M20_Ope_E - 第459页

1938 NozzleData>Directionality is set to invalid value. Enter 0, 1, or 2. 1939 ComponentData>VisionInspection is set to invalid Enter 0 or 1. 1940 0 is entered as [Pedestal Thickness]. Set [Pedestal Thickness] (Com…

100%1 / 518
1887 Y of reject location exceeds moveable range. Y of reject location must not exceed moveable range.
1888 Z of reject location exceeds moveable range. Z of reject location must not exceed moveable range.
1889 Theta of reject location exceeds +/-180.00 deg. Theta must be within +/-180.00 deg.
Check Z offset in pickup data and Thickness in
1840 Z of ST(R) exceeds moveable range.
Component data.
Use code of placement data in component code
1841 Component is not specified in Pickup Data.
pickup data.
1842 Component is not specified in Component data. Use component code of pickup data in Component
1843 Component name is abnormal. Code contains characters not to be used.
1844 Head number is abnormal. Enter correct head No.
1845 Fiducial group No. is wrong. Available group Nos. of fiducial are 0-249.
1846 Task setting is abnormal. Select correct item for Task in Placement data.
1847 Type setting is abnormal. Select correct item for Type in Placement data.
1848 X exceeds placement range of board. X of placement data must not exceed placeable area.
1849 Y exceeds placement range of board. Y of placement data must not exceed placeable area.
1850 Z exceeds placement range of board. Z of placement data must not exceed placeable area.
1851 X exceeds moveable range. X of placement data must not exceed moveable area.
1852 Y exceeds moveable range. Y of placement data must not exceed moveable area.
1853
1854
Z exceeds moveable range.
X exceeds board size.
Z of placement data must not exceed moveable area.
X of placement data must not exceed X of board data.
1855 Y exceeds board size. Y of placement data must not exceed X of board data.
X of head parking of board data must not exceed
1856 X of head parking exceeds moveable range
moveable range.
Y of head parking of board data must not exceed
1857 Y of head parking exceeds moveable range.
moveable range.
Z of head of parking of board data must not exceed
1858 Z of head parking exceeds moveable range.
moveable range.
1859
1860
Theta of head parking exceeds +/-180.00 deg.
Board length exceeds specified range.
Theta must be within +/-180.00 deg.
X of board data must not exceed moveable range.
1861 Board width exceeds specified range. Y of board data must not exceed moveable range.
Check X/Y/Z offset in pickup data and X/Y offset in
1862 Pickup position exceeds range.
Feeder data.
1863
1864
Feed style of pickup data is wrong.
No component code is found in Pickup Data.
Enter correct feed style for pickup data.
Enter correct component code for pickup data.
1865 ST No. exceeds range. Enter correct ST No. for pickup data.
Enter code of Feeder/Pallet data into Feeder/Pallet
1866 No feeder/pallet name is found in Pickup Data.
of pickup data.
1867
1868
No packaging/tray name is found in Pickup Data.
Pickup skip is wrong in Pickup Data.
Enter code of Packaging/Tray data into
Packaging/Tray of pickup data.
Enter correct data into Skip of Pickup data.
1869
Max. pre-processed component height exceeds range
Max. preprocessed component height must be within
0mm (0mil) to the Max. Component Height" in system
in Board Data.
parameter."
Max.component height must be within 0mm (0mil) to
1870 Max.component height exceeds range in Board Data.
the Max. Component Height" in system parameter."
Enter code of Feeder/Pallet data into Feeder/Pallet
1871
1872
No data is found in Feeder and Pallet Data.
No data is found in Packaging and Tray Data.
of pickup data.
Enter code of Packaging/Tray data into
Packaging/Tray of pickup data.
1873
The component height exceeds the Max. Component
Thickness" in Component Data ranges from 0.01mm
(0.04mil) to the "Max. Component Height" in system
Height.
parameter."
1874 Five or more continuous F mark lines are specified.
Five or more continuous F mark lines must not be
specified.
1875 No image data of F mark is found. Enter code of fiducial data into code of placement
1876 Fiducial group No. is specified prior to F. mark rows.
To use the same fiducial group, create fiducial rows
prior to placement rows.
1877 No model data for fiducial mark is found.
PackagingData>Angle must be either 0, 90, 180, or -
Acquire the model image.
PackagingData>Angle must be either 0, 90, 180, or -
1878
90 degrees. 90 degrees.
Nozzle No. registered in Component Data is not found
1879
in Nozzle information.
Perform automatic nozzle ID recognition.
1880 Nozzle pressure (Hg) exceeds range. Nozzle pressure (Hg) must be within between 1 -660.
1881 No image data is found. Enter image data into image code of Component data.
1882 Z slowdown ratio is wrong. Z slowdown ratio must be within between 1 -1000.
1883 No image data is found. Enter image code registered into Component data.
1884 Camera No. is wrong. Enter correct centering into Component data.
1885 Reject No. in Packaging Data exceeds range. Reject No. must be within 1 to 10.
1886 X of reject location exceeds moveable range.
X of reject location must not exceed moveable range.
1938 NozzleData>Directionality is set to invalid value. Enter 0, 1, or 2.
1939 ComponentData>VisionInspection is set to invalid Enter 0 or 1.
1940 0 is entered as [Pedestal Thickness].
Set [Pedestal Thickness]
(ComponentData>AdvancedSetting) to other than 0.
Component reject/reuse setting of Packaging Data is Enter correct data into Reject/Reuse of Packaging
1890
abnormal. Data.
Original X coordinate of tray data must not exceed
1891 Original X coordinate of tray data exceeds the range.
the range.
Original Y coordinate of tray data must not exceed
1892 Original Y coordinate of tray data exceeds the range.
the range.
1893
TrayData>PackageAngle must be either 0, 90, 180, or
-90 degrees.
TrayData>PackageAngle must be either 0, 90, 180, or
-90 degrees.
1894 Component height of Tray Data exceeds range. Component height of Tray Data must not exceed
Enter correct data in component reject/return of
1895 Component reject/return of Tray Data is abnormal.
Tray Data.
1896 X pitch of Tray Data exceeds range. X pitch of Tray Data must not exceed range.
1897
1898
Y pitch of Tray Data exceeds range.
Component No. of Tray Data exceeds range.
Y pitch of Tray Data must not exceed range.
X/Y components of Tray Data must be within 1 to 99.
1899 The same ST No. is used.
Link of feeder to tray is found for the same
The same ST No. must be not used.
Feeder to tray must not be linked for the same
1900
component.
Pre-alignment and multiple-view process cannot be
component.
Pre-alignment and multiple-view process must not be
1901
done for scan camera. done for scan camera. Check image code.
1902 No image data of bad mark is found.
Enter bad mark code registered into Code of
placement data.
1903 Theta of Placement Data exceeds range. Theta must be within +/-180.00 deg.
1904 Beam sensor cannot be used.
Beam sensor cannot be used for mark recognition and
teaching.
1905 Main teach camera cannot be used. No main teach camera option.
1906 Bad mark cannot be used in aux. teach camera. No main teach camera option.
1907 F mark cannot be used in aux. teach camera. No main teach camera option.
1908 Fixed camera recognition cannot be used. No fixed camera option.
1909 Scan camera recognition cannot be used. No scan camera option.
1910
1911
This head cannot be used.
No nozzle name is found.
Specified head is not installed.
Enter correct nozzle name.
1912
1913
Nozzle No. exceeds range.
Short of nozzles
Nozzle No. must be within 1 to 999.
Short of nozzles for the current program.
1914 F mark detection cannot be detected by beam sensor.
F mark detection can be detected only by main teach
camera.
1915
Bad mark detection cannot be detected by beam
sensor.
Bad mark detection can be detected only by main
teach camera.
1916
F mark detection cannot be detected by aux. teach F mark detection can be detected only by main teach
camera. camera.
1917
Bad mark detection cannot be detected by aux. teach Bad mark detection can be detected only by main
camera. teach camera.
1918 The same component name is used. The same component name must not be used.
1919 The same image code is used. The same image code must not be used.
1920 The same feeder name is used. The same feeder name must not be used.
1921 The same pallet name is used. The same pallet name must not be used.
1922 The same packaging name is used. The same packaging name must not be used.
1923 The same tray name is used. The same tray name must not be used.
1924 The same nozzle name is used. The same nozzle names must not be used.
1925 No executable program is found. No program or Skip is assigned for all the program
1926
1927
Specified feed style is not installed.
Feed style of pallet data is wrong.
Enter correct data into feed style.
Feed style must be the same with that of Pallet data.
1928 Pallet No. of pallet data exceeds range. Pallet No. range: MX-2=1, MX-40=1-20
1929 No pallet is registered in Pallet Data. Enter pallet No.
1930 Board width (Y) of Board Data exceeds the limit.
Board width (Y) 30mm(1181.1mil) or less cannot be
used.
1931
1932
No pickup data.
Specified head exceeds moveable range.
Enter pickup data.
This head cannot be used.
1933
1934
Packaging data exceeds range.
Invalid Skip setting
Enter correct Packaging data for pickup data.
Enter a number 0 or 1.
1935
Fiducial steps for compensating the execution steps
are skipped.
The program is executable. However, placement
offsets may result.
1936
Fiducial step to skip is included in sequential fiducial
Cannot perform fiducial process properly.
steps.
1937
Invalid board size is entered for automatic conveyor
width setting.
Check PCB size.
1981 Z coordinate for the mark is invalid. The specified coordinates is invalid.
1982 T coordinate for the mark is invalid. The specified coordinates is invalid.
1983
There are no steps or a End Block Placement step
after the bad mark step.
Check Placement&Mark data.
1941
[Pedestal Thickness] in the component data differs Set [Pedestal Thickness] in the component data to
from the user parameter. the user parameter setting.
1942
1943
0 is entered as [Component ID] (for coplanarity
[Pallet Retract] is After pickup" when [Reject/Reuse]
Set [Component ID] to 1-255.
The component is reused but the pallet is retracted
1944
is "Reuse"."
Nozzle name error.
after placement.
Use a nozzle name from the master library.
1945
The same code is used for image code and for fiducial
Change either the image code or the mark code.
1946
mark code.
The same code is used for image code and for bad
Change either the image code or the mark code.
1947
mark code.
The same code is used for both fiducial and bad mark. Change the mark code for either one.
1948
The nozzle set on the head is different from that
specified as a fixed nozzle.
Change either the nozzle on the head or designation
of the fixed nozzle.
1949
The nozzle No. specified is not registered in the
nozzle data.
Check the nozzle No. for the component.
1950 APC is valid only for F/R banks.
Disable the APC function for other parts than F/R
banks.
1951
1952
Delay for Vacuum ON" time is out of the range."
Grip Length" is out of the range."
Enter Delay for Vacuum ON" time in the nozzle data
in the range of 0 ms to 999 ms. "
Enter Grip Length" in the nozzle data in the range of
1.5 mm to 3.5 mm(59.1 mil to 137.8 mil)."
1953 The value for [Side Pickup Offset] is out of the range.
Enter a value for [Side Pickup Offset] in the nozzle
data in the range of 0.5 mm to 2.0 mm (19.69 mil to
78.74 mil) or -0.5 mm to -2.0 mm (-19.69 mil to -
1954
ST No. for reject conveyor in the packaging data is
78.74 mil).
Change the ST No. in the packaging data.
1955
out of the range.
There are 3 fiducial steps. Fiducial process must consist of 1, 2 or 4 fiducial
1956 Fiducial numbers are different.
Give the same fiducial number for each fiducial step
group.
1957
The distance between fiducial marks is less than The distance between fiducial marks is
3mm. 3mm(118.11mil) or more.
1958 Coordinates of the fiducial is not right. The interior angle must be less than 180 degrees.
1959 The value for xa coordinate is larger than that for xb. Make the value for xb coordinate larger than that for
1960 The value for xa coordinate is larger than that for xc. Make the value for xc coordinate larger than that for
1961 The value for xd coordinate is larger than that for xb. Make the value for xb coordinate larger than that for
1962 The value for xd coordinate is larger than that for xc. Make the value for xc coordinate larger than that for
1963
1964
The value for yc coordinate is larger than that for ya.
The value for yd coordinate is larger than that for ya.
Make the value for ya coordinate larger than that for
Make the value for ya coordinate larger than that for
1965
1966
The value for yc coordinate is larger than that for yb.
The value for yd coordinate is larger than that for ya.
Make the value for yb coordinate larger than that for
Make the value for ya coordinate larger than that for
1967
Placement point is out of the valid range of 4-point Move the placement point in the valid range for 4-
fiducials. point fiducials.
1968 Assigned bad mark group is not defined.
Define the bad mark group No. for the program step
including bad mark group assignment.
1969
1970
Group Bad mark step is re-specified.
PCB bad mark is defined in the repeat steps.
Each group bad mark can be specified once.
Define the PCB bad mark outside the repeat steps.
1971 The value for bad mark group is incorrect.
Valid numbers for bad mark group are 254, 255, and 0
to 249.
1972 PCB bad mark is not defined in the first step.
Define the PCB bad mark in the first step when 254"
1973
The [Vision Inspection] is set to Not Apply" for the
component."
is specified for the bad mark group. "
Check the [Vision Inspection] in the component data.
1974
1975
Out of the valid range for compensation.
The value for Z offset for vision process" in the
component data is larger than 1mm or the component
Make it 2-point fiducial or change the mark position.
Make the value 1mm(39.37mil) or less or make it
smaller than the component thickness.
thickness."
The value for Thickness of component on nozzle" in
Make the value positive or smaller than the
1976 the component data is negative or larger than the
component thickness.
component thickness."
1977
The value for Grip Length" in the nozzle data is out Make the value in the range of 0mm to 5.5mm.(0mil to
of the range." 216.535mil.)
1978 Grip Length" is longer than the component Change the Grip Length"."
1979
1980
Task and Head do not match as the same function.
Head designation for dispensing is wrong.
Correct to match Task and Head as the same
Check the data type and head No.