MDO3000 Programmer Manual.pdf - 第48页
Command Groups T able 2-18: Bus Commands (cont.) Commands Description BUS:B<x>:RS232C:P ARity This command speci fi es parity for the RS-232 bus BUS:B<x>:RS232C:POLarity This command speci fi es the polarity fo…

Command Groups
Table 2-18: Bus Commands (cont.)
Commands Description
BUS:B<x>:ETHERnet:SOUrce:
DMINus
This command specifies the Ethernet data source for D- input for single-ended probing.
BUS:B<x>:ETHERnet:SOUrce:
DPLUs
This command specifies the Ethernet data source for the D+ input for single-ended probing.
BUS:B<x>:ETHERnet:TYPe This command specifies the Ethernet standard type: 10Base-T o r 100Base-T.
BUS:B<x>:FLEXray:BITRate This command specifies the bit rate for the FlexRay bus signal
BUS:B<x>:FLEXray:CHannel This command specifies the FlexRay bus ID format
BUS:B<x>:FLEXray:SIGnal This command specifies the FlexRay bus standard
BUS:B<x>:FLEXray:SOUrce This command specifies the FlexRay bus data source
BUS:B<x>:I2C:ADDRess:RWINClude Sets and returns whether the read/write bit is included in the address
BUS:B<x>:I2C{:CLOCk|:SCLk}:
SOUrce
This command specifi es the I2C bus SCLK source
BUS:B<x>:I2C{:DATa|:SDAta}:
SOUrce
This command specifies the I2C bus SDATA source
BUS:B<x>:LABel This command specifies the waveform label for the specifi ed bus
BUS:B<x>:LIN:BITRate This command specifies the bit rate for the LIN bus.
BUS:B<x>:LIN:IDFORmat This command specifi es the LIN bus ID format
BUS:B<x>:LIN:POLarity This command specifies the LIN bus polarity
BUS:B<x>:LIN:SAMPLEpoint This command specifies the point to sample during each bit period, as a percent, for the
LIN bus.
BUS:B<x>:LIN:SOUrce This command speci fies the LIN bus data source
BUS:B<x>:LIN:STANDard This command specifies the LIN bus standard
BUS:B<x>:MIL1553B:POLarity This command sets the MIL-STD-1553 bus polarity to normal or inverted.
BUS:B<x>:MIL1553B:
RESPonsetime:MAXimum
This command specifies the maximum response time to a valid command issued for the
MIL-STD-1553 bus.
BUS:B<x>:MIL1553B:
RESPonsetime:MINimum
This command specifies the minimum response time to a valid command issued for the
MIL-STD-1553 bus.
BUS:B<x>:MIL1553B:SOUrce This command specifies the source for differential input for the MIL-STD-1553 bus.
BUS:B<x>:PARallel:BIT<x>:SOUrce This command specifies the bit source for the parallel bus.
BUS:B<x>:PARallel:CLOCk:EDGE This command specifies the clock edge for the parallel bus
BUS:B<x>:PARallel:CLOCk:
ISCLOCKed
This command specifies the state of the clock function for the parallel bus.
BUS:B<x>:PARallel:CLOCk:SOUrce This command speci fies the clock source waveform for the parallel bus.
BUS:B<x>:PARallel:WIDth This command specifies the number of bits to use for the width of the parallel bus.
BUS:B<x>:POSition This command specifies the position of the bus waveform on the display.
BUS:B<x>:RS232C:BITRate This command specifies the bit rate for the RS-232 bus.
BUS:B<x>:RS232C:DATABits This command specifies the number of bits in the data frame for the RS-232 bus.
BUS:B<x>:RS232C:DELIMiter This command specifies the delimiting value for a packet on the RS-232 bus.
BUS:B<x>:RS232C:DISplaymode This command specifies the display mode for the RS-232 bus (frame or packet).
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-17

Command Groups
Table 2-18: Bus Commands (cont.)
Commands Description
BUS:B<x>:RS232C:PARity This command specifies parity for the RS-232 bus
BUS:B<x>:RS232C:POLarity This command specifies the polarity for the RS-232C bus
BUS:B<x>:RS232C:RX:SOUrce This command specifies the RX source waveform for the RS-232 bus.
BUS:B<x>:RS232C:TX:SOUrce This command specifies the TX source waveform for the RS-232 bus.
BUS:B<x>:SPI:BITOrder This command specifies the bit order for the SPI bus
BUS:B<x>:SPI{:CLOCk|:SCLk}:
POLarity
This command specifies the SCLK polarity for the SPI bus.
BUS:B<x>:SPI{:CLOCk|:SCLk}:
SOUrce
This command specifies the SCLK source for the SPI bus.
BUS:B<x>:SPI:DATa{:IN|:MISO}:
POLarity
This command specifies the MISO polarity for the SPI bus.
BUS:B<x>:SPI:DATa{:IN|:MISO}:
SOUrce
This command specifies the MISO source for the SPI bus.
BUS:B<x>:SPI:DATa{:OUT|:MOSI}:
POLarity
This command specifies the MOSI polarity for the SPI bus.
BUS:B<x>:SPI:DATa{:OUT|:MOSI}:
SOUrce
This command specifies the MOSI s ource for the SPI bus.
BUS:B<x>:SPI:DATa:S IZe This command specifi es the number of bits per word (data size) for the specified SPI bus.
BUS:B<x>:SPI:FRAMING This command specifies the type of framing to use for the SPI bus.
BUS:B<x>:SPI:IDLETime This command specifies the idle time, in seconds, for the SPI bus.
BUS:B<x>:SPI{:SELect|:SS}:
POLarity
This command specifies the polarity for the SPI bus.
BUS:B<x>:SPI{:SELect|:SS}:SOUrce This command specifies the source waveform for the SPI bus.
BUS:B<x>:STATE This command specifi es the on/off state of the bus.
BUS:B<x>:TYPe This command specifies the bus type
BUS:B<x>:USB :BITR a te This command specifies the bit rate for the USB bus.
BUS:B<x>:USB:PRObe This command specifies the type of probe connected to the USB bus.
BUS:B<x>:USB:SOUrce:DIFFerential This command specifies the source waveform for the eUSB bus when using a differential
probe.
BUS:B<x>:USB:SOUrce:DMINus This command speci fies the source waveform for the USB bus D- input.
BUS:B<x>:USB:SOUrce:DPLUs This command specifies the source for the USB D+ input.
BUS:LOWerthreshold:CH<x> This command specifies the lower threshold for each channel.
BUS:LOWerthreshold{:MATH|:
MATH1}
This command specifies the lower threshold for the math w aveform.
BUS:LOWerthreshold:REF<x> This command sets the lower threshold for each reference waveform.
BUS:THReshold:CH<x> This command specifies the threshold for a channel.
BUS:THReshold:D<x> This command specifies the threshold for a digital channel.
BUS:UPPerthreshold:CH<x> This command specifies the upper threshold for each channel.
2-18 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Command Groups
Table 2-18: Bus Commands (cont.)
Commands Description
BUS:UPPerthreshold{:MATH|:
MATH1}
This command specifies the upper threshold for the math waveform.
BUS:UPPerthreshold:REF<x> This command sets the upper threshold for each reference waveform.
Calibration and Diagnostic Command Group
The Calibration and Diagnostic commands provide information about the
current state of oscilloscope calibration. They also initiate internal signal path
calibration (SPC) or execute diagnostic tests. Commands that are specific to
factory calibration are not described in this manual. Instead, they are described
in the Service Manual Documentation CD-ROM in PDF format. You can also
order a printed copy.
Table 2-19: Calibration and Diagnostic Commands
Command
Description
*CAL? Instructs the oscilloscope to perform self-calibration and returns the oscilloscope self
calibration status.
CALibrate:FACtory:STATus? Returns the factory calibration status value saved in nonvolatile memory.
CALibrate:FACtory:STATus:AFG? Returns the factory calibration status for the Arbitrary F unction Generator portion of the
instrument, if present.
CALibrate:FACtory:STATus:RF? Returns the factory calibration status value saved in nonvolatile memory for the RF portion
of the oscilloscope.
Available on m ixed domain oscilloscope models with R F enabled.
CALibrate:FACtory:STATus:SCOPE? Returns the factory calibration status value saved in nonvolatile memory for the non-RF
portion of the oscilloscope.
CALibrate:INTERNal Starts a signal path compensation
CALibrate:INTERNal:STARt Starts the internal signal path calibration.
CALibrate:INTERNal:STATus? Returns the current status of the internal signal path calibration.
CALibrate:INTERNal:STATus:RF? This query returns the status of the last SPC run for the RF portion of the instrument:
(doesn't include the analog channels).
Available on m ixed domain oscilloscope models with R F enabled.
CALibrate:INTERNal:STATus:
SCOPE?
This query returns the status of the last SPC run for the oscilloscope portion of the
instrument (doesn't include the RF portion).
CALibrate:RESults? Returns the status of all calibration subsystems without performing an SPC operation.
CALibrate:RESults:FACtory? Returns the status of internal and factory calibration.
CALibrate:RESults:FACtory:AFG? This query returns the factory calibration status for the Arbitrary Function Generator portion
of the instrument, if present.
CALibrate:RESults:FACtory:RF? This query returns the factory calibration status for the RF portion of the instrument,
if present.
Available on m ixed domain oscilloscope models with R F enabled.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-19