Command Groups
Table 2-30: Mark Commands (cont.)
Command Description
MARK:TOTal?
Returns how many marks are used
MARK:USERLIST The command creates a single user mark on a waveform in the time domain. The arguments
consist of an enumeration specifying the source waveform, followed by 7 time mark
parameters. You can create up to 1,024 marks. To save all the marks to memory, use
the command
MARK:SAVEALL TOUSER.
Mask Command Group
Use the commands in the Mask Command Group to perform mask and limit
testing, useful for long-term signal monitoring, characterizing signals during
design, or testing on a production line. The commands simplify many tasks, such
as conducting pass/fail tests in search of glitches or other waveform anomalies,
comparing a signal against a known good signal, or against a standard or custom
mask,
counting hits against specific mask segments, and much more.
NOTE. In order to use Mask commands, you need to install an optional Limit and
mask test application module, Tektronix part number DPO4LMT. Also, ≥350 MHz
bandwidth models are recommended for telecommunication standards >55 Mb/s.
NOTE. To ensure that Mask commands are enabled, use the command
APPLication:TYPe LIMITMask.
There are three categories of masks available:
N
OTE. Standard mask support is not available for the MDO3000 series models.
Standard The instrument has a built-in set of pre-defined standard
telecommunications masks (see the
MASK:STANdard command for a complete
list). Although these masks are non-editable, they can be copied and used to
initialize user-defined custom masks.
Limit Test: Limit testing is used to compare a tested signal against a known good
or "golden" version of the same signal with user-defined vertical and horizontal
tolerances. These non-editable masks are created using a Reference waveform or
template. Use the
MASK:TEMPLate commands for limit testing.
Custom: (also referred to in this document as “user mask”). You can create
custom masks and tailor them to your own specific testing requirements. These
commands provide granular control over the points of the mask and offer a
variety of testing options. For instance, you can specify test duration either by
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-31

Command Groups
number of wavef
orms or by time, or specify a violation threshold that must be
met before considering a test a failure, or specify an action (such as writing to a
file or sending an SRQ) that is to be performed upon a violation, a test failure,
or test completion. Use MASK:CUSTom andthenthe
:MASK:USER commands
to create user-defined custom masks.
A series of examples showing how to use mask commands for typical tasks
is included as an appendix. (See page E-1, Mask/Limit Command Sequence
Examples.)
Table 2-31
: Mask commands
Command
Descripti
on
APPLicat
ion:TYPe
When a mask/limit or power test application module is installed, one of the associated test
types is always selected by default. This command allows the test type to be changed
from the
default.
MASK:CO
Py:SOUrce
Specifie
s the standard mask that is to be copied to a user created custom mask.
MASK:C
OPy:USER
Copies
the specified standard mask to a user created custom mask.
MASK:C
OUNt
Resets
to zero the number of hits and failures for all mask segments.
MASK:
COUNt:FAILURES?
Retur
ns the number of pass/fail mask tests that have failed
MASK
:COUNt:HITS?
This
query returns the sum of all hits in all mask segments.
MASK
:COUNt:SEG<x>:HITS?
This
query returns the number of hits for the specified mask segment.
MAS
K:COUNt:TESTS?
Ret
urns the number of pass/fail tests that have occurred
MAS
K:COUNt:VIOLATIONS?
Ret
urns the number of test violations that have occurred i n the current pass/fail test.
MA
SK:COUNt:WAVEFORMS?
Re
turns the number of waveforms that have been acquired and processed during pass/fail
mask testing.
MASK:CUSTom Sets the user-defined custom mask to its initialized state, or copies the currently active
mask to the user-defined custom mask.
MASK:DISplay Controls whether a user-defined custom mask is displayed on the screen.
MASK:LOCk Locks the mask to the waveform so that any changes made to the horizontal and/or vertical
scale settings of the w aveform will redraw the mask segments in proportion.
MASK:MARgin:PERCent Sets or returns the tolerance for the mask test. A positive value expands the m ask and a
negative margin shrinks the m ask by the specified percentage.
MASK:SOUrce Specifies the mask source waveform to be used during pass/fail mask testing
MASK:STANdard Replaces the existing m ask, if any, with a specified standard mask.
