Command Groups T able 2-36: Power Commands (cont.) Command Description POWer:HARMonics:RESults: HAR<1-400>:TEST :IEC: CLASSALIMit? Returns P ASS, F AIL or NA. Speci fi es if the IEC Class A higher harmonic limit (an…

Command Groups
Table 2-36: Power Commands (cont.)
Command Description
POWer:HARMonics:FREQRef:
FIXEDFREQValue
This command specifies the fixed reference frequency value for harmonics measurements
POWer:HARMonics:IEC:CLAss This command specifies the filtering class for IEC harmonics
POWer:HARMonics:IEC:FILter This command specifies the enabled state for filtering of IEC harmonics
POWer:HARMonics:IEC:
FUNDamental
This command specifies the fundamental current for IEC harmonics
POWer:HARMonics:IEC:GROUPing This command specifies the enabled state for grouping of IEC harmonics
POWer:HARMonics:IEC:
INPUTPOWer
Sets of returns the class D input power for IEC harmonics
POWer:HARMonics:IEC:
LINEFREQuency
This command specifies the line frequency for the IEC standard
POWer:HARMonics:IEC:
OBSPERiod
This command speci fies the IEC observation period
POWer:HARMonics:IEC:
POWERFACtor
This command specifies the power factor for IEC harmonics
POWer:HARMonics:MIL:
FUNDamental:CALCmethod
This command specifies the m easurement method for the MIL harmonics fundamental
frequency
POWer:HARMonics:MIL:
FUNDamental:USER:CURrent
This command specifies RMS amperes for User calculation method
POWer:HARMonics:MIL:
LINEFREQuency
This command specifies the line frequency for MIL-STD-1399 Section 300A harmonics tests
POWer:HARMonics:MIL:
POWERLEVel
This command specifies the power level for MIL-STD-1399 Section 300A harmonics tests
POWer:HARMonics:NR_HARMonics Sets of returns the number of harmonics (a value i n the range of 20 to 400) when the
harmonics standard is NONe
POWer:HARMonics:RESults:
HAR<1-400>:FREQuency?
Returns the frequency of the harmonic
POWer:HARMonics:RESults:
HAR<1-400>:IECMAX?
The IEC standard specifi es harmonics measurements to be computed in windows of time,
with each time w indow being nominally 200 ms. This returns the maximum of the RMS
magnitude of the harmonic, computed across successive 200 ms time windows within an
observation period entered by the user
POWer:HARMonics:RESults:
HAR<1-400>:LIMit?
The IEC and MIL standards specify a limit for each harmonic magnitude. Returns the limit
in absolute units, or as a percentage of the fundamental as specified by the standard. IEC
Class C (Table 2) and MIL standards specify the limit as a percentage of the fundamental
POWer:HARMonics:RESults:
HAR<1-400>:PHASe?
Returns the phase of the harmonic in degrees. The phase is measured relative to the
zero-crossing of the reference w aveform. When there is n o reference waveform, the phase
is relative to the fundamental component
POWer:HARMonics:RESults:
HAR<1-400>:RMS:ABSolute?
Returns the RMS magnitude of the harmonic expressed in absolute units
POWer:HARMonics:RESults:
HAR<1-400>:RMS:PERCent?
Returns the RMS magnitude of the harmonic expressed as a percentage of the fundamental
2-42 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Command Groups
Table 2-36: Power Commands (cont.)
Command Description
POWer:HARMonics:RESults:
HAR<1-400>:TEST:IEC:
CLASSALIMit?
Returns PASS, FAIL or NA. Specifies if the IEC Class A higher harmonic limit (and
conditions) are met
POWer:HARMonics:RESults:
HAR<1-400>:TEST:IEC:NORMAL?
Returns PASS, FAIL or NA. Specifies if the Normal IEC harmonic limits are met
POWer:HARMonics:RESults:
HAR<1-400>:TEST:IEC:POHCLIMit?
Returns PASS, FAIL or NA. Specifies if the higher harmonic limit (and conditions) for the 21st
and higher order odd harmonics are m et
POWer:HARMonics:RESults:
HAR<1-400>:TEST:MIL:NORMAL?
Returns the test result for the specified harmonic for the MIL-STD-1399 Section 300A testing
standard
POWer:HARMonics:RESults:IEC:
FUNDamental?
Returns the IEC fundamental frequency
POWer:HARMonics:RESults:IEC:
HARM3ALTernate?
Returns the IE C harmonics test result for the 3rd harmonic: PASS, FA IL or NA
POWer:HARMonics:RESults:IEC:
HARM5ALTernate?
Returns the IEC harmonics test result for the 5th harmonic: PASS, FAIL or NA
POWer:HARMonics:RESults:IEC:
POHC?
Returns the IEC POHC measurement
POWer:HARMonics:RESults:IEC:
POHL?
Returns the IEC POHL measurement
POWer:HARMonics:RESults:IEC:
POWer?
Returns the IEC input power measurement
POWer:HARMonics:RESults:IEC:
POWERFactor?
Returns the IEC power factor measurement
POWer:HARMonics:RESults:
PASSFail?
Returns the overall harmonics test result: PASS, FAIL or NA
POWer:HARMonics:RESults:RMS? Returns the root mean square value of the source waveform
POWer:HARMonics:RESults:SAVe Saves the harmonic results to the specified file in CSV format
POWer:HARMonics:RESults:THDF? Returns the Total Harmonic Distortion (THD) in percentage, measured as a ratio to the RMS
value of the fundamental component of the s ource waveform
POWer:HARMonics:RESults:THDR? Returns the Total Harmonic Distortion ( TH D) in percentage, measured as a ratio to the
RMS value of the source waveform
POWer:HARMonics:SOURce This command specifies the source waveform for harmonics tests
POWer:HARMonics:STANDard This command specifies the standard for harmonics tests
POWer:INDICators This command specifies the state of the measurement indicators for the power application
POWer:MODulation:SOUrce This command specifies the source waveform for modulation tests
POWer:MODulation:TYPe This command specifies the modulation type
POWer:QUALity:APPpwr?
Returns the apparent power measurement
POWer:QUALity:DISplay:APPpwr This command specifies the display state for the apparent power readout
POWer:QUALity:DISplay:
FREQuency
This command specifies the display state for the frequency readout
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-43

Command Groups
Table 2-36: Power Commands (cont.)
Command Description
POWer:QUALity:DISplay:
ICRESTfactor
This command specifies the display state for the c urrent crest factor readout
POWer:QUALity:DISplay:IRMS This command specifies the display state for the rms current (IRMS) readout
POWer:QUALity:DISplay:
PHASEangle
This command specifies the display state for the phase angle readout
POWer:QUALity:DISplay:
POWERFACtor
This command specifies the display state for the power factor readout
POWer:QUALity:DISplay:REACTpwr This command specifies the display state for the reactive power readout
POWer:QUALity:DISplay:TRUEpwr This command specifies the display state for the true power readout
POWer:QUALity:DISplay:
VCRESTfactor
This command specifies the display state for the voltage crest factor readout
POWer:QUALity:DISplay:VRMS This command specifies the display state for the rms voltage (VRMS) readout
POWer:QUALity:FREQREFerence This command specifies the power quality frequency reference
POWer:QUALity:FREQuency? Returns the frequency measurement
POWer:QUALity:ICRESTfactor? Returns the current crest factor measurement
POWer:QUALity:IRMS?
Returns the rms current measurement
POWer:QUALity:PHASEangle?
Returns the phase angle measurement
POWer:QUALity:POWERFACtor? Returns the power factor measurement
POWer:QUALity:REACTpwr?
Returns the reactive power measurement
POWer:QUALity:TRUEpwr?
Returns the true power measurement
POWer:QUALity:VRMS?
Returns the rms voltage measurement
POWer:REFLevel:ABSolute Sets the reference l evels to their default unit values
POWer:REFLevel:ABSolute:HIGH This command specifies the top reference level for rise time
POWer:REFLevel:ABSolute:LOW This command specifies the low reference level for rise time
POWer:REFLevel:ABSolute:MID<x> This command specifies the mid reference level for measurements
POWer:REFLevel:HYSTeresis This command speci fies the m easurement reference level hysteresis value
POWer:REFLevel:METHod This command specifies the method used to calculate the 0% and 100% reference level
POWer:REFLevel:PERCent Sets the reference levels to the default percentage values
POWer:REFLevel:PERCent:HIGH This command specifies the top reference percent level for rise time
POWer:REFLevel:PERCent:LOW This command specifies the low reference percent level for rise time
POWer:REFLevel:PERCent:MID<x> This command specifies the mid reference percent level for waveform measurements
POWer:RIPPle Sets the vertical offset of the source w aveform
POWer:RIPPle:RESults:AMPLitude?
Returns the peak-to-peak ripple measurement
POWer:RIPPle:RESults:MAX? Returns the maximum of the peak-to-peak ripple measurements
POWer:RIPPle:RESults:MEAN? Returns the mean of the peak-to-peak ripple measurements
POWer:RIPPle:RESults:MIN? Returns the minimum of the peak-to-peak ripple measurement
POWer:RIPPle:RESults:STDdev? Returns the standard deviation of the peak-to-peak ripple m easurements
POWer:RIPPle:SOUrce This command specifies the source waveform for ripple tests
2-44 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual