Commands Listed in Alphabetical Order
SEARCH:SEARC
H<x>:TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue
This command specifies the low value to use when searching on the FlexRay bus
frame ID field. (Use SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:
FRAMEID:HIV
ALue to set the high value.) The search condition needs to be set
to IDentifier (using SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:
CONDition).
SEARCH<x> is the search number, which is always 1, and B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue
<QString>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue?
Arguments
<QString> is a quoted string representing the binary data string used for FlexRay
frame ID low value.
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:FRAMEID:VALUE
“11001101010”
sets the value of the frame ID is 11001101010.
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:FRAMEID:VALUE? might
return
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:FRAMEID:VALUE
"10110010101"
indicating the value of the frame ID is 10110010101.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:FRAMEType
This command specifies the frame type (normal, payload, null, sync or startup) to
use when searching on FlexRay bus data. The search condition needs to be set to
FRAMEType (using SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:
CONDition).
SEARCH<x> is the search number, which is always 1, and B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Search
2-658 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual
Commands Listed in Alphabetical Order
Syntax
SEARCH:SEARCH
<x>:TRIGger:A:BUS:B<x>:FLEXray:FRAMEType
{NORMal|PAYLoad|NULL|SYNC|STARTup}
SEARCH:SEARC
H<x>:TRIGger:A:BUS:B<x>:FLEXray:FRAMEType?
Arguments
NORMal sets the frame type to normal.
PAYLoad sets the frame type to payload.
NULL sets the frame type to NULL.
SYNC sets the frame type to sync.
STARTup sets the frame type to start up.
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:FRAMETYPE STARTUP
sets the FlexRay frame type to startup.
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:FRAMETYPE? might return
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:FRAMETYPE NORMAL
indicating the FlexRay frame type is normal.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC
This command specifies the CRC portion of the binary header string to be used
when searching on FlexRay bus data. The search condition needs to be set
to HEADer (using SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:
CONDition).
SEARCH<x> is the search number, which is always 1, B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:HEAD
ER:CRC
<QString>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:HEADER:CRC?
Arguments
<QString> is a quoted string representing the CRC portion of the binary header
string used for FlexRay search.
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:HEADER:CRC
“00110010101”
sets the CRC protion of the binary header string 00110010101.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-659
Commands Listed in Alphabetical Order
SEARCH:SEARCH
1:TRIGGER:A:BUS:B1:FLEXRAY:HEADER:CRC?
might
return
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:HEADER:CRC
"XXXXXXXXXXX"
indicating the CRC protion of the binary header string is don't
cares.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCLEcount
This command specifies to use the cycle count portion of the binary header string
when searc
hing on the FlexRay bus header. The search condition needs to be set
to HEADer (using SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:
CONDition).
SEARCH<x> is the search number, which is always 1, and B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:HEADER:
CYCLEcount <QString>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:HEADER:
CYCLEcount?
Arguments
<QString> is a quoted string representing the cycle count portion of the binary
header string used for FlexRay search.
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:HEADER:CYCLECOUNT
“001101”
sets the cycle count to 001101.
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:HEADER:CYCLECOUNT?
might return
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:HEADER:CYCLECOUNT
"XXXXXX"
indicating the cycle count is don't cares.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID
This command specifies to use the frame I
D portion of the binary header string
when searching on the FlexRay bus header. The search condition needs to be set
to HEADer (using SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:
CONDition).
SEARCH<x> is the search number, which is always 1, and B<x> .
2-660 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual