Commands Listed in Alphabetical Order
Conditions
This command re
quires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:ETHERnet:MAC:ADDRess:SOUrce:VALue
<QString>
TRIGger:A:BUS:B<x>:ETHERnet:MAC:ADDRess:SOUrce:VALue?
Related Commands
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
TRIGger:A:BUS:B<x>:ETHERnet:MAC:ADDRess:DESTination:VALue
Arguments
QString is a quoted string of up to 48 characters where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
Examples
TRIGger:A:BUS:B1:ETHERnet:MAC:ADDRess:SOUrce:VALue
XXXXXXXXXX01010111111100000001111010101010101000 would set the
MAC destination address to trigger on to XX:35:FC:07:AA:C8 hex.
TRIGger:A:BUS:B1:ETHERnet:MAC:ADDRess:SOUrce:VALue? might
return XXXXXXXXXX01010111111100000001111010101010101000.
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:TYPe}:HIVALue
When the Ethernet trigger condition is set to MACLENgth, and the qualifier is set
to
INrange or OUTrange, this command specifies the upper data value of the
range. (Use the command TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:
TYPe}:VALue to specify the lower limit of the range.) The default is all X’s
(don’t care).
B<x> is the bus number B1-B4.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:TYPe}:HIVALue
<QString>
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:TYPe}:HIVALue?
2-802 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual
Commands Listed in Alphabetical Order
Related Commands
TRIGger:A:BUS
:B<x>:ETHERnet:CONDition
TRIGger:A:BUS:B<x>:ETHERnet:QUALifier
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:TYPe}:VALue
Arguments
QString is a quoted string of up toe 16 characters where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
Examples
TRIGger:A:BUS:B1:ETHERnet:MAC{:LENgth|:TYPe}:HIVALue
“XXXXXXXX00001000” sets the upper limit of the range to the hexadecimal
value XX08 (when the trigger condition is set to
MACLENgth, and the qualifier is
set to
INrange or OUTr ange).
TRIGGER:A:BUS:B1:ETHERNET:MAC{:LENGTH|:TYPE}:HIVALUE?
might
return “XXXXXXXX00001000”.
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:TYPe}:VALue
When the Ethernet trigger condition is set to MACLENgth , and the qualifier is set
to
LESSthan, MOREthan, EQual, UNEQual, LESSEQual or MOREEQual,
this command specifies the 16–bit value to trigger on. When the qualifier is set
to
INrange or OUTrange, this command specifies the lower limit of the range.
(Use the command TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:TYPe}:
HIVALue to set the upper limit of the range.) The default is all X’s (don’t care).
B<x> is the bus number B1-B4.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:TYPe}:VALue
<QString>
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:TYPe}:VALue?
Related Commands
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
TRIGger:A:BUS:B<x>:ETHERnet:QUALifier
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:TYPe}:HIVALue
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-803
Commands Listed in Alphabetical Order
Arguments
QString is a quo
ted string of up to 16 characters where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
Examples
TRIGger:A:BUS:B1:ETHERnet:MAC{:LENgth|:TYPe}:VALue
“XXXXXXXX00001000”
sets the MAC length/type value to trigger on the
hexadecimal value XX08, assuming the qualifier is set to
LESSthan,
MOREthan, EQual, UNEQual, LESSEQual
or MOREEQual.
TRIGger:A:BUS:B1:ETHERnet:MAC{:LENgth|:TYPe}:VALue
“XXXXXXXX00001000”
sets the lower limit of the range to the hexadecimal value
XX08, assuming the qualifier is set to
INrange or OUTrange.
TRIGger:A:BUS:B<x>:ETHERnet:QTAG:VALue
When the Ethernet trigger condition is set to QTAG, this command specifies the
32–bit Q-Tag value to trigger on. The default is all X’s (don’t care).
B<x> is
the bus number B1-B4.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:ETHERnet:QTAG:VALue <QString>
TRIGger:A:BUS:B<x>:ETHERnet:QTAG:VALue?
Related Commands
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
Arguments
QString is a quoted string of up to 32 characters where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
Examples
TRIGGER:A:BUS:B1:ETHERNET:QTAG:VALUE
“XXXXXXXXXXXXXXXXXXXX010010001010” would specify to trigger
on the Q-Tag value of hexadecimal XXXXX48A.
TRIGGER:A:BUS:B1:ETHERNET:QTAG:VALUE? might return
"XXXXXXXXXXXXXXXXXXXX010010001010".