MDO3000 Programmer Manual.pdf - 第76页
Command Groups T able 2-36: Power Commands (cont.) Command Description POWer:SWLoss:GA T e:TURNON This command speci fi es the gate turn on level for switching loss power measurements POWer:SWLoss:NUMCYCles? Returns the n…

Command Groups
Table 2-36: Power Commands (cont.)
Command Description
POWer:SOA:LINear:XMAX This command specifies the user XMAX value for use in linear SOA calculations
POWer:SOA:LINear:XMIN This command specifies the user XMIN value for use in linear SOA calculations
POWer:SOA:LINear:YMAX This command specifies the user YMAX value for use in linear SOA calculations
POWer:SOA:LINear:YMIN This command specifies the user YMIN value for use in linear SOA calculations
POWer:SOA:LOG:XMAX This command specifies the user XMAX value for u se in log SOA calculations
POWer:SOA:LOG:XMIN This command specifies the user XMIN value for use in log SOA calculations
POWer:SOA:LOG:YMAX This command specifies the user YMAX value for u se in log SOA calculations
POWer:SOA:LOG:YMIN This command specifies the user YMIN value for use in log SOA calculations
POWer:SOA:MASK:DEFine This command specifies the X (volts) and Y (Amps) coordinates of the current SOA mask
POWer:SOA:MASK:MAXAmps This command specifies the maximum current applied to SOA mask testing
POWer:SOA:MASK:MAXVolts This command specifi es the maximum voltage applied to SOA mask testing
POWer:SOA:MASK:MAXWatts This command specifies the maximum power applied to SO A mask testing
POWer:SOA:MASK:NR_Pt? Returns the number of mask points defined
POWer:SOA:MASK:STAT E This command specifies the state of the m ask for SO A calculations
POWer:SOA:MASK:STOPOnviol This command specifies the enabled state of the mask stop on violation condition
POWer:SOA:PLOTTYPe This command specifies the SOA plot type
POWer:SOA:RESult:FAILures:QTY? Returns the number of failures in the test
POWer:SOA:RESult:NUMACq? Returns the number of acquisitions in the test
POWer:SOA:RESult:STATE? Returns the pass/fail state o f the SOA test
POWer:STATIstics Clears all the accumulated statistics of all measurements
POWer:STAT Istic s:M ODe Enables or disables the display of the m easurement statistics
POWer:STATIstics:WEIghting Sets the number of samples which are included for the statistics computations for m ean
and the standard deviation
POWer:SWLoss:
CONDCALCmethod
This command specifies the power application switching loss conduction calculation m ethod
POWer:SWLoss:CONDuction:
ENERGY:MAX?
Returns the maximum conduction energy for the switching loss calculation
POWer:SWLoss:CONDuction:
ENERGY:MEAN?
Returns the mean conduction energy for the switching loss calculation
POWer:SWLoss:CONDuction:
ENERGY:MIN?
Returns the minimum conduction energy for the switching loss calculation
POWer:SWLoss:CONDuction:
POWer:MAX?
Returns the maximum conduction power for the switching loss calculation
POWer:SWLoss:CONDuction:
POWer:MEAN?
Returns the mean conduction power for the switching loss calculation
POWer:SWLoss:CONDuction:
POWer:MIN?
Returns the minimum conduction power for the switching loss calculation
POWer:SWLoss:DISplay This command specifies the display selection for switching loss results
POWer:SWLoss:GATe:PO Larity This command specifies the switching loss gate polarity
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-45

Command Groups
Table 2-36: Power Commands (cont.)
Command Description
POWer:SWLoss:GATe:TURNON This command speci fies the gate turn on level for switching loss power measurements
POWer:SWLoss:NUMCYCles? Returns the number of cycles counted for the switching loss calculation
POWer:SWLoss:RDSon This command specifies RDSON value for use in switching loss calculations when the
conduction calculation method is RDSON
POWer:SWLoss:REFLevel:
ABSolute:GATE Mid
This command specifies the mid voltage reference level used in switching loss power
measurements in v olts
POWer:SWLoss:REFLevel:
ABSolute:LOWCurrent
This command specifies the low current reference level used in switching loss power
measurements in amperes
POWer:SWLoss:REFLevel:
ABSolute:LOWVoltage
This command speci fies the low voltage reference level used in switching loss power
measurements in v olts
POWer:SWLoss:REFLevel:
PERCent:GATEMid
This command specifies the mid voltage reference level used in switching loss power
measurements in percentage
POWer:SWLoss:REFLevel:
PERCent:LOWCurrent
This command specifies the low current reference level used in switching loss power
measurements in percentage
POWer:SWLoss:REFLevel:
PERCent:LOWVoltage
This command speci fies the low voltage reference level used in switching loss power
measurements in percentage
POWer:SWLoss:TOFF:ENERGY:
MAX?
Returns the maximum Toff energy switching loss calculation
POWer:SWLoss:TOFF:ENERGY:
MEAN?
Returns the mean To ff energy switching loss calculation
POWer:SWLoss:TOFF:ENERGY:
MIN?
Returns the minimum Toff energy switching loss calculation
POWer:SWLoss:TOFF:POWer:
MAX?
Returns the maximum Toff power switching loss calculation
POWer:SWLoss:TOFF:POWer:
MEAN?
Returns the mean Toff power switching loss calculation
POWer:SWLoss:TOFF:POWer:MIN? Returns the minimum Toff power switching loss calculation
POWer:SWLoss:TON:ENERGY:
MAX?
Returns the maximum Ton energy switching loss calculation
POWer:SWLoss:TON:ENERGY:
MEAN?
Returns the mean Ton energy switching loss c alculation
POWer:SWLoss:TON:ENERGY:
MIN?
Returns the minimum Ton energy switching loss c alculation
POWer:SWLoss:TON:POWer:MAX?
Returns the maximum Ton power switching loss calculation
POWer:SWLoss:TON:POWer:
MEAN?
Returns the mean Ton power switching loss calculation
POWer:SWLoss:TON:POWer:MIN?
Returns the minimum Ton power switching loss calculation
POWer:SWLoss:TOTal:ENERGY:
MAX?
Returns the maximum total energy switching loss calculation
POWer:SWLoss:TOTal:ENERGY:
MEAN?
Returns the mean total energy switching loss calculation
2-46 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Command Groups
Table 2-36: Power Commands (cont.)
Command Description
POWer:SWLoss:TOTal:ENERGY:
MIN?
Returns the minimum total energy switching loss calculation
POWer:SWLoss:TOTal:POWer:
MAX?
Returns the maximum total power switching loss calculation
POWer:SWLoss:TOTal:POWer:
MEAN?
Returns the mean total power switching loss c alculation
POWer:SWLoss:TOTal:POWer:MIN?
Returns the minimum total power switching loss calculation
POWer:SWLoss:VCEsat This command specifi es VCESAT value for use in switching loss calculations when the
conduction calculation method is VCESAT
POWer:TYPe This command specifies the power application measurement type
POWer:VOLTA GESOurce This command speci fies the voltage source for the power application
RF Command Group
The Tektronix MDO4000/B Series Oscilloscope models, MDO4000C models with
option SA3 or SA6, and MDO3000 models have a built-in RF input, in addition to
analog and digital channels, which allows you to display, measure, performmath
on and analyze both time and frequency domain signals with one instrument.
The MDO4000/B and MDO4000C models with option SA3 or SA6 combine
the fun
ctionality of a mid-range oscilloscope and a standard spectrum analyzer,
which makes it able to provide several time-correlated display and measurement
options for RF traces.
The MDO3000 allows frequency domain measurements but does not offer
time-correlated display and measurement options for RF traces.
The RF commands are concentrated in the RF Command Group, but also appear
in other command groups, including Save and Recall, Waveform Transfer, Trigger
and Search. A table is available that links the RF features to their corresponding
commands, regardless of command group. (See page 1-2, New or Changed
Functionality Updates that Impact the Programmatic Command Set.)
Frequency Domain Trace
Types
The MDO4000/B/C and MDO3000 support four frequency waveform types:
The frequency domain window provides support for four spectrum traces, which
may be turned on and off independently.
1. RF Normal trace: Each acquisition is discarded as new data is acquired.
2. RF Max Hold trace: The maximum data values are accumulated over multiple
acquisitions of the RF Normal trace.
3. RF Min Hold trace: The minimum data values are accumulated over multiple
acquisitions of the RF Normal trace.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-47