. 90 degrees.
Nozzle No. registered in Component Data is not found
1879
in Nozzle information.
Perform automatic nozzle ID recognition.
1880 Nozzle pressure (Hg) exceeds range. Nozzle pressure (Hg) must be within between 1 -660.
1881 No image data is found. Enter image data into image code of Component data.
1882 Z slowdown ratio is wrong. Z slowdown ratio must be within between 1 -1000.
1883 No image data is found. Enter image code registered into Component data.
1884 Camera No. is wrong. Enter correct centering into Component data.
1885 Reject No. in Packaging Data exceeds range. Reject No. must be within 1 to 10.
1886 X of reject location exceeds moveable range.
X of reject location must not exceed moveable range.
1938 NozzleData>Directionality is set to invalid value. Enter 0, 1, or 2.
1939 ComponentData>VisionInspection is set to invalid Enter 0 or 1.
1940 0 is entered as [Pedestal Thickness].
Set [Pedestal Thickness]
(ComponentData>AdvancedSetting) to other than 0.
Component reject/reuse setting of Packaging Data is Enter correct data into Reject/Reuse of Packaging
1890
abnormal. Data.
Original X coordinate of tray data must not exceed
1891 Original X coordinate of tray data exceeds the range.
the range.
Original Y coordinate of tray data must not exceed
1892 Original Y coordinate of tray data exceeds the range.
the range.
1893
TrayData>PackageAngle must be either 0, 90, 180, or
-90 degrees.
TrayData>PackageAngle must be either 0, 90, 180, or
-90 degrees.
1894 Component height of Tray Data exceeds range. Component height of Tray Data must not exceed
Enter correct data in component reject/return of
1895 Component reject/return of Tray Data is abnormal.
Tray Data.
1896 X pitch of Tray Data exceeds range. X pitch of Tray Data must not exceed range.
1897
1898
Y pitch of Tray Data exceeds range.
Component No. of Tray Data exceeds range.
Y pitch of Tray Data must not exceed range.
X/Y components of Tray Data must be within 1 to 99.
1899 The same ST No. is used.
Link of feeder to tray is found for the same
The same ST No. must be not used.
Feeder to tray must not be linked for the same
1900
component.
Pre-alignment and multiple-view process cannot be
component.
Pre-alignment and multiple-view process must not be
1901
done for scan camera. done for scan camera. Check image code.
1902 No image data of bad mark is found.
Enter bad mark code registered into Code of
placement data.
1903 Theta of Placement Data exceeds range. Theta must be within +/-180.00 deg.
1904 Beam sensor cannot be used.
Beam sensor cannot be used for mark recognition and
teaching.
1905 Main teach camera cannot be used. No main teach camera option.
1906 Bad mark cannot be used in aux. teach camera. No main teach camera option.
1907 F mark cannot be used in aux. teach camera. No main teach camera option.
1908 Fixed camera recognition cannot be used. No fixed camera option.
1909 Scan camera recognition cannot be used. No scan camera option.
1910
1911
This head cannot be used.
No nozzle name is found.
Specified head is not installed.
Enter correct nozzle name.
1912
1913
Nozzle No. exceeds range.
Short of nozzles
Nozzle No. must be within 1 to 999.
Short of nozzles for the current program.
1914 F mark detection cannot be detected by beam sensor.
F mark detection can be detected only by main teach
camera.
1915
Bad mark detection cannot be detected by beam
sensor.
Bad mark detection can be detected only by main
teach camera.
1916
F mark detection cannot be detected by aux. teach F mark detection can be detected only by main teach
camera. camera.
1917
Bad mark detection cannot be detected by aux. teach Bad mark detection can be detected only by main
camera. teach camera.
1918 The same component name is used. The same component name must not be used.
1919 The same image code is used. The same image code must not be used.
1920 The same feeder name is used. The same feeder name must not be used.
1921 The same pallet name is used. The same pallet name must not be used.
1922 The same packaging name is used. The same packaging name must not be used.
1923 The same tray name is used. The same tray name must not be used.
1924 The same nozzle name is used. The same nozzle names must not be used.
1925 No executable program is found. No program or Skip is assigned for all the program
1926
1927
Specified feed style is not installed.
Feed style of pallet data is wrong.
Enter correct data into feed style.
Feed style must be the same with that of Pallet data.
1928 Pallet No. of pallet data exceeds range. Pallet No. range: MX-2=1, MX-40=1-20
1929 No pallet is registered in Pallet Data. Enter pallet No.
1930 Board width (Y) of Board Data exceeds the limit.
Board width (Y) 30mm(1181.1mil) or less cannot be
used.
1931
1932
No pickup data.
Specified head exceeds moveable range.
Enter pickup data.
This head cannot be used.
1933
1934
Packaging data exceeds range.
Invalid Skip setting
Enter correct Packaging data for pickup data.
Enter a number 0 or 1.
1935
Fiducial steps for compensating the execution steps
are skipped.
The program is executable. However, placement
offsets may result.
1936
Fiducial step to skip is included in sequential fiducial
Cannot perform fiducial process properly.
steps.
1937
Invalid board size is entered for automatic conveyor
width setting.
Check PCB size.