2130 warp check is too wide. same line zone. 2131 Number of points for the global PCB warp check is not proper. For the global PCB warp check, one group needs 3 to 50 points in the same line zone (Y) and 2 to 20 groups a…

2094 Entered value in Pallet Data>Speed is too slow. Enter 100(10%) or higher speed.
2095
Component outer size exceeds the capture limit of
Head 1,4,5,8.
Possible capture size of Head 1,4,5,8 is width 11mm
or less. Change the head No.
2096 Set position of the reject conveyor is not proper. Set the reject conveyor at a feeder placeable station.
2056
The Repeat Offset data is not proper so that
dispense points may be overlapped.
2057
The setting position of PS-MS3 exceeds allowable
range.
Do not set the PS-MS3 on the 2 feeder stations from
both ends of the feeder bank.
2058
Pre-rotation function is disabled because coplanarity
check function is specified.
The tip of the nozzle will move down lower than the Check Z of placement data, thickness and Z of board
2059
board surface when it mounts a component. origin of board data.
Specify the correct Head unit corresponding to the
2060
2061
Different Head unit is specified. Tray unit or specify the correct Tray unit
corresponding to the Head unit.
This unit cannot handle the inspection head. Specify the unit that has an inspection function.
2062 A different head unit is used for Multiple Pickup.
The components having unequal Illumination and
Specify Multiple Pickup with heads in a same unit.
2063 Gain/Offset values within one cycle will be Still-
captured.
2064 A shared Fiducial Mark step has not been created.
Uncheck the Share the Fiducial Mark Information"
check box
2065
Specified line as a shared Fiducial Mark step is not
correct.
Create the shared Fiducial Mark step at the top line
in Placement&Mark Data.
Component outer size exceeds the capture limit of Possible capture size of Head 1,4,5,8 is width 8mm or
2066
Head 1,4,5,8. less. Change the head No.
Input proper PCB length or decrease the number of
2067 PCB length is too long.
Placement stages.
2068 PCB length exceeds the limit.
Less than the possible number of placement stages is
2069
selected.
You can increase the number of Placement stages.
2070 It exceeds the placement range of Head unit B.
Head unit B cannot use Shared fiducial marks on the
Change a head or select Head unit A.
2071
2072
machine mounting two Placement stages.
Beam camera recognition cannot be used. Change Centering" setting to use another camera."
Pickup No. is not correct. (The feeder may not be
2073
attached in the position.)
The component may interfere with the next nozzle
Check no obstacles at both sides of the feeder.
Divide the pickup cycle in different cycles or use
2074
because its size is too large. other head to pick up in order to avoid the collision.
2075 Multiple-view process assignment is not proper. Select a proper multiple-view process.
Shared Fiducial/Bad mark is invalid when Mount
2076
2077
Stage Count is 1.
No image code for Image capture is found.
Uncheck the Shared Mark check box.
Register an image code.
2078
2079
No image code for Image matching is found. Register an image code.
Placement steps exist prior to Image capture steps. Perform Image capture before starting placement.
2080
Placement other than BGA is found after Image
matching process.
Insert BGA placement steps right after Image
matching steps.
The number of Image capture and that of Image
2081
matching are not the same.
2082
The coordinates of Image capture and that of Image
matching do not match.
2083
2084
No fiducial mark process of this unit is found.
This Fiducial Group No. is not used.
Add fiducial mark steps.
2085
Board width (Y) of Board Data exceeds the limit
because of RTS-1.
2086
More than the number of heads is assigned in Pickup
Order.
Within the number of heads must be assigned in
Pickup Order.
Pickup Order is invalid because Pickup Priority is not
2087
specified.
2088
The same coordinate fiducial-mark is specified in
more than one fiducial groups.
2089
2090
Skip is selected for the priority Pickup Data. The Pickup Priority is invalid.
The priority Pickup Data is out of the travel range. The Pickup Priority is invalid.
2091
Component codes in Pickup Data and in Pickup
Priority do not match.
The Pickup Priority is invalid.
Pickup Order is invalid because improper Priority
2092
Pickup is specified.
The number of Image capture/matching steps must
2093 Too many Image capture/matching steps.
be within 999.

2130
warp check is too wide. same line zone.
2131
Number of points for the global PCB warp check is
not proper.
For the global PCB warp check, one group needs 3 to
50 points in the same line zone (Y) and 2 to 20 groups
are available.
2097
The component height entered in the Tray Data is too
Enter the height, from the tray bottom to the
component surface, for the component height in the
low.
Tray Data.
Enter the height, from the tray bottom to the
2098
The component height entered in the Tray Data is too
low.
component surface, for the component height in the
Tray Data.
2099
Mounting locations of the reject conveyor and the
feeder are overlapped.
2100
The coordinate X may exceed the head movable
range by the compensation of the placement point.
Change the head No.
2101
The set position of the reject conveyor exceeds
allowable range.
Change the set position of the reject conveyor.
2102
Component outer size exceeds the capture limit of
Head 1,3,4,6.
Possible capture size of Head 1,3,4,6 is width 25mm
or less. Change the head No.
2103
The components are too large to perform multiple
pickup in a same cycle.
The multiple pickup will be divided in different pickup
cycle.
Multiple pickup is specified for the component with Specify single pickup for the component with multi
2104
multi view process.
The image data used for the pattern matching cannot
view process.
Use image codes individually or specify the center
2105
2107
be used with a different camera
The used supply unit ID is not specified in the header.
search
Specify the supply unit ID.
2108
The supply unit ID specified in the header and the ID
of the used supply unit do not match.
Specify the ID of the used supply unit or exchange it
for the supply unit of the correct ID.
Specify global fiducial when Correct local fiducial
2109 Global fiducial is not specified.
marks" is selected."
Locate the local fiducial mark(s) in the range of the
2110
A local fiducial mark(s) locates out of the range of 4-
point-global-fiducial.
global fiducial when Correct local fiducial marks" is
selected."
2111
No Check" is selected for the ball check method in
the BGA/CSP image data."
2112
The front camera is used to capture the image of the
component picked up from the rear side.
To improve production efficiency, use the rear
camera.
2113
The rear camera is used to capture the image of the
component picked up from the front side.
To improve production efficiency, use the front
camera.
2114
A front head is used for the component picked up
from the rear side.
Use a rear head.
2115
A rear head is used for the component picked up from
the front side.
Use a front head.
2116 The coordinates of Flux Station exceed the range.
Correct the coordinates of Flux Station or select a
proper head.
2117
The coordinates of Flux Station locate either within
the work range of 'ANC/Fx-C Area', or 'MX' tray
Check the coordinates of Flux Station entered in the
user parameter.
2118
The coordinates of Flux Station locate within the
PCB area.
Check the coordinates of Flux Station.
2119
Flux process will not be executed because 'Disable' is
selected for Flux Station in the user parameter.
2120
Flux process is enabled to execute prior to vision
process, however Reuse" is selected in the program."
Change the process order or select other than
Reuse"."
Wait time on the surface of Flux Station exceeds 10
2121
sec.
Laser is specified in Head, but Laser Measurement is
2122
not selected in Algorithm.
2123
2124
The coordinates of reference corner exceed the
The setting position of MSF exceeds allowable range.
2125
2126
Reject tray cannot be used.
PCB warp check point is out of range.
Too many points exist in one group to check local Maximum 4 points are allowed in one group to check
2127
PCB warp. local PCB warp.
Create 3 to 50 points in the same line zone for the
2128
Number of points within the same line zone for the
global PCB warp check is not proper.
global PCB warp check. Points within 5% range of
PCB length (X) are accepted as the same line zone.
2129
Check range of the PCB in length (X) direction for the
global PCB warp check is too narrow.
Check points in the same line zone for the global PCB
Check range must be wider than 60% length (X) of the
PCB for the global PCB warp check.
Distance between points must be within 50mm in the

2171
Types of Priority nozzle and Substitute nozzle are
different.
Selection of Special Nozzle data of Priority nozzle
and Substitute nozzle must be the same.
2172 Coordinates of DotStation row cannot be changed. Keep coordinates of DotStaion 0.
2173 Components used in the program are not mounted.
2132
Check points in the same line zone for the global PCB
warp check is too close.
Distance between points must be wider than 5mm in
the same line zone.
Placement row exists prior to global PCB warp check
2133
rows.
Group No. of PCB warp check is specified prior to To use the same PCB warp check group, create PCB
2134
PCB warp check rows. warp check rows prior to placement rows.
2135 Group No. of PCB warp check is wrong. Available group Nos. of PCB warp check are 0-10000.
Data other than 0 is entered in Z coordiante of the If placement height may change due to PCB warp, use
2136
2137
PCB origin or of placement data.
PCB length is too short.
PCB warp tolerance" in the PCB data."
2138
2139
PCB thickness is out of spec.
The same offset value already exists in ST No. Offset.
2140 Still capture is selected.
To perform still capture, Z offset for vision process
must be entered in component advanced data.
Still capture and on-the-fly capture are prohibited to
2141
exist in one cycle. They will be divided into two
Multi view capture and on-the-fly capture are
2142 prohibited to exist in one cycle. They will be divided
into two cycles.
Pickup No. is not correct. (The feeder cannot be
2143
attached in the position.)
Check no obstacles at both sides of the feeder.
Select a fixed camera and do not use the scan
2144
2145
Component is too large and will hit the scan camera.
No fiducial mark process is found.
camera within this cycle.
Add fiducial mark steps.
2146 Original X and Y points of tray data are not entered.
Nozzle selection is not proper. It may cause pickup
Enter the coordinates of Original X and Y points of
tray data.
2147
error.
Check the nozzle No. and the component dimensions.
Sum of Pickup 'Z offset' + Feeder 'Feed height' +
2148
Cannot set the feeder because pickup point height
Package 'Height' must be 9mm or less. (Minus Z
exceeds 9mm.
offset is not added.)
2149
Cannot use F3 feeders and other type of feeders on
the same bank.
Check feeders.
2150 Comp Pitch is not proper. Select a proper Comp Pitch for the feeder.
2151 Dispense height is too low.
Dispense nozzle code is not registered in the
2152
dispense nozzle data.
2153
2154
Dispense check mode is not correct.
DotStation position is not proper.
Select Dispense & Check"."
2155
2156
Head does not reach DotStation. Mount DotStation at usable position.
Teach camera does not reach DotStation. Mount DotStation at usable position.
Create DotStation row in Pickup Data and specify
2157 DotStation is not registered in Pickup Data.
DotStation cannot be used in Placement data and
Station No.
2158
Component data.
2159 No global PCB warp check process is found. Add global PCB warp check process.
2160 The order of dispense and placement are not correct.
Correct the order so that dispense comes before
placement.
2161 Stacked component height exceeds 30mm.
2162 Syringe code is not registered in Dispense data.
Open Dispense from Manual menu and select Syringe
2163 Syringe code is not selected in Head Configuration.
code in Head Configuration.
2164 Dispense nozzle code is not registered in Syringe
More than one DotStation row is registered in Pickup
2165
data.
DotStation row must be one.
2166
2167
Laser head cannot reach DotStation.
Cannot mount DotStation because a feeder is within
the space.
Mount DotStation at proper position.
Relocate DotStation or the feeder.
2168 Dispense height is too high.
Maximum limit of dispensing and placement rows
2169
Total of dispensing and placement rows exceeds the
limit to perform Auto PCB warp check.
including repeat task rows is 10000 for Auto PCB
warp check. Select Manual for PCB warp check by
Figures (buffer/rigid) of Priority nozzle and Substitute
Same figure nozzle must be selected for Priority
2170
nozzle are different.
nozzle and Substitute nozzle.