2020 the specific area with height restriction at Pin setup specification. 2021 A part of the mounted component may be out of PCB area specified by PCB size. 1984 The dispense code is not registered in the dispense Regis…

100%1 / 518
1981 Z coordinate for the mark is invalid. The specified coordinates is invalid.
1982 T coordinate for the mark is invalid. The specified coordinates is invalid.
1983
There are no steps or a End Block Placement step
after the bad mark step.
Check Placement&Mark data.
1941
[Pedestal Thickness] in the component data differs Set [Pedestal Thickness] in the component data to
from the user parameter. the user parameter setting.
1942
1943
0 is entered as [Component ID] (for coplanarity
[Pallet Retract] is After pickup" when [Reject/Reuse]
Set [Component ID] to 1-255.
The component is reused but the pallet is retracted
1944
is "Reuse"."
Nozzle name error.
after placement.
Use a nozzle name from the master library.
1945
The same code is used for image code and for fiducial
Change either the image code or the mark code.
1946
mark code.
The same code is used for image code and for bad
Change either the image code or the mark code.
1947
mark code.
The same code is used for both fiducial and bad mark. Change the mark code for either one.
1948
The nozzle set on the head is different from that
specified as a fixed nozzle.
Change either the nozzle on the head or designation
of the fixed nozzle.
1949
The nozzle No. specified is not registered in the
nozzle data.
Check the nozzle No. for the component.
1950 APC is valid only for F/R banks.
Disable the APC function for other parts than F/R
banks.
1951
1952
Delay for Vacuum ON" time is out of the range."
Grip Length" is out of the range."
Enter Delay for Vacuum ON" time in the nozzle data
in the range of 0 ms to 999 ms. "
Enter Grip Length" in the nozzle data in the range of
1.5 mm to 3.5 mm(59.1 mil to 137.8 mil)."
1953 The value for [Side Pickup Offset] is out of the range.
Enter a value for [Side Pickup Offset] in the nozzle
data in the range of 0.5 mm to 2.0 mm (19.69 mil to
78.74 mil) or -0.5 mm to -2.0 mm (-19.69 mil to -
1954
ST No. for reject conveyor in the packaging data is
78.74 mil).
Change the ST No. in the packaging data.
1955
out of the range.
There are 3 fiducial steps. Fiducial process must consist of 1, 2 or 4 fiducial
1956 Fiducial numbers are different.
Give the same fiducial number for each fiducial step
group.
1957
The distance between fiducial marks is less than The distance between fiducial marks is
3mm. 3mm(118.11mil) or more.
1958 Coordinates of the fiducial is not right. The interior angle must be less than 180 degrees.
1959 The value for xa coordinate is larger than that for xb. Make the value for xb coordinate larger than that for
1960 The value for xa coordinate is larger than that for xc. Make the value for xc coordinate larger than that for
1961 The value for xd coordinate is larger than that for xb. Make the value for xb coordinate larger than that for
1962 The value for xd coordinate is larger than that for xc. Make the value for xc coordinate larger than that for
1963
1964
The value for yc coordinate is larger than that for ya.
The value for yd coordinate is larger than that for ya.
Make the value for ya coordinate larger than that for
Make the value for ya coordinate larger than that for
1965
1966
The value for yc coordinate is larger than that for yb.
The value for yd coordinate is larger than that for ya.
Make the value for yb coordinate larger than that for
Make the value for ya coordinate larger than that for
1967
Placement point is out of the valid range of 4-point Move the placement point in the valid range for 4-
fiducials. point fiducials.
1968 Assigned bad mark group is not defined.
Define the bad mark group No. for the program step
including bad mark group assignment.
1969
1970
Group Bad mark step is re-specified.
PCB bad mark is defined in the repeat steps.
Each group bad mark can be specified once.
Define the PCB bad mark outside the repeat steps.
1971 The value for bad mark group is incorrect.
Valid numbers for bad mark group are 254, 255, and 0
to 249.
1972 PCB bad mark is not defined in the first step.
Define the PCB bad mark in the first step when 254"
1973
The [Vision Inspection] is set to Not Apply" for the
component."
is specified for the bad mark group. "
Check the [Vision Inspection] in the component data.
1974
1975
Out of the valid range for compensation.
The value for Z offset for vision process" in the
component data is larger than 1mm or the component
Make it 2-point fiducial or change the mark position.
Make the value 1mm(39.37mil) or less or make it
smaller than the component thickness.
thickness."
The value for Thickness of component on nozzle" in
Make the value positive or smaller than the
1976 the component data is negative or larger than the
component thickness.
component thickness."
1977
The value for Grip Length" in the nozzle data is out Make the value in the range of 0mm to 5.5mm.(0mil to
of the range." 216.535mil.)
1978 Grip Length" is longer than the component Change the Grip Length"."
1979
1980
Task and Head do not match as the same function.
Head designation for dispensing is wrong.
Correct to match Task and Head as the same
Check the data type and head No.
2020 the specific area with height restriction at Pin setup
specification.
2021
A part of the mounted component may be out of PCB
area specified by PCB size.
1984
The dispense code is not registered in the dispense
Register dispense codes to be used.
data.
1985
1986
Coordinates for the dispense check step are invalid.
The offset value in the dispense data exceeds
The operation to specify coordinates here is invalid.
Correct the offset value in Dispense Data to be within
1987
DotStation area.
The image code in the dispense data is not registered.
DotStation area.
Register image codes to be used.
1988 Board size is not specified.
Data check for placement coordinates cannot be
performed properly.
1989 Distance for line dispense is not proper.
The value for the distance between the start and end
of discharge is negative.
1990 No line dispense option.
Line dispense cannot be assigned because the
optional line dispensing function is not included in this
1991 Line dispense designation is not proper.
There is no Start Line assignment before the End
Line assignment.
1992
1993
Feed style in the pallet data is not correct.
The syringe code is not registered in the syringe data.
Select the correct unit for the feed style.
Register syringe codes to be used.
1994 T coordinates for Repeat Offset steps will be invalid.
To make T coordinates for Repeat Offset steps valid,
perform block data conversion.
1995 The nozzle may interfere with placed components.
The problem may be solved if you place the thick
1996
This machine cannot use edge registration. It uses
component last.
Set Pin/Clamp for registration in Board data.
1997
clamp registration.
Thickness" is not specified in the Component Data." Input Thickness value in Component Data.
1998
The nozzle may interfere with pre-processed
components.
Check the Max Pre-processed Component Height in
Board Data.
1999
Repeat placement cannot be performed when PCB
Perform Block Data Conversion"."
2000
select bad mark" is used."
Optimization of nozzle arrangement was not Optimization of nozzle arrangement was not
2001
performed because of ANC shortage.
Reject tray No. is not specified in Reject Location No.
performed because of several factors.
Set 1" for Reject tray (F)
2002
Reuse" is selected although the feed style is "ST-F"
or "ST-R"."
Check that the setting of Reject/Reuse" is proper for
the target component code."
2003
Reject Location No. for reject conveyors must be 1 to
10.
Specify a number from 1 to 10 for Reject Location
No.
2004 Station No. for reject conveyor is not specified.
Specify the Station No. where Reject conveyor is set
in Pick data.
2005
2006
Reject Location No. for specified positions must be 3
to 10.
Reject Conveyor is selected although the feed style is
Specify a number from 3 to 10 for Reject Location
No. in Pick data.
Check that the setting of Reject/Reuse" is proper for
MX"." the target component code."
Y coordinate from ST origin should be in range of
2007 Y coordinate for reject tray is invalid. +56mm - +86mm for front, and -56mm - -86mm for
rear.
2008
Coordinates for reject location is either in ANC/Fixed
Camera area or in MX movable area.
Check the setting of Reject Location in User
Parameter whether the specified coordinates are
2009
The pickup point specified by Pickup Priority does not
exist.
Check the existence of the pickup point specified by
Pickup Priority.
2010
Pickup Area Travel Height + Offset value exceeds Set the Pickup Area Travel Height" to be below the
Normal Travel Height. "Normal Travel height". "
2011
This component code is registered in Pickup Data, but
Check the Placement&Mark data whether the skip
2012
it is skipped or not used in Placement & Mark Data.
setting is proper.
Reject Location No. in Tray Data exceeds range. Reject Location No. must be within 1 to 10.
2013
2014
X offset of pickup point is out of range. Check that the pickup coordinate is correct.
Y offset of pickup point is out of range. Check that the pickup coordinate is correct.
2015
The Repeat Offset data is not proper so that
placement points may be overlapped.
2016
Placement area of the component may be overlapped
with others.
2017
Flange part of nozzle may collapse with any of
mounted components on PCB.
Change the mounting order for the taller components
to be the last.
2018
2019
The mount point for the component is out of possible
placement area.
The mount point for the component is out of possible
placement area at Pin setup specification.
The component height exceeds the limit(2.0mm) in
2053 Too many fiducial processes.
(repeat steps included).
2054 The dispense point is out of the possible dispense
2055
The dispense point is out of the possible dispense
area at Pin setup specification.
2022
Prerotation function is not available because the
nozzle has restriction for rotation.
The nozzle is set to Fixed" or "Fixed(reversible)" for
Directionality
2023
The specified mark position is out of possible
recognition area.
2024
The specified mark position is out of possible
recognition area at Pin setup specification.
2025
2026
A part of the mark may be out of PCB area specified
by PCB size.
The component code name in the Placement data If there are any component codes containing any
2027
contains any space"key entries."
Component pickup surface height is set smaller than
Grip length.
space" key entries
Component pickup surface height should be set bigger
than Grip length. (Set 0 for the setting when pickup
Pre-rotation function cannot be performed when
height is same as component thickness.)
Take one of the following ways; specify Single
2028
2029
different mount angle is specified for each of
oriented-nozzles in the same cycle.
Pre-rotation cannot be performed for oriented-nozzle
Pickup" for Task
Take one of the following ways; specify Single
with other nozzles' rotation process in the same
The pre-rotation processed component may rotate
Pickup" for Task
To keep pre-rotated status, specify Single Pickup"
2030 after vision recognition because of other Heads'
rotating action in the same cycle.
for Task
2031
Feeder cannot set on the location because of
interference with next feeder.
Change ST No. to make more space with next feeder.
2032
The component size may be too small for the
specified camera to recognize.
Change Centering" setting to use another camera."
2033
The component size may be too larger for the
Change Centering" setting to use another camera
2034
specified camera to recognize.
The component height exceeds the limit for the
Change Centering" setting to use another camera."
2035
specified camera.
There is no model data for pattern matching. Acquire the model data.
2036
Some pickup records not used for the program have Be sure that this pickup record is not used during
2037
the same ST No. specified with others. production.
The components picked by both ends of head are too To avoid collision with scan camera, the multiple
large to perform multiple pickup in a same cycle. pickup will be divided in different pickup cycle.
2038
2039
Component is too large and may hit the scan camera. Select a fixed camera or change the head No.
The specified coordinates for dispensing are
2040
overlapping with others.
Coplanarity Check data is not registered. Please check Coplanarity Check data in Image data.
2041
2042
The number of Coplanarity check data to be used for
production is over the maximum, 99 records.
The Coplanarity check is not available even though it
Check the Coplanarity Check box in User Parameter.
is set to Use" in Component Data."
Spaces among the components that are captured
The same components that are measured at the same
2043
sequentially at Coplanarity Check are incorrect.
angle will be captured sequentially. Pick up the
components at the specified pitch intervals.
2044
Coplanarity check for this component cannot be
performed.
Choose Not Use" to disable "Coplanarity" fucntion
for this component."
2045
2046
The selected head unit is not equipped with
Coplanarity Checker.
The specified parameter for Transfer time after PCB
Select a correct head unit for Coplanarity Check.
It should be 101ms or more.
2047
passed the arrival sensor" is too much small."
The specified parameter for Delay for PCB Simul.
It should be bigger than the parameter of Transfer
time after PCB passed the arrival sensor" for 50ms
2048
Transfer" is too much small. "
When using the Relocatable function, it may be
impossible to start production if any pickup data are
or more."
Skip setting must be done in Placement data instead
set to NotAvailable"."
The component may collide with the other component
of pickup data.
2049 picked up by next head in a same pickup cycle
Divide the pickup cycle in different cycles or use
because of its large size.
other head to pick up in order to avoid the collision.
2050
Board Size has not been set yet, and data check for
mounting points cannot be performed.
Input Board Size correctly.
2051 There are any Placement steps skipped. Some components will not be placed. Check data
2052 There are any Pickup data skipped. Some components will not be placed. Check data
The number of fiducial processes must be 300 or less