MASK:STOPOnviolation Stops the waveform acquisitions upon the first occurrence of a waveform violation.
MASK:TEMPLate:CREATEmask Causes a template m ask to be created for limit testing, based on the s ettings of the
MASK:TEMPLate:SOUrce, MASK:TEMPLate:TOLerance:H ORizontal, and
MASK:TEMPLate:VERTical commands.
MASK:TEMPLate:SOUrce Specifies the source waveform to be used to create a m ask template for limit testing.
MASK:TEMPLate:TOLerance:
HORizontal
Specifies the +/- horizontal limit (tolerance) for a mask template to be used for limit testing.
MASK:TEMPLate:TOLerance:
VERTical
Specifies the +/- vertical limit (tolerance) for a mask template to be used for limit testing.
2-32 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Command Groups
Table 2-31: Mask commands (cont.)
Command
Description
MASK:TESt:AUXout:COMPLetion Causes the instrument to send a TTL signal to the AUX:out port whenever a pass/fail
mask test completes.
MASK:TESt:AUXout:FAILure Causes the instrument to send a T TL signal to the AUX:out port whenever a pass/fail
mask test fails.
MASK:TESt:COMPLetion:CRITerion Specifies the criterion to be used for test completion (either by waveform or time) during
pass/fail mask testing.
MASK:TESt:DELay Specifies the amount of time, in seconds, the instrument should wait after the start of
pass/fail mask testing before it evaluates the waveforms.
MASK:TESt:HARDCopy Causes the instrument to generate a screen hard copy to the default printer as soon as a
pass/fail mask test fails, using the current instrument hard copy settings
MASK:TESt:REPeat Causes the mask test cycle to continuously repeat upon the completion of the previous
test cycle.
MASK:TESt:SAVEIMAG E Causes the instrument to copy the screen image to a U SB media file or a mounted network
drive if a pass/fail mask test fails.
MASK:TESt:SAVEWFM Copies the waveform data from all active channels to a file if a pass/fail m ask test fails.
MASK:TESt:SRQ:CO MPLetion Causes the instrument to send an SRQ command when a pass/fail mask test completes
MASK:TESt:SRQ:FAILure Causes the instrument to send an SRQ command when a pass/fail mask test fails.
MASK:TESt:STATE Turns the pass/fail mask test on or off.
MASK:TESt:STATus? Indicates the result of a pass/fail mask test.
MASK:TESt:STOP:FAILure Causes the instrument to stop acquiring data when a pass/fail mask test fails.
MASK:TESt:THReshold Specifies the number of failed tested waveforms needed in a pass/fail mask test to cause
the test status to change to ‘Failing’.
MASK:TESt:TIME Specifies the duration, in seconds, the instrument should run a pass/fail mask test.
MASK:TESt:WAVEform Specifies the number of waveforms the instrument should test during a pass/fail mask test.
MASK:USER:AMPLitude Specifies the nominal pulse amplitude, in volts, to be used for a user-defined custom mask.
MASK:USER:HSCAle Specifies the nominal timing resolution, in time/division, to be used to draw a user-defined
custom mask pulse shape.
MASK:USER:HTRIGPOS Specifies the nominal trigger position (pulse leading edge) to be used to draw a user-defined
custom mask, as a fraction o f the display width.
MASK:USER:LABel This command specifies a user-defined label for a custom mask.
MASK:USER:RECOrdlength Specifies the nominal record length to be used for pulse mask testing with a user-defined
custom mask.
MASK:USER{:SEG<x>|:MASK<x>} This command deletes the specified mask segment from the current mask segment. There
canbeupto8segments.
MASK:USER{:SEG<x>|:MASK<x>}:
NR_Pt?
This query returns the number of points that make up the specified mask segment of a
user-defined custom mask. There can be up to 8 segments.
MASK:USER{:SEG<x>|:MASK<x>}:
POINTS
This command specifies the x and y coordinates of the points that make up the segment
1–8. The units are normal waveform units. The x-coordinate is specified relative to the
trigger. The points are specified as a sequence of (x,y) points which traverse the boundary
of the s egment in a counter-clockwise direction.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-33