Commands Listed in A lphabetical Order OFF sets the val ue to 0. ON sets the value to 1. Examples SEARCH:SEARCH 1:TRIGger:A:BUS: B1:MIL1553B:COM MAND:PARity ZERo sets the Command word parity bit to 0. SEARCH:SEARCH 1:TRI…

Commands Listed in Alphabetical Order
SEARCH:SEARCH
<x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:
SUBADdress
SEARCH:SEARC
H<x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit
Arguments
QString is a quoted string of up to 5 characters, where the allowable characters
are 0, 1 and X.
Examples
SEARCH:SEARCH1:TRIGger:A:BUS:B1:MIL1553B:COMMAND:COUNt
“01000”
sets the bit pattern for the Word Count/Mode Code field to 01000.
SEARCH:SEARCH1:TRIGger:A:BUS:B1:MIL1553B:COMMAND:COUNt? might
return “XXXXX”.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity
When the MIL-STD-1553 bus search condition is set to COMMAND, this command
specifies the Command word parity that is to be used in the search.
SEARCH<x>
is the search number, which is always 1, and B <x>
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity
{0|1|X|ZERo|ONE|NOCARE|OFF|ON}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:PARity?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:CONDition
Arguments
0
1
X
sets the value to X (“don’t care”) which is the default.
ZERO sets the value to 0.
ONE sets the value to 1.
NOCARE sets the value to X (“don’t care”) which is the default.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-675

Commands Listed in Alphabetical Order
OFF sets the val
ue to 0.
ON sets the value to 1.
Examples
SEARCH:SEARCH1:TRIGger:A:BUS:B1:MIL1553B:COMMAND:PARity ZERo
sets the Command word parity bit to 0.
SEARCH:SEARCH1:TRIGger:A:BUS:B1:MIL1553B:COMMAND:PARity?
might return 0, 1 or X.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress
When the MIL-STD-1553 bus search condition is set to COMMAND, this command
specifies the 5 bit sub-address that is to be used in the search. When the
sub-address value is set to 00000 or 11111 binary, it specifies that the command is
a “Mode Code” command. Any other value specifies that it is a “Word Count”
command. The default is all X’s (don’t care).
SEARCH<x> is the search number,
whichisalways1,and
B<x>
NOTE. The sub-address field is used to direct data to different functions within the
subsystem for values 1 — 30.
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:
SUBADdress <QString>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:
SUBADdress?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:CONDition
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:
COUNt
Arguments
QString is a quoted string of up to 5 characters, where the allowable characters are
0, 1, and X.
2-676 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Commands Listed in Alphabetical Order
Examples
SEARCH:SEARCH
1:TRIGger:A:BUS:B1:MIL1553B:COMMAND:
SUBADdress “01000”
sets the sub-address to be used in the search to 01000.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit
When the MIL-STD-1553 bus search condition is set to COMMAND, this command
specifies that the transmit/receive bit (bit 9) is to be used in the search. The
transmit/receive bit defines the direction of information flow, and is always from
the point of view of the remote terminal.
SEARCH<x> is the search number, which
is always 1, and
B<x>
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit
{RX|TX|X}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:CONDition
SEARCH:SEARCH<
x>:TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:
COUNt
Arguments
RX (logic 0) di
rects the instrument to search for a TX or "transmit" from a remote
terminal .
TX (logic 1) directs the instrument to search for an RX or "receive" from a remote
terminal.
X indicates “don’t care".
Examples
TRIGger:A:BUS:B1:MIL1553B:COMMAND:TRBit TX directs the instrument to
search for a TX or “transmit” from a remote terminal.
TRIGger:A:BUS:B1:MIL1553B:COMMAND:TRBit TX? might return TX.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:CONDition
This command specifies a word type or condition within a MIL-STD-1553 bus
word to search for.
SEARCH<x> is the search number, which is always 1, and B<x>
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-677