2094 Entered value in Pallet Data>Speed is too slow. Enter 100(10%) or higher speed. 2095 Component outer size exceeds the capture limit of Head 1,4,5,8. Possible capture size of Head 1,4,5,8 is width 11mm or less. Ch…

100%1 / 518
2053 Too many fiducial processes.
(repeat steps included).
2054 The dispense point is out of the possible dispense
2055
The dispense point is out of the possible dispense
area at Pin setup specification.
2022
Prerotation function is not available because the
nozzle has restriction for rotation.
The nozzle is set to Fixed" or "Fixed(reversible)" for
Directionality
2023
The specified mark position is out of possible
recognition area.
2024
The specified mark position is out of possible
recognition area at Pin setup specification.
2025
2026
A part of the mark may be out of PCB area specified
by PCB size.
The component code name in the Placement data If there are any component codes containing any
2027
contains any space"key entries."
Component pickup surface height is set smaller than
Grip length.
space" key entries
Component pickup surface height should be set bigger
than Grip length. (Set 0 for the setting when pickup
Pre-rotation function cannot be performed when
height is same as component thickness.)
Take one of the following ways; specify Single
2028
2029
different mount angle is specified for each of
oriented-nozzles in the same cycle.
Pre-rotation cannot be performed for oriented-nozzle
Pickup" for Task
Take one of the following ways; specify Single
with other nozzles' rotation process in the same
The pre-rotation processed component may rotate
Pickup" for Task
To keep pre-rotated status, specify Single Pickup"
2030 after vision recognition because of other Heads'
rotating action in the same cycle.
for Task
2031
Feeder cannot set on the location because of
interference with next feeder.
Change ST No. to make more space with next feeder.
2032
The component size may be too small for the
specified camera to recognize.
Change Centering" setting to use another camera."
2033
The component size may be too larger for the
Change Centering" setting to use another camera
2034
specified camera to recognize.
The component height exceeds the limit for the
Change Centering" setting to use another camera."
2035
specified camera.
There is no model data for pattern matching. Acquire the model data.
2036
Some pickup records not used for the program have Be sure that this pickup record is not used during
2037
the same ST No. specified with others. production.
The components picked by both ends of head are too To avoid collision with scan camera, the multiple
large to perform multiple pickup in a same cycle. pickup will be divided in different pickup cycle.
2038
2039
Component is too large and may hit the scan camera. Select a fixed camera or change the head No.
The specified coordinates for dispensing are
2040
overlapping with others.
Coplanarity Check data is not registered. Please check Coplanarity Check data in Image data.
2041
2042
The number of Coplanarity check data to be used for
production is over the maximum, 99 records.
The Coplanarity check is not available even though it
Check the Coplanarity Check box in User Parameter.
is set to Use" in Component Data."
Spaces among the components that are captured
The same components that are measured at the same
2043
sequentially at Coplanarity Check are incorrect.
angle will be captured sequentially. Pick up the
components at the specified pitch intervals.
2044
Coplanarity check for this component cannot be
performed.
Choose Not Use" to disable "Coplanarity" fucntion
for this component."
2045
2046
The selected head unit is not equipped with
Coplanarity Checker.
The specified parameter for Transfer time after PCB
Select a correct head unit for Coplanarity Check.
It should be 101ms or more.
2047
passed the arrival sensor" is too much small."
The specified parameter for Delay for PCB Simul.
It should be bigger than the parameter of Transfer
time after PCB passed the arrival sensor" for 50ms
2048
Transfer" is too much small. "
When using the Relocatable function, it may be
impossible to start production if any pickup data are
or more."
Skip setting must be done in Placement data instead
set to NotAvailable"."
The component may collide with the other component
of pickup data.
2049 picked up by next head in a same pickup cycle
Divide the pickup cycle in different cycles or use
because of its large size.
other head to pick up in order to avoid the collision.
2050
Board Size has not been set yet, and data check for
mounting points cannot be performed.
Input Board Size correctly.
2051 There are any Placement steps skipped. Some components will not be placed. Check data
2052 There are any Pickup data skipped. Some components will not be placed. Check data
The number of fiducial processes must be 300 or less
2094 Entered value in Pallet Data>Speed is too slow. Enter 100(10%) or higher speed.
2095
Component outer size exceeds the capture limit of
Head 1,4,5,8.
Possible capture size of Head 1,4,5,8 is width 11mm
or less. Change the head No.
2096 Set position of the reject conveyor is not proper. Set the reject conveyor at a feeder placeable station.
2056
The Repeat Offset data is not proper so that
dispense points may be overlapped.
2057
The setting position of PS-MS3 exceeds allowable
range.
Do not set the PS-MS3 on the 2 feeder stations from
both ends of the feeder bank.
2058
Pre-rotation function is disabled because coplanarity
check function is specified.
The tip of the nozzle will move down lower than the Check Z of placement data, thickness and Z of board
2059
board surface when it mounts a component. origin of board data.
Specify the correct Head unit corresponding to the
2060
2061
Different Head unit is specified. Tray unit or specify the correct Tray unit
corresponding to the Head unit.
This unit cannot handle the inspection head. Specify the unit that has an inspection function.
2062 A different head unit is used for Multiple Pickup.
The components having unequal Illumination and
Specify Multiple Pickup with heads in a same unit.
2063 Gain/Offset values within one cycle will be Still-
captured.
2064 A shared Fiducial Mark step has not been created.
Uncheck the Share the Fiducial Mark Information"
check box
2065
Specified line as a shared Fiducial Mark step is not
correct.
Create the shared Fiducial Mark step at the top line
in Placement&Mark Data.
Component outer size exceeds the capture limit of Possible capture size of Head 1,4,5,8 is width 8mm or
2066
Head 1,4,5,8. less. Change the head No.
Input proper PCB length or decrease the number of
2067 PCB length is too long.
Placement stages.
2068 PCB length exceeds the limit.
Less than the possible number of placement stages is
2069
selected.
You can increase the number of Placement stages.
2070 It exceeds the placement range of Head unit B.
Head unit B cannot use Shared fiducial marks on the
Change a head or select Head unit A.
2071
2072
machine mounting two Placement stages.
Beam camera recognition cannot be used. Change Centering" setting to use another camera."
Pickup No. is not correct. (The feeder may not be
2073
attached in the position.)
The component may interfere with the next nozzle
Check no obstacles at both sides of the feeder.
Divide the pickup cycle in different cycles or use
2074
because its size is too large. other head to pick up in order to avoid the collision.
2075 Multiple-view process assignment is not proper. Select a proper multiple-view process.
Shared Fiducial/Bad mark is invalid when Mount
2076
2077
Stage Count is 1.
No image code for Image capture is found.
Uncheck the Shared Mark check box.
Register an image code.
2078
2079
No image code for Image matching is found. Register an image code.
Placement steps exist prior to Image capture steps. Perform Image capture before starting placement.
2080
Placement other than BGA is found after Image
matching process.
Insert BGA placement steps right after Image
matching steps.
The number of Image capture and that of Image
2081
matching are not the same.
2082
The coordinates of Image capture and that of Image
matching do not match.
2083
2084
No fiducial mark process of this unit is found.
This Fiducial Group No. is not used.
Add fiducial mark steps.
2085
Board width (Y) of Board Data exceeds the limit
because of RTS-1.
2086
More than the number of heads is assigned in Pickup
Order.
Within the number of heads must be assigned in
Pickup Order.
Pickup Order is invalid because Pickup Priority is not
2087
specified.
2088
The same coordinate fiducial-mark is specified in
more than one fiducial groups.
2089
2090
Skip is selected for the priority Pickup Data. The Pickup Priority is invalid.
The priority Pickup Data is out of the travel range. The Pickup Priority is invalid.
2091
Component codes in Pickup Data and in Pickup
Priority do not match.
The Pickup Priority is invalid.
Pickup Order is invalid because improper Priority
2092
Pickup is specified.
The number of Image capture/matching steps must
2093 Too many Image capture/matching steps.
be within 999.
2130
warp check is too wide. same line zone.
2131
Number of points for the global PCB warp check is
not proper.
For the global PCB warp check, one group needs 3 to
50 points in the same line zone (Y) and 2 to 20 groups
are available.
2097
The component height entered in the Tray Data is too
Enter the height, from the tray bottom to the
component surface, for the component height in the
low.
Tray Data.
Enter the height, from the tray bottom to the
2098
The component height entered in the Tray Data is too
low.
component surface, for the component height in the
Tray Data.
2099
Mounting locations of the reject conveyor and the
feeder are overlapped.
2100
The coordinate X may exceed the head movable
range by the compensation of the placement point.
Change the head No.
2101
The set position of the reject conveyor exceeds
allowable range.
Change the set position of the reject conveyor.
2102
Component outer size exceeds the capture limit of
Head 1,3,4,6.
Possible capture size of Head 1,3,4,6 is width 25mm
or less. Change the head No.
2103
The components are too large to perform multiple
pickup in a same cycle.
The multiple pickup will be divided in different pickup
cycle.
Multiple pickup is specified for the component with Specify single pickup for the component with multi
2104
multi view process.
The image data used for the pattern matching cannot
view process.
Use image codes individually or specify the center
2105
2107
be used with a different camera
The used supply unit ID is not specified in the header.
search
Specify the supply unit ID.
2108
The supply unit ID specified in the header and the ID
of the used supply unit do not match.
Specify the ID of the used supply unit or exchange it
for the supply unit of the correct ID.
Specify global fiducial when Correct local fiducial
2109 Global fiducial is not specified.
marks" is selected."
Locate the local fiducial mark(s) in the range of the
2110
A local fiducial mark(s) locates out of the range of 4-
point-global-fiducial.
global fiducial when Correct local fiducial marks" is
selected."
2111
No Check" is selected for the ball check method in
the BGA/CSP image data."
2112
The front camera is used to capture the image of the
component picked up from the rear side.
To improve production efficiency, use the rear
camera.
2113
The rear camera is used to capture the image of the
component picked up from the front side.
To improve production efficiency, use the front
camera.
2114
A front head is used for the component picked up
from the rear side.
Use a rear head.
2115
A rear head is used for the component picked up from
the front side.
Use a front head.
2116 The coordinates of Flux Station exceed the range.
Correct the coordinates of Flux Station or select a
proper head.
2117
The coordinates of Flux Station locate either within
the work range of 'ANC/Fx-C Area', or 'MX' tray
Check the coordinates of Flux Station entered in the
user parameter.
2118
The coordinates of Flux Station locate within the
PCB area.
Check the coordinates of Flux Station.
2119
Flux process will not be executed because 'Disable' is
selected for Flux Station in the user parameter.
2120
Flux process is enabled to execute prior to vision
process, however Reuse" is selected in the program."
Change the process order or select other than
Reuse"."
Wait time on the surface of Flux Station exceeds 10
2121
sec.
Laser is specified in Head, but Laser Measurement is
2122
not selected in Algorithm.
2123
2124
The coordinates of reference corner exceed the
The setting position of MSF exceeds allowable range.
2125
2126
Reject tray cannot be used.
PCB warp check point is out of range.
Too many points exist in one group to check local Maximum 4 points are allowed in one group to check
2127
PCB warp. local PCB warp.
Create 3 to 50 points in the same line zone for the
2128
Number of points within the same line zone for the
global PCB warp check is not proper.
global PCB warp check. Points within 5% range of
PCB length (X) are accepted as the same line zone.
2129
Check range of the PCB in length (X) direction for the
global PCB warp check is too narrow.
Check points in the same line zone for the global PCB
Check range must be wider than 60% length (X) of the
PCB for the global PCB warp check.
Distance between points must be within 50mm in the