Command Groups T able 2-41: T rigger Commands (cont.) Command Description TRIGger:A:BUS:B<x>:FLEXray:E OFTYPE This command speci fi es the end of fi le type (static, dynamic or any) when triggering on the FlexRay bus…

Command Groups
Table 2-41: Trigger Commands (cont.)
Command
Description
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:
TYPe}:VALue
When the Ethernet trigger condition is set to MACLENgth, and the qualifier is
set to
LESSthan, MOREthan, EQual, UNEQual, LESSEQual or
MOREEQual, this command speci fies the 16–bit value to trigger on.
TRIGger:A:BUS:B<x>:ETHERnet:QTAG:VALue When the E thernet trigger condition is set to QTAG, this command specifies
the 32–bit Q-Tag value to trigger on.
TRIGger:A:BUS:B <x >:ETH E R net:QU ALifier This command specifies the qualifier to be used when the E thernet trigger
condition is set to
MACLENgth or DATa.
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:
ACKnum:VALue
When the Ethernet trigger condition is set to
TCPHeader, this command
specifies the 32–bit acknowledgement number that is to be used in the trigger
(along with the destination and source port addresses and the sequence
number).
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:
DESTinationport:VALue
When the Ethernet trigger condition is set
TCPHeader, this command
specifies the 16–bit destination port address value that is to be used in the
trigger (along with the acknowledgement value, source port address and the
sequence number).
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:
SEQnum:VALue
When the Ethernet trigger condition is set to
TCPHeader, this command
specifies the 32–bit sequence number that is to be used in the trigger (along
with the destination and source port addresses and the acknowledgement
value).
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:
SOUrceport:VALue
When the Ethernet trigger condition is set to
TCPHeader, this command
specifies the 16–bit source port address that is to be used in the trigger
(along with the destination port address, the sequence number and the
acknowledgement number).
TRIGger:A:BUS:B<x>:FLEXray:CONDition This command specifies the condition to use when triggering on a FlexRay
bus signal (start of frame, frame type, ID, cycle count, header, data, ID and
data, EOF, error).
TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:
HIVALue
This command specifies the high v alue when triggering on a FlexRay bus
cycle count field.
TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:
QUALifier
This command specifies the qualifier (<, >, =, <=, >=, not =, in range, out of
range) to use when triggering on the FlexRay bus cycle count field.
TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:
VALue
This command specifies the low value when triggering on the FlexRay bus
cycle count field.
TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue This command specifies the high value when triggering on the FlexRay bus
data field.
TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSet This command specifies the o ffset of the data string, in bytes, when triggering
on the FlexRay bus data field.
TRIGger:A:BUS:B<x>:FLEXray:DATa:QUALifier This command specifies the qualifier (<, >, =, <=, >=, not =, in range, out of
range) to use when triggering on the FlexRay bus data field.
TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe This command specifies the length of the data string, in bytes, when triggering
on the FlexRay bus data field.
TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue This command specifies the low value when triggering on the FlexRay bus
data field.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-83

Command Groups
Table 2-41: Trigger Commands (cont.)
Command
Description
TRIGger:A:BUS:B<x>:FLEXray:E OFTYPE This command specifies the end of fi le type (static, dynamic or any) when
triggering on the FlexRay bus EOF field.
TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE This command specifies the error type when triggering on the FlexRay bus
signal.
TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:
HIVALue
This command specifies the high value when triggering on the FlexRay bus
frame ID field.
TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:
QUALifier
This command specifies the qualifier to use w hen triggering on the FlexRay
bus frame ID field.
TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue This command specifies the low value when triggering on the FlexRay bus
frame ID field.
TRIGger:A:BUS:B<x>:FLEXray:FRAMEType This command specifies the frame type (normal, payload, null, sync or startup)
when triggering on the FlexRay bus signal.
TRIGger:A:BUS:B<x>:FLEX ray:HEADER:CRC This command specifies the CRC portion of the binary header string when
triggering on the FlexRay bus signal.
TRIGger:A:BUS:B<x>:FLEXray:HEADER:
CYCLEcount
This command specifies the cycle count portion of the binary header string
when triggering on the FlexRay bus header.
TRIGger:A:BUS:B<x>:FLEXray:HEADER:
FRAMEID
This command specifies the frame ID portion of the binary header string when
triggering on the FlexRay bus header.
TRIGger:A:BUS :B<x>:FLEX ray:HEADER:INDBits This command specifies the indicator bits portion of the binary header string
when triggering on the FlexRay bus header.
TRIGger:A:BUS:B<x>:FLEXray:HEADER:
PAYLength
This command specifies the payload length portion of the binary header string
when triggering on the FlexRay bus header.
