M20_Ope_E - 第7页

Detailed safety precautions During mounter unloading, the center of gravity of the mounter may change due to a shift of the movable sections inside the mounter, so the mo unter may fall from the unloading equipment (fork…

100%1 / 518
inside the mounter. Serious injury can result. Also make sure non-operators are at a safe
distance from the machine. (Chapter 10 > Axis)
The Origin menu allows the specified axes to move. When executing this task, do not stick
head, hands, or other parts of the body inside the mounter. Serious injury can result. Also make
sure non-operators are at a safe distance from the machine. (Chapter 10 > Origin)
Turning on/off signal output in the Signal Output (Control) window allows an actuator to
move. When executing this operation, do not stick head, hands, or other parts of the body
inside the mounter. Serious injury can result. Also make sure non-operators are a safe distance
from the machine. (Chapter 10 > Signal I/O > Signal Output Control)
The Actuator menu allows the specified actuator to move. When executing actuator operation
via this menu, do not stick your head, hands, or other physical parts inside the mounter.
Serious injury can result. Also make sure non-operator are at a safe distance from the machine.
(Chapter 10 > Actuators)
Warm-up operation allows the specified machine parts to move. When executing warm-up
operation, do not stick head, hands, or other parts of the body inside the mounter. Serious
injury can result. Also make sure non-operators are at a safe distance from the machine.
(Chapter 10 > Warm-up)
Maintenance and Inspection
Turn off the main switch and circuit breaker before servicing the machine.
However, if maintenance or inspection needs to be carried out with the power turned ON,
ensure safety and take special care not to put your hands, head or any part of your body into
the mounter while the axes are moving.
Even after the main switch and circuit breaker are turned off, terminals for lead-in wires are
still live. Do not touch them to prevent electric shock.
Do not touch motors and motor drivers when they are hot.
Detailed safety precautions
During mounter unloading, the center of gravity of the mounter may change due to a shift of
the movable sections inside the mounter, so the mounter may fall from the unloading
equipment (forklift, etc.) and cause injuries. Always be sure to move the mounter with the XY
axes clamped with the jigs.
Improper installation of the mounter can cause mechanical or electrical hazards. Check the
methods used to install the mounter and the power connections.
It is assumed that the mounter will be used as a direct link in the production line.
If using the mounter separately, then the customer should install some sort of cover that
satisfies the requirements in [EN294/JISB9707] given below that ensure hands are kept away
from the board carry-in and carry-out openings.
Even when using the mounter as a direct link in the production line, there may be board
carry-in and carry-out openings where hands can reach inside.
In that case, the customer should also install some sort of cover that satisfies requirements in
[EN294/JISB9707] below to keep hands away from the board carry-in and carry-out openings.
[Safety standards EN294/JISB9707: Safe distance (upper limbs) from opening] are shown
below.
[Safety standards EN294/JISB9707: Safe distance (upper limbs) from opening]
e: Opening width Shape of opening
Rectangle (Square)
6e8 Safe distance 20(15)
8e10 80(25)
10e12 100(80)
12e20 120(120)
When not all of the feeders are used for feeder installation, then the operator may hurt himself
or herself by placing hands in the head movement range from the gap on the feeder stations
where no feeders are installed.
Please purchase the dummy feeders (option) and install them in the gap where there are no
feeders to prevent the operator’s hands from reaching inside.
Another method is to keep the operator’s hands away from these openings by installing some
sort of cover that meets the above requirements in [EN294/JISB9707].
Even if you turn off the main power switch, live voltage will still be supplied to the primary
power side and the wiring between the terminal block [XB11] and the main switch [QS11].
To prevent electrical shocks, do not remove or disassemble the mounter covers.
If the mounter is equipped with a UPS (option), then there will still be residual voltage even if
the main power switch is turned off.
So to prevent electrical shocks, do not remove or disassemble the mounter covers.
The regenerative resistor may reach high temperatures.
Touching the heat-sink or regenerative resistor may cause burns, so do not remove or
disassemble the mounter covers.
Different sections of the mounter have the following warning labels.
Read the message on the label and always comply with its instructions.