Commands Listed in Alphabetical Order Examples POWER:SWLOSS: CONDCALCMETHOD RDSon sets the conduction calculation method to RDSon. POWER:SWLOSS :CONDCALCMETHO D ? might return :POWER:SWLOSS :CONDCALCMETHOD VOLT indicatin…

Commands Listed in Alphabetical Order
POWer:STATIs
tics:WEIghting
Sets the number of samples which are included for the statistics computations
for mean and the standard deviation. Performs the same function as the
MEASUrement
:STATIstics:WEIghting command.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:STATIstics:WEIghting <NR1>;Ranges {L,2,1000}
POWer:STATIstics:WEIghting?
Arguments
<NR1> is the number of samples used for the mean and standard deviation
statistical accumulations
Examples
POWER:STATISTICS:WEIGHTING 4 sets statistical weighting to four samples.
POWER:STATISTICS:WEIGHTING ? might return
:POWER:STATISTICS:WEIGHTING 4 indicating that statistics weighting is
currently set to 4 samples.
POWer:SWLoss:CONDCALCmethod
This command specifies the power application switching loss conduction
calculation method.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:SWLoss:CONDCALCmethod {VOLTage|RDSon|VCEsat}
POWer:SWLoss:CONDCALCmethod?
Arguments
VOLTage sets voltage as the conduction calculation method.
RDSon sets RDSon as the conduction calculation method.
VCEsat sets VCEsat as the conduction calculation method.
2-518 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Commands Listed in Alphabetical Order
Examples
POWER:SWLOSS:
CONDCALCMETHOD RDSon
sets the conduction calculation
method to RDSon.
POWER:SWLOSS
:CONDCALCMETHOD ?
might return
:POWER:SWLOSS:CONDCALCMETHOD VOLT indicating that the conduction
calculation method is set to Voltage.
POWer:SWLo
ss:CONDuction:ENERGY:MAX? (Query Only)
Returns the maximum conduction energy for switching loss calculation.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:SWLoss:CONDuction:ENERGY:MAX?
Examples
POWER:SWLOSS:CONDUCTION:ENERGY:MAX? might return
:POWER:SWLOSS:CONDUCTION:ENERGY:MAX 1 indicating that the
maximum conduction energy switching loss calculation is set to 1 J.
POWer:SWLoss:CONDuction:ENERGY:MEAN? (Query Only)
Returns the mean conduction energy in the conduction period for the switching
loss calculation.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:SWLoss:CONDuction:ENERGY:MEAN?
Examples
POWER:SWLOSS:CONDUCTION:ENERGY:MEAN? might return
:POWER:SWLOSS:CONDUCTION:ENERGY:MEAN 1 indicating that the mean
conduction energy switching loss calculation is set to 1 J.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-519

Commands Listed in Alphabetical Order
POWer:SWLoss
:CONDuction:ENERGY:MIN? (Query O nly)
Returns the minimum conduction energy for the switching loss calculation.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:SWLoss:CONDuction:ENERGY:MIN?
Examples
POWER:SWLOSS:CONDUCTION:ENERGY:MIN? might return
:POWER:SWLOSS:CONDUCTION:ENERGY:MIN 1 indicating that the
minimu
m conduction energy switching loss calculation is set to 1 J.
POWer:SWLoss:CONDuction:POWer:MAX? (Query Only)
Returns the maximum conduction power for the switching loss calculation.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:SWLoss:CONDuction:POWer:MAX?
Examples
POWER:SWLOSS:CONDUCTION:POWER:MAX? might return
:POWER:SWLOSS:CONDUCTION:POWER:MAX 1 indicating that the
maximum conduction power switching loss calculation is set to 1 W.
POWer:SWLoss:CONDuction:POWer:MEAN? (Query Only)
Returns the mean conduction power for the switching loss calculation.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
2-520 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual