MDO3000 Programmer Manual.pdf - 第409页
Commands Listed in Alphabetical Order Syntax MASK:STANdard {DS1|DS1A|DS1 C|DS2|DS3|DS4NA| DS4XNA|STS1Pulse |STS1Eye|STS3 |STSX3|CLOCKC oax|CLOCKSymmetr ical|DSOContra|D SODouble |DSOSingle|D SOTiming|G703D S1|DS1Rate|DS2…

Commands Listed in Alphabetical Order
MASK:SOUrce
This command specifies the mask source waveform to be used during pass/fail
mask testing. Must be one of CH1 through CH4.
A series of examples showing how to use mask commands for typical tasks
is included in an appendix. (See page E-1, Mask/Limit Command Sequence
Examples.)
Conditions
This command requires a DPO4LMT application module for 4000 series models,
and an MDO3LMT application module for MDO3000 series models.
Group
Mask
Syntax
MASK:SOUrce {CH1|CH2|C H3|CH4}
MASK:SOUrce?
Related Commands
MASK:LOCk
Examples
MASK:SOUrce CH2 sets the source waveform for the mask to channel 2.
MASK:STANdard
This command replaces the existing mask, if any, with a specified standard mask.
There are three categories of standard masks: ANSI T1.102, ITU-T, and USB.
To ensure that Mask commands are enabled, use the command APPLication:TYPe
LIMITMask.
A series of examples showing how to use mask commands for typical tasks
is included in an appendix. (See page E-1, Mask/Limit Command Sequence
Examples.)
NOTE. The only argument enumerations available for the MDO3000 series
models are
CUSTom | LIMit | NONe | USER
.
Conditions
This command requires a DPO4LMT application module for 4000 series models,
or an MDO3LMT application module for MDO3000 series models.
Group
Mask
2-378 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Commands Listed in Alphabetical Order
Syntax
MASK:STANdard
{DS1|DS1A|DS1C|DS2|DS3|DS4NA|DS4XNA|STS1Pulse|STS1Eye|STS3
|STSX3|CLOCKCoax|CLOCKSymmetrical|DSOContra|DSODouble
|DSOSingle|D
SOTiming|G703DS1|DS1Rate|DS2RATECoax
|DS2RATESymmetrical|G703DS3|DS3Rate|E1Coax|E1Symmetrical
|E2|E3|HST1|HST2|HST3|HST4|HST5 |HST6|NONe |USER|LIMit}
MASK:STANdard?
Arguments
ANSI T1.102:
DS1 – DS1 1.544
Mb/s
DS1A – DS1A 2.048 Mb/s
DS1C – DS1C 3.152 Mb/s
DS2 – DS2 6.312 Mb/s
DS3 – DS3 44.736 Mb/s
DS4NA – DS4NA 139.26 Mb/s
DS4XNA – DS4NA Max Output 138.26 Mb/s
STS1Pulse – STS–1 Pulse 51.84 Mb/s
STS1Eye – STS–1 Eye 51.84 Mb/s
STS3 – STS–3 155.52 Mb/s
STSX3 – STS–3 Max Output 155.52 Mb/s
ITU-T:
CLOCKCoax – Clock Interface Coaxial Pair 2.048 Mb/s
CLOCKSymmetrical – Clock Interface Symmetrical Pair 2.048 Mb/s
DSOContra – DSO Data Contradirectional 64 kb/s
DSODouble – DSO Double 64 kb/s
DSOSingle – DSO Single 64 kb/s
DSOTiming – DSO Timing 64 kb/s
G703DS1 – DS1 G.7031.544 Mb/s
DS1Rate –DS1OldRate1.544Mb/s
DS2RATECoax – DS2 Rate Coaxial Pair 6.312 Mb/s
DS2RATESymmetrical – DS2 Rate Symmetrical Pair 6.312 Mb/s
G703DS3 – DS3 G.703 44.736 Mb/s
DS3Rate – DS3 Old Rate 44.736 Mb/s
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-379

Commands Listed in Alphabetical Order
E1Coax –E1Coax
ial Pair 2.048 Mb/s
E1Symmetrical – E1 Symmetric Pair 2.048 Mb/s
E2 – E2 8.448 Mb/s
E3 – E3 34.368 Mb/s
USB:
HST1 – HS:T1 480 Mb/s
HST2 –HS:T
1480Mb/s
HST3 – HS:T1 480 Mb/s
HST4 – HS:T1 480 Mb/s
HST5 – HS:T1 480 Mb/s
HST6 – HS:T1 480 Mb/s
In addition to the standard masks,
LIMit, USER, and NONe can be input as well.
Returns
MASK:STANdard? returns one of the following:
NONE indicates that the mask application is not active.
USER indicates one of the following:
the current mask has been recalled from a file or
the current mask has been created from scratch using the MASK commands or
the current mask has been created by modifying one of the built-in standard
telecommunications masks.
LIMIT indicates that the mask is a limit test (template) mask.
DS1, etc. indicates that the current mask is one of the built-in standard masks.
Examples
MASK:STANdard DSO Double replaces the existing mask, if any, with a
standard ITU-T DSO Double mask.
MASK:STANdard? might return NONE, indicating that the mask application
is not currently active.
MASK:STOPOnviolation
This command stops the waveform acquisitions upon the first occurrence
of a waveform violation. You can also specify an action to be performed
when acquisitions are stopped by using the commands such as MASK:TESt:
2-380 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual