MDO3000 Programmer Manual.pdf - 第512页

Commands Listed in A lphabetical Order NOTE. The query r eturns NA t he harmonic limit does not apply . Conditions This command requires a DPO4PWR applic ation module for 4000 series models , or an MDO3PWR application mo…

100%1 / 1158
Commands Listed in Alphabetical Order
POWer:HARMon
ics:RESults:IEC:FUNDamental? (Query Only)
Returns the IEC fundamental current used in calculating limits.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:HARMonics:RESults:IEC:FUNDamental?
Examples
POWER:HARMONICS:RESULTS:IEC:FUNDAMENTAL? might return
:POWER:HARMONICS:RESULTS:IEC:FUNDAMENTAL 1.0 indicating that the
IEC fundamental frequency is set to 1.0 A.
POWer:HARMonics:RESults:IEC:HARM3ALTernate? (Query Only)
Returns the IEC harmonics test result for the 3rd harmonic.
NOTE. The query returns NA if the limit does not apply.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:HARMonics:RESults:IEC:HARM3ALTernate?
Returns
PASS, FAIL,orNA.
Examples
POWER:HARMONICS:RESULTS:IEC:HARM3ALTERNATE? might return
POWER:HARMONICS:RESULTS:IEC:HARM3ALTERNATE PASS indicating the
test result.
POWer:HARMonics:RESults:IEC:HARM5ALTernate? (Query Only)
Returns the overall harmonics test result for the 5th harmonic.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-481
Commands Listed in Alphabetical Order
NOTE. The query
returns NA the harmonic limit does not apply.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR
application module for MDO3000 series models.
Group
Power
Syntax
POWer:HARMonics:RESults:IEC:HARM5ALTernate?
Returns
PASS, FAIL,orNA.
Examples
POWER:HARMONICS:RESULTS:IEC:HARM5ALTERNATE? might return
POWER:HARMONICS:RESULTS:IEC:HARM5ALTERNATE PASS indicating the
test result.
POWer:HARMonics:RESults:IEC:POHC? (Query Only)
Returns the IEC POHC measurement.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:HARMonics:RESults:IEC:POHC?
Examples
POWER:HARMONICS:RESULTS:IEC:POHC? might return
:POWER:HARMONICS:RESULTS:IEC:POHC 0.5 indicating that the
IECPOHCissetto0.5A.
POWer:HARMonics:RESults:IEC:POHL? (Query Only)
Returns the IEC POHL measurement.
Conditions
This command requires a DPO4PWR application modu
le for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
2-482 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual
Commands Listed in Alphabetical Order
Group
Power
Syntax
POWer:HARMonics:RESults:IEC:POHL?
Examples
POWER:HARMONICS:RESULTS:IEC:POHL? might return
:POWER:HARMONICS:RESULTS:IEC:POHL 0.5 indicating that the
IEC POHL is set to 0.5 A.
POWer:HARMonics:RESults:IEC:POWer? (Query Only)
Returns the IEC input power that is used to calculate limits.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:HARMonics:RESults:IEC:POWer?
Examples
POWER:HARMONICS:RESULTS:IEC:POWER? might return
:POWER:HARMONICS:RESULTS:IEC:POWER 5 indicating that the
IEC power is set to 5 W.
POWer:HARMonics:RESults:IEC:POWERFactor? (Query Only)
Returns the IEC power factor measurement.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:HARMonics:RESults:IEC:POWERFactor?
Examples
POWER:HARMONICS:RESULTS:IEC:POWERFACTOR? might return
:POWER:HARMONICS:RESULTS:IEC:POWERFACTOR 9.1900E+37 indicating
that the IEC power factor is set to 9.1900E+37.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-483