TRIGger:A:BUS :B<x>:I2C:ADDRess:MODe This command speci fies the I2C address mode to 7 or 10-bit
TRIGger:A:BUS:B<x>:I2C:ADDRess:TYPe This command specifies the I2C address type to USER
TRIGger:A:BUS:B<x>:I2C:ADDRess:VALue This command specifies the binary address string used for the I2C trigger
TRIGger:A:BUS :B<x>:I2C:C ON Dition This command specifies the trigger condition for I2C trigger
TRIGger:A:BUS :B<x>:I2C:D ATa:DIRection This command specifies the I2C trigger condition valid on a READ, WRITE,
or either
TRIGger:A:BUS :B<x>:I2C:D ATa:SIZe This command specifies the length of the data string i n bytes to be used for
I2C trigger
TRIGger:A:BUS:B<x>:I2C:DATa:VALue This command speci fies the binary data string used for I2C triggering
TRIGger:A:BUS :B<x>:LIN:C ON Dition This command specifies the trigger condition for LIN
TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue This command specifies the binary data string to be used for LIN trigger
TRIGger:A:BUS:B<x>:LIN:D ATa:QUALifier This command specifies the LIN data qualifier
TRIGger:A:BUS :B<x>:LIN:D ATa:SIZe This command specifies the length of the data string i n bytes to be used for
LIN trigger
TRIGger:A:BUS:B<x>:LIN:DATa:VALue This command specifies the binary data s tring
TRIGger:A:BUS:B<x>:LIN:ERRTYPE This command specifies the error type
TRIGger:A:BUS :B<x>:LIN:ID entifier:VALue This comm and specifies the binary address string used for LIN trigger
2-84 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Command Groups
Table 2-41: Trigger Commands (cont.)
Command
Description
TRIGger:A:BUS:B<x>:MIL1553B :CO MMAND:
ADDRess:HIVALue
When the M IL-STD-1553 bus trigger condition is set to COMMAN D, and the
qualifier is set to
INrange or OUTrange, this command specifies the upper
limit of the range for the remote terminal address field.
TRIGger:A:BUS:B<x>:MIL1553B :CO MMAND:
ADDRess:QUALifier
When the MIL-STD-1553 bus trigger condition is set to COMMAND,this
command specifies the qualifier to be used with the remote terminal address
field.
TRIGger:A:BUS:B<x>:MIL1553B :CO MMAND:
ADDRess:VALue
When the MIL-STD-1553 bus trigger condition is set to COMMAND,and
the qualifier is set to
LESSthan, MOREthan, EQual, UNEQual,
LESSEQual
or MOREEQual, this command specifies the value of the 5–bit
remote terminal address to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :CO MMAND:
COUNt
When the MIL-STD-1553 bus trigger condition is set to COMMAND,this
command specifies the bit pattern for the 5–bit Word C ount/Mode Code
sub-address fi eld that is to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :CO MMAND:
PARity
When the MIL-STD-1553 bus trigger condition is set to COMMAND,this
command specifies the Command word parity that is to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :CO MMAND:
SUBADdress
When the MIL-STD-1553 bus trigger condition is set to COMMAND,this
command specifies the 5 bit s ub-address that is to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :CO MMAND:
TRBit
When the MIL-STD-1553 bus trigger condition is set to COMMAND,this
command specifies that the transmit/receive bit (bit 9) is to be used in the
trigger.
TRIGger:A:BUS:B<x>:MIL1553B :CONDition This command specifies a word type or condition within a MIL-STD-1553 bus
word to trigger on.
TRIGger:A:BUS:B<x>:MIL1553B :DATa:PARity When the MIL-STD-1553 bus trigger condition is set to DATa, this c ommand
specifies the data parity bit to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :DATa:VALue When the MIL-STD-1553 bus trigger condition is set to DATa, this command
specifies the data binary pattern to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :ERRTYPE When the MIL-STD-1553 bus trigger condition is set to ERRor, this command
specifies the signaling error type to be used in the trigger: Parity, Sync,
Manchester or Data.
TRIGger:A:BUS:B<x>:MIL1553B :STATus:
ADDRess:HIVALue
When the MIL-STD-1553 bus trigger condition is set to STATus, and the
qualifier is set to
INrange or OUTrange, this command specifies the upper
limit for the 5 bit remote terminal address fi eld of the Status word.
TRIGger:A:BUS:B<x>:MIL1553B :STATus:
ADDRess:QUALifier
When the MIL-STD-1553 bus trigger condition is set to STATus, this command
specifies the qualifier to be used with the address field.
TRIGger:A:BUS:B<x>:MIL1553B :STATus:
ADDRess:VALue
When the MIL-S TD-1553 bus trigger condition is set to STATus, and
the qualifier is set to
LESSthan, MOREthan, EQual, UNEQual,
LESSEQual
or MOREEQual, this command specifies the value of the 5–bit
remote terminal address to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :STATus:BIT:BCR When the MIL-STD-1553 bus trigger condition is set to STATus, this command
specifies the status word broadcast command received (BCR) bit value (bit
15) to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :STATus:BIT:
BUSY
When the MIL-STD-1553 bus trigger condition is set to STATus, this command
specifies the status word busy bit value (bit 16) to be used in the trigger.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-85