Commands Listed in Alphabetical Order Examples TRIGger:A:BUS :B1:ETHERnet:TCP Header:DESTinati onport:VALue “XXXXXXXX0010 0010” would set the destination port address value that is to be used in the trigger to hexadecim …

100%1 / 1158
Commands Listed in Alphabetical Order
Syntax
TRIGger:A:BUS
:B<x>:ETHERnet:TCPHeader:ACKnum:VALue <QString>
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:ACKnum:VALue?
Related Commands
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SOUrceport:VALue
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SEQnum:VALue
Arguments
QString is a quoted string of up to 32 characters where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
Examples
TRIGger:A:BUS:B1:ETHERnet:TCPHeader:ACKnum:VALue
“XXXXXXXXXXXXXXXXXXXX00001000
sets the acknowledgement number to
be used in the trigger to hexadecimal XXXXXX08.
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue
When the Ethernet trigger condition is set TCPHeader, this command specifies
the 16–bit destination port address value that is to be used in the trigger (along
with the acknowledgement value, source port address and the sequence number).
The default is all X’s (don’t care).
B<x> is the bus number B1-B4.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue
<QString>
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue?
Related Commands
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:ACKnum:VALue
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SOUrceport:VALue
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SEQnum:VALue
Arguments
QString is a quoted string of up to 16 characters where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
2-806 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual
Commands Listed in Alphabetical Order
Examples
TRIGger:A:BUS
:B1:ETHERnet:TCPHeader:DESTinationport:VALue
“XXXXXXXX00100010”
would set the destination port address value that is to be
used in the trigger to hexadecimal XX22.
TRIGger:A:BUS:B1:ETHERnet:TCPHeader:DESTinationport:VALue?
might return “XXXXXXXXXXXXXXXX”.
TRIGger:A:
BUS:B<x>:ETHERnet:TCPHeader:SEQnum:VALue
When the Ethernet trigger condition is set to TCPHeader, this command specifies
the 32–bit sequence number that is to be used in the trigger (along with the
destinat
ion and source port addresses and the acknowledgement value). The
default is all X’s (don’t care).
B<x> is the bus number B1-B4.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SEQnum:VALue <QString>
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SEQnum:VALue?
Related Commands
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:ACKnum:VALue
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SOUrceport:VALue
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue
Arguments
QString is a quoted string of up to 32 characters where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
Examples
TRIGger:A:BUS:B1:ETHERnet:TCPHeader:SEQnum:VALue
“XXXXXXXXXXXXXXXXXXXX000100010001”
would set the sequence number
that is to be used in the trigger to hexadecimal XXXXX111.
TRIGger:A:BUS:B1:ETHERnet:TCPHeader:SEQnum:VALue? might return
"XXXXXXXXXXXXXXXXXXXXXX0010010100" .
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-807
Commands Listed in Alphabetical Order
TRIGger:A:BU
S:B<x>:ETHERnet:TCPHeader:SOUrceport:VALue
When the Ethernet trigger condition is set to TCPHeader, this command specifies
the 16–bit source port address that is to be used in the trigger (along with the
destination
port address, the sequence number and the acknowledgement number).
The default is all X’s (don’t care).
B<x> is the bus number B1-B4.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SOUrceport:VALue
<QString>
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SOUrceport:VALue?
Related Commands
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:ACKnum:VALue
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SEQnum:VALue
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue
Arguments
QString is a quoted string of up to 16 characters where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
Examples
TRIGger:A:BUS:B1:ETHERnet:TCPHeader:SOUrceport:VALue
“XXXX000010100110” would set the source port address that is to be used in the
trigger to hexadecimal X0A6.
TRIGger:A:BUS:B1:ETHERnet:TCPHeader:SOUrceport:VALue? might
return “XXXXX01001010110”.
TRIGger:A:BUS:B<x>:FLEXray:CONDition
This command specifies the condition to use when triggering on a FlexRay bus
signal (start of frame, frame t
ype, ID, cycle count, header, data, ID and data,
EOF, error).
B<x> is the bus number B1-B4, except for MDO3000, which has
two buses B1–B2..
2-808 